Je něco špatně v tomto záznamu ?
Preparative divergent flow IEF without carrier ampholytes for separation of complex biological samples
M. Stastna, K. Slais
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
20119953
DOI
10.1002/elps.200900484
Knihovny.cz E-zdroje
- MeSH
- amfolytové směsi MeSH
- biologické přípravky chemie izolace a purifikace MeSH
- isoelektrická fokusace přístrojové vybavení metody MeSH
- koncentrace vodíkových iontů MeSH
- kvasinky chemie MeSH
- metody pro přípravu analytických vzorků přístrojové vybavení metody MeSH
- proteiny chemie izolace a purifikace MeSH
- pšenice chemie MeSH
- rostlinné extrakty chemie izolace a purifikace MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8-fold.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12025246
- 003
- CZ-PrNML
- 005
- 20130222224713.0
- 007
- ta
- 008
- 120816s2010 gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.200900484 $2 doi
- 035 __
- $a (PubMed)20119953
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Šťastná, Miroslava $7 xx0137995 $u Institute of Analytical Chemistry of the ASCR, Brno, Czech Republic. stastna@iach.cz
- 245 10
- $a Preparative divergent flow IEF without carrier ampholytes for separation of complex biological samples / $c M. Stastna, K. Slais
- 520 9_
- $a Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8-fold.
- 650 _2
- $a amfolytové směsi $7 D000665
- 650 _2
- $a metody pro přípravu analytických vzorků $x přístrojové vybavení $x metody $7 D053000
- 650 _2
- $a biologické přípravky $x chemie $x izolace a purifikace $7 D001688
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a isoelektrická fokusace $x přístrojové vybavení $x metody $7 D007525
- 650 _2
- $a rostlinné extrakty $x chemie $x izolace a purifikace $7 D010936
- 650 _2
- $a proteiny $x chemie $x izolace a purifikace $7 D011506
- 650 _2
- $a pšenice $x chemie $7 D014908
- 650 _2
- $a kvasinky $x chemie $7 D015003
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šlais, Karel $7 xx0071057
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 31, č. 3 (2010), s. 433-439
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20119953 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120816 $b ABA008
- 991 __
- $a 20130222224914 $b ABA008
- 999 __
- $a ok $b bmc $g 947288 $s 782592
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 31 $c 3 $d 433-439 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20120816/10/02