- MeSH
- biologické markery * analýza MeSH
- chybná diagnóza MeSH
- diagnostické techniky gastrointestinální klasifikace trendy MeSH
- ELISA MeSH
- feces * mikrobiologie MeSH
- gastrointestinální nemoci diagnostické zobrazování klasifikace MeSH
- lidé MeSH
- metody pro přípravu analytických vzorků metody MeSH
- odběr biologického vzorku metody MeSH
- pracovníci laboratoře MeSH
- prediktivní hodnota testů MeSH
- senzitivita a specificita MeSH
- Check Tag
- lidé MeSH
We report on a Lab-On-Valve (LOV) configuration for analyte preconcentration from milliliter sample volumes using confluent mixing in the holding coil for in-line addition of loading buffer. The system was applied to the spectrophotometric determination of iron(II) in acidified seawater using 1,10-phenanthroline as color reagent. A cellulose-based chelating sorbent containing 8-hydroxyquinoline was used for the first time in LOV and excellent retention behavior and loading capacity were found. The flow system employs a syringe pump for handling all solutions (sorbent suspension, loading buffer, water, eluent, and color reagent) and a peristaltic pump for sample propulsion and includes a fit-for-purpose 14 cm long detection glass flow cell and a bubble trap for in-line carrier degasification. Advantage was taken of the LOV flow-through port to keep the eluted analytes for re-aspiration for subsequent chromogenic reaction. In effect, a universal analyzer configuration and preconcentration procedure was developed, which is combinable with other analytes, sorbents, and reagents. Among the studied parameters were the compositions, pH, volumes, and flow rates of loading buffer, eluent, and color reagent, as well as the microcolumn size, repeatability, and system stability. Reproducibility of 4.1% RSD over the entire working range, a LOD of down to 5 nmol L(-1), sampling frequency of 12h(-1), and linearity up to 1 µmol L(-1) for 3.3 mL of sample were obtained and applicability to real samples was demonstrated. It was proven that both Fe(III) and Fe(II) were retained and yielded similar recovery and sensitivity values. The method was applied to coastal seawater samples and spiking experiments yielded recovery values close to 100%.
- MeSH
- barva MeSH
- celulosa chemie MeSH
- chelátory chemie MeSH
- extrakce na pevné fázi MeSH
- fenantroliny chemie MeSH
- koncentrace vodíkových iontů MeSH
- limita detekce * MeSH
- metody pro přípravu analytických vzorků přístrojové vybavení metody MeSH
- mořská voda chemie MeSH
- oxychinolin chemie MeSH
- pufry MeSH
- reprodukovatelnost výsledků MeSH
- železo analýza chemie izolace a purifikace MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Biomolecular simulations are routinely used in biochemistry and molecular biology research; however, they often fail to match expectations of their impact on pharmaceutical and biotech industry. This is caused by the fact that a vast amount of computer time is required to simulate short episodes from the life of biomolecules. Several approaches have been developed to overcome this obstacle, including application of massively parallel and special purpose computers or non-conventional hardware. Methodological approaches are represented by coarse-grained models and enhanced sampling techniques. These techniques can show how the studied system behaves in long time-scales on the basis of relatively short simulations. This review presents an overview of new simulation approaches, the theory behind enhanced sampling methods and success stories of their applications with a direct impact on biotechnology or drug design.
Vydání první 185 stran : ilustrace, tabulky ; 21 cm
Monografie pojednává o problematice nelegálních návykových látek v silniční dopravě. Obliba užívání drog v populaci se logicky promítá i do situace v silniční dopravě v podobě zvýšeného počtu řidičů řídících vozidlo pod vlivem návykové látky a zvýšeného počtu nehod zaviněných těmito řidiči. Autor analyzuje situace při řešení tohoto problému policií a dalšími odpovědnými orgány a uvádí komplikace s eliminací tohoto celospolečenského negativního jevu.
- MeSH
- chemické techniky analytické metody přístrojové vybavení využití MeSH
- kriminologie MeSH
- metody pro přípravu analytických vzorků metody přístrojové vybavení využití MeSH
- policie MeSH
- poruchy spojené s užíváním psychoaktivních látek MeSH
- řízení motorových vozidel zákonodárství a právo MeSH
- Publikační typ
- monografie MeSH
- Konspekt
- Kriminologie
- NLK Obory
- právo, zákonodárství
- adiktologie
The aim of the study was to establish and optimize an electrochemical method for the assay of low-molecular-weight antioxidants (LMWA). We used square-wave vol¬tammetry (at 01.1 V) on screen-printed sensors with C working electrodes. Optimum parameters were: potential step and amplitude 5 mV and frequency 1 Hz. Ascorbic acid, trolox, N-acetylcysteine and melatonin were used as standard antioxidants to test the linearity and sensitivity of the method. Limits of detection were 0.09 mmol l1 for ascorbic acid, 0.04 mmol l1 for melatonin, 0.03 mmol l1 for trolox, and 0.07 mmol l1 for N-acetylcysteine. 20 ??????l samples were used. The suitability of the method for the assay was confirmed by the standard ferric reducing ability of plasma test. Both methods correlated well (correlation coefficient 0.9778).
