Catheter ablation for paroxysmal atrial fibrillation: a randomized comparison between multielectrode catheter and point-by-point ablation

A. Bulava, J. Haniš, D. Sitek, O. Ošmera, D. Karpianus, M. Snorek, K. Rehoušková, F. Toušek, L. Pešl,

. 2010 ; 33 (9) : 1039-1046.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, randomizované kontrolované studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc12026936

INTRODUCTION: Catheter ablation for paroxysmal atrial fibrillation is widely used for patients with drug-refractory paroxysms of arrhythmia. Recently, novel technologies have been introduced to the market that aim to simplify and shorten the procedure. AIM: To compare the clinical outcome of pulmonary vein (PV) isolation using a multipolar circular ablation catheter (PVAC group), with point-by-point PV isolation using an irrigated-tip ablation catheter and the CARTO mapping system (CARTO group; CARTO, Biosense Webster, Diamond Bar, CA, USA). METHODS: Patients with documented PAF were randomized to undergo PV isolation using PVAC or CARTO. Atrial fibrillation (AF) recurrences were documented by serial 7-day Holter monitoring. RESULTS: One hundred and two patients (mean age 58 ± 11 years, 68 men) were included in the study. The patients had comparable baseline clinical characteristics, including left atrial dimensions and left ventricular ejection fraction, in both study arms (PVAC: n = 51 and CARTO: n = 51). Total procedural and fluoroscopic times were significantly shorter in the PVAC group (107 ± 31 minutes vs 208 ± 46 minutes, P < 0.0001 and 16 ± 5 minutes vs 28 ± 8 minutes, P < 0.0001, respectively). The AF recurrence was documented in 23% and 29% of patients in the PVAC and CARTO groups, respectively (P = 0.8), during the mean follow-up of 200 ± 13 days. No serious complications were noted in both study groups. CONCLUSIONS: Clinical success rates of PV isolation are similar when using multipolar circular PV ablation catheter and point-by-point ablation with a three-dimensional (3D) navigation system in patients with PAF, and results in shorter procedural and fluoroscopic times with a comparable safety profile.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12026936
003      
CZ-PrNML
005      
20251001140856.0
007      
ta
008      
120816s2010 xxu f 000 0#eng||
009      
AR
024    7_
$a 10.1111/j.1540-8159.2010.02807.x $2 doi
035    __
$a (PubMed)20528997
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Bulava, Alan, $u Heart and Vascular Centre, České Budějovice Hospital, České Budějovice, Czech Republic. alanