-
Je něco špatně v tomto záznamu ?
Statistical characterization of actigraphy data during sleep and wakefulness states
O. Adamec, A. Domingues, T. Paiva, J. M. Sanches
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- aktigrafie přístrojové vybavení metody MeSH
- bdění MeSH
- časové faktory MeSH
- cirkadiánní rytmus MeSH
- design vybavení MeSH
- lidé MeSH
- monitorování fyziologických funkcí přístrojové vybavení metody MeSH
- počítačové komunikační sítě MeSH
- spánek MeSH
- statistické modely MeSH
- telemedicína přístrojové vybavení metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Human activity can be measured with actimetry sensors used by the subjects in several locations such as the wrists or legs. Actigraphy data is used in different contexts such as sports training or tele-medicine monitoring. In the diagnosis of sleep disorders, the actimetry sensor, which is basically a 3D axis accelerometer, is used by the patient in the non dominant wrist typically during an entire week. In this paper the actigraphy data is described by a weighted mixture of two distributions where the weight evolves along the day according to the patient circadian cycle. Thus, one of the distributions is mainly associated with the wakefulness state while the other is associated with the sleep state. Actigraphy data, acquired from 20 healthy patients and manually segmented by trained technicians, is used to characterize the acceleration magnitude during sleep and wakefulness states. Several mixture combinations are tested and statistically validated with conformity measures. It is shown that both distributions can co-exist at a certain time with varying importance along the circadian cycle.
Institute for Systems and Robotics Instituto Superior Técnico Czech Republic
Institute for Systems and Robotics Switzerland
ISTEL Instituto do Sono Cronobiologia e Telemedicina Lisbon Portugal
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12026624
- 003
- CZ-PrNML
- 005
- 20160301085135.0
- 007
- ta
- 008
- 120816s2010 xxu f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1109/iembs.2010.5627774 $2 doi
- 035 __
- $a (PubMed)21097022
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Adamec, Ondřej $7 _AN038891 $u Faculty of Electrical Engineering and Computer Science, Department of Measurement and Control, VSB Technical University of Ostrava, Czech Republic. ondrej.adamec@vsb.cz
- 245 10
- $a Statistical characterization of actigraphy data during sleep and wakefulness states / $c O. Adamec, A. Domingues, T. Paiva, J. M. Sanches
- 520 9_
- $a Human activity can be measured with actimetry sensors used by the subjects in several locations such as the wrists or legs. Actigraphy data is used in different contexts such as sports training or tele-medicine monitoring. In the diagnosis of sleep disorders, the actimetry sensor, which is basically a 3D axis accelerometer, is used by the patient in the non dominant wrist typically during an entire week. In this paper the actigraphy data is described by a weighted mixture of two distributions where the weight evolves along the day according to the patient circadian cycle. Thus, one of the distributions is mainly associated with the wakefulness state while the other is associated with the sleep state. Actigraphy data, acquired from 20 healthy patients and manually segmented by trained technicians, is used to characterize the acceleration magnitude during sleep and wakefulness states. Several mixture combinations are tested and statistically validated with conformity measures. It is shown that both distributions can co-exist at a certain time with varying importance along the circadian cycle.
- 650 _2
- $a aktigrafie $x přístrojové vybavení $x metody $7 D056044
- 650 _2
- $a cirkadiánní rytmus $7 D002940
- 650 _2
- $a počítačové komunikační sítě $7 D003195
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a statistické modely $7 D015233
- 650 _2
- $a monitorování fyziologických funkcí $x přístrojové vybavení $x metody $7 D008991
- 650 _2
- $a spánek $7 D012890
- 650 _2
- $a telemedicína $x přístrojové vybavení $x metody $7 D017216
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a bdění $7 D014851
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Domingues, Alexandre $u Institute for Systems and Robotics / Instituto Superior Técnico, Czech Republic. adomingues@gmail.com
- 700 1_
- $a Paiva, Teresa $u ISTEL, Instituto do Sono, Cronobiologia e Telemedicina, Lisbon, Portugal. paiva.fml.hsm@mail.telepac.pt
- 700 1_
- $a Sanches, J. Miguel $u Institute for Systems and Robotics, Switzerland. jmrs@ist.ul.pt
- 773 0_
- $w MED00180111 $t Conference proceedings ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference $x 1557-170X $g Roč. 2010(2010), s. 2342-2345
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21097022 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120816 $b ABA008
- 991 __
- $a 20160301085148 $b ABA008
- 999 __
- $a ok $b bmc $g 948666 $s 783970
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 2010 $d 2342-2345 $i 1557-170X $m Conference proceedings ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society $n Conf Proc IEEE Eng Med Biol Soc $x MED00180111
- LZP __
- $b NLK122 $a Pubmed-20120816/11/01