- MeSH
- antioxidancia * analýza MeSH
- chemické techniky analytické metody přístrojové vybavení využití MeSH
- cystein analýza krev MeSH
- elektrochemické techniky * metody přístrojové vybavení využití MeSH
- glutathion analýza krev MeSH
- krevní plazma * MeSH
- kyselina askorbová * analýza krev MeSH
- kyselina močová analýza krev MeSH
- lidé MeSH
- melatonin analýza krev MeSH
- metody pro přípravu analytických vzorků metody přístrojové vybavení MeSH
- oxidační stres MeSH
- reaktivní formy kyslíku chemie MeSH
- tokoferoly analýza krev MeSH
- vitamin A analýza krev MeSH
- volné radikály chemie MeSH
- Check Tag
- lidé MeSH
The liposoluble vitamins (retinol and α-tocopherol) concentration in human breast milk is of a cardinal knowledge especially for nutrition of prematurely born. It enables the feeding optimization of these important micronutrients for preterm infants. The novel rapid liquid-liquid extraction procedure for human breast milk investigation was developed and validated according to FDA guidelines. The recovery of retinol was 82-90% measured at three concentration levels 1.0, 2.5 and 5.0 μmol/L, for α-tocopherol 92-109% at concentration levels 2.5, 5.0 and 10.0 μmol/L. The repeatability of extraction procedure expressed as relative standard deviation was 3.26% for retinol and 4.79% for α-tocopherol. Developed extraction procedure was applied on 120 human breast milk samples. The separation of vitamins was completed using advantages of a monolithic column which accomplished demands of acceleration made by modern bio-analytical HPLC methodology. The analytes of interest were detected by diode-array detector at wavelengths 325 nm for retinol and 290 nm for α-tocopherol.
- MeSH
- alfa-tokoferol analýza izolace a purifikace MeSH
- časové faktory MeSH
- dospělí MeSH
- indikátory a reagencie chemie MeSH
- lidé MeSH
- mateřské mléko chemie MeSH
- metody pro přípravu analytických vzorků metody MeSH
- mléčné bílkoviny chemie izolace a purifikace MeSH
- reprodukovatelnost výsledků MeSH
- vitamin A analýza izolace a purifikace MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8-fold.
- MeSH
- amfolytové směsi MeSH
- biologické přípravky chemie izolace a purifikace MeSH
- isoelektrická fokusace přístrojové vybavení metody MeSH
- koncentrace vodíkových iontů MeSH
- kvasinky chemie MeSH
- metody pro přípravu analytických vzorků přístrojové vybavení metody MeSH
- proteiny chemie izolace a purifikace MeSH
- pšenice chemie MeSH
- rostlinné extrakty chemie izolace a purifikace MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A study of complex protein mixtures obtained from biological samples by MS demands proper purification and separation technique. The method of divergent flow isoelectric focusing (DF IEF) promises improvement of sample preparation in proteomic studies. DF IEF was carried out in a separation channel with increasing width. The channel was cut out from a polyester nonwoven web. DC voltage (800 V) was brought to two pairs of electrodes situated on the channel sides. Amphoteric compounds, including proteins, drift through the channel carried by flow (18-25 ml/h) in streamlines given by their isoelectric points. The pH gradient (3-10) and its stability during analysis have been monitored with colored low-molecular mass pI markers. Separated fractions were collected in ten microvials and further analyzed by MS. The suggested method was used for separation and purification of crude protein extract from barley grain, malt, and beer. Collected fractions of separated proteins were characterized by MALDI-MS. Desalting during IEF enhanced significantly the quality of mass spectra. It also simplified monitoring of post-translational modifications and protein changes occurring during malting and brewing. Results have shown the real potential of the suggested DF IEF device lay-out as an efficient preparative tool for separation and purification of complex protein mixtures for further analyses.
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrody MeSH
- financování organizované MeSH
- isoelektrická fokusace metody přístrojové vybavení MeSH
- koncentrace vodíkových iontů MeSH
- metody pro přípravu analytických vzorků metody MeSH
- molekulová hmotnost MeSH
- proteiny analýza MeSH
- proteomika MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice metody přístrojové vybavení MeSH
Acta hygienica, epidemiologica et microbiologica, ISSN 0862-5956 Příl. č. 8/ 1991
16 s. : tab. ; 21 cm
- MeSH
- Aeromonas hydrophila izolace a purifikace MeSH
- bakteriologické techniky metody normy MeSH
- Campylobacter jejuni izolace a purifikace MeSH
- metody pro přípravu analytických vzorků metody normy MeSH
- Yersinia enterocolitica izolace a purifikace MeSH
- Publikační typ
- směrnice MeSH
- Konspekt
- Mikrobiologie
- NLK Obory
- chemie, klinická chemie
- bakteriologie
- hygiena
Acta hygienica, epidemiologica et microbiologica ; příl. č.2/1989
8 s. ; 29 cm
- MeSH
- blízká infračervená spektroskopie metody normy přístrojové vybavení využití MeSH
- chemické techniky analytické metody normy přístrojové vybavení využití MeSH
- křemen analýza MeSH
- krystalografie rentgenová metody normy přístrojové vybavení využití MeSH
- metody pro přípravu analytických vzorků metody normy MeSH
- prach analýza MeSH
- pracovní expozice MeSH
- Publikační typ
- směrnice MeSH
- Konspekt
- Chemie. Mineralogické vědy
- NLK Obory
- environmentální vědy
- chemie, klinická chemie