Something wrong with this record ?
Evaluation of the novel passive sampler for cyanobacterial toxins microcystins under various conditions including field sampling
J. Kohoutek, B. Marsálek, L. Bláha,
Language English Country Germany
Document type Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Bacterial Toxins isolation & purification MeSH
- Calibration MeSH
- Membranes, Artificial MeSH
- Microcystins isolation & purification MeSH
- Environmental Monitoring instrumentation MeSH
- Marine Toxins isolation & purification MeSH
- Cyanobacteria chemistry MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Research Support, Non-U.S. Gov't MeSH
In the present study, we have evaluated the effectiveness of a passive sampler for polar organic chemicals to accumulate a group of widespread and hazardous tumor-promoting toxins produced in cyanobacterial water blooms-microcystins (MC). The previously optimized configuration of the sampler based on polycarbonate membrane and Oasis HLB sorbent (2.75 mg/cm(2)) was validated under various exposure scenarios in laboratory and field. Calibration of the passive sampler conducted under variable conditions and concentrations of MC revealed linearity of the sampling up to 4 weeks. The sampling rates of microcystins for two different exposure scenarios were derived (e.g., MC-LR: R (s) = 0.017 L/day under static and 0.087 L/d under turbulent conditions). R (s) values were further used for calculations of time-weighted average concentrations in natural water. Improved sensitivity and selectivity of the in-house-made sampler was observed in comparison with the commercially available Polar Organic Compound Integrative Sampler (POCIS). Comparisons of grab and passive sampling methods were performed during cyanobacterial water bloom season in the Brno reservoir, Czech Republic in 2008. Data obtained by passive sampling provided a more relevant picture of the situation and enabled better assessment of potential risks. The present study demonstrated that the modification of POCIS is suitable for monitoring of occurrence and retrospective estimations of microcystin water concentrations, especially with respect to the control of drinking water quality.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12025878
- 003
- CZ-PrNML
- 005
- 20170511144906.0
- 007
- ta
- 008
- 120817s2010 gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-010-3578-y $2 doi
- 035 __
- $a (PubMed)20225057
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Kohoutek, Jiří $u Institute of Botany, The Academy of Sciences of the Czech Republic, Lidická 25/27, 657 20, Brno, Czech Republic. jiri.kohoutek@recetox.muni.cz $7 xx0081824
- 245 10
- $a Evaluation of the novel passive sampler for cyanobacterial toxins microcystins under various conditions including field sampling / $c J. Kohoutek, B. Marsálek, L. Bláha,
- 520 9_
- $a In the present study, we have evaluated the effectiveness of a passive sampler for polar organic chemicals to accumulate a group of widespread and hazardous tumor-promoting toxins produced in cyanobacterial water blooms-microcystins (MC). The previously optimized configuration of the sampler based on polycarbonate membrane and Oasis HLB sorbent (2.75 mg/cm(2)) was validated under various exposure scenarios in laboratory and field. Calibration of the passive sampler conducted under variable conditions and concentrations of MC revealed linearity of the sampling up to 4 weeks. The sampling rates of microcystins for two different exposure scenarios were derived (e.g., MC-LR: R (s) = 0.017 L/day under static and 0.087 L/d under turbulent conditions). R (s) values were further used for calculations of time-weighted average concentrations in natural water. Improved sensitivity and selectivity of the in-house-made sampler was observed in comparison with the commercially available Polar Organic Compound Integrative Sampler (POCIS). Comparisons of grab and passive sampling methods were performed during cyanobacterial water bloom season in the Brno reservoir, Czech Republic in 2008. Data obtained by passive sampling provided a more relevant picture of the situation and enabled better assessment of potential risks. The present study demonstrated that the modification of POCIS is suitable for monitoring of occurrence and retrospective estimations of microcystin water concentrations, especially with respect to the control of drinking water quality.
- 650 _2
- $a bakteriální toxiny $x izolace a purifikace $7 D001427
- 650 _2
- $a kalibrace $7 D002138
- 650 _2
- $a sinice $x chemie $7 D000458
- 650 _2
- $a monitorování životního prostředí $x přístrojové vybavení $7 D004784
- 650 _2
- $a mořské toxiny $x izolace a purifikace $7 D008387
- 650 _2
- $a membrány umělé $7 D008567
- 650 _2
- $a mikrocystiny $x izolace a purifikace $7 D052998
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Marsálek, Blahoslav
- 700 1_
- $a Bláha, Ludek
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 397, č. 2 (2010), s. 823-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20225057 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20170511145244 $b ABA008
- 999 __
- $a ok $b bmc $g 947920 $s 783224
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 397 $c 2 $d 823-8 $e 20100313 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20120817/10/03