• Something wrong with this record ?

Large volume preconcentration and determination of nanomolar concentrations of iron in seawater using a renewable cellulose 8-hydroquinoline sorbent microcolumn and universal approach of post-column eluate utilization in a Lab-on-Valve system

B. Horstkotte, P. Chocholouš, P. Solich,

. 2016 ; 150 (-) : 213-23. [pub] 20151218

Language English Country Netherlands

Document type Journal Article, Research Support, Non-U.S. Gov't

We report on a Lab-On-Valve (LOV) configuration for analyte preconcentration from milliliter sample volumes using confluent mixing in the holding coil for in-line addition of loading buffer. The system was applied to the spectrophotometric determination of iron(II) in acidified seawater using 1,10-phenanthroline as color reagent. A cellulose-based chelating sorbent containing 8-hydroxyquinoline was used for the first time in LOV and excellent retention behavior and loading capacity were found. The flow system employs a syringe pump for handling all solutions (sorbent suspension, loading buffer, water, eluent, and color reagent) and a peristaltic pump for sample propulsion and includes a fit-for-purpose 14 cm long detection glass flow cell and a bubble trap for in-line carrier degasification. Advantage was taken of the LOV flow-through port to keep the eluted analytes for re-aspiration for subsequent chromogenic reaction. In effect, a universal analyzer configuration and preconcentration procedure was developed, which is combinable with other analytes, sorbents, and reagents. Among the studied parameters were the compositions, pH, volumes, and flow rates of loading buffer, eluent, and color reagent, as well as the microcolumn size, repeatability, and system stability. Reproducibility of 4.1% RSD over the entire working range, a LOD of down to 5 nmol L(-1), sampling frequency of 12h(-1), and linearity up to 1 µmol L(-1) for 3.3 mL of sample were obtained and applicability to real samples was demonstrated. It was proven that both Fe(III) and Fe(II) were retained and yielded similar recovery and sensitivity values. The method was applied to coastal seawater samples and spiking experiments yielded recovery values close to 100%.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17000540
003      
CZ-PrNML
005      
20170117122434.0
007      
ta
008      
170103s2016 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2015.12.044 $2 doi
024    7_
$a 10.1016/j.talanta.2015.12.044 $2 doi
035    __
$a (PubMed)26838402
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Horstkotte, Burkhard $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University in Prague, Czech Republic. Electronic address: Horstkob@faf.cuni.cz.
245    10
$a Large volume preconcentration and determination of nanomolar concentrations of iron in seawater using a renewable cellulose 8-hydroquinoline sorbent microcolumn and universal approach of post-column eluate utilization in a Lab-on-Valve system / $c B. Horstkotte, P. Chocholouš, P. Solich,
520    9_
$a We report on a Lab-On-Valve (LOV) configuration for analyte preconcentration from milliliter sample volumes using confluent mixing in the holding coil for in-line addition of loading buffer. The system was applied to the spectrophotometric determination of iron(II) in acidified seawater using 1,10-phenanthroline as color reagent. A cellulose-based chelating sorbent containing 8-hydroxyquinoline was used for the first time in LOV and excellent retention behavior and loading capacity were found. The flow system employs a syringe pump for handling all solutions (sorbent suspension, loading buffer, water, eluent, and color reagent) and a peristaltic pump for sample propulsion and includes a fit-for-purpose 14 cm long detection glass flow cell and a bubble trap for in-line carrier degasification. Advantage was taken of the LOV flow-through port to keep the eluted analytes for re-aspiration for subsequent chromogenic reaction. In effect, a universal analyzer configuration and preconcentration procedure was developed, which is combinable with other analytes, sorbents, and reagents. Among the studied parameters were the compositions, pH, volumes, and flow rates of loading buffer, eluent, and color reagent, as well as the microcolumn size, repeatability, and system stability. Reproducibility of 4.1% RSD over the entire working range, a LOD of down to 5 nmol L(-1), sampling frequency of 12h(-1), and linearity up to 1 µmol L(-1) for 3.3 mL of sample were obtained and applicability to real samples was demonstrated. It was proven that both Fe(III) and Fe(II) were retained and yielded similar recovery and sensitivity values. The method was applied to coastal seawater samples and spiking experiments yielded recovery values close to 100%.
650    _2
$a metody pro přípravu analytických vzorků $x přístrojové vybavení $x metody $7 D053000
650    _2
$a pufry $7 D002021
650    _2
$a celulosa $x chemie $7 D002482
650    _2
$a chelátory $x chemie $7 D002614
650    _2
$a barva $7 D003116
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a železo $x analýza $x chemie $x izolace a purifikace $7 D007501
650    12
$a limita detekce $7 D057230
650    _2
$a oxychinolin $x chemie $7 D015125
650    _2
$a fenantroliny $x chemie $7 D010618
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a mořská voda $x chemie $7 D012623
650    _2
$a extrakce na pevné fázi $7 D052616
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Chocholouš, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University in Prague, Czech Republic.
700    1_
$a Solich, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University in Prague, Czech Republic.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 150, č. - (2016), s. 213-23
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26838402 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170103 $b ABA008
991    __
$a 20170117122540 $b ABA008
999    __
$a ok $b bmc $g 1179680 $s 961107
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 150 $c - $d 213-23 $e 20151218 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20170103

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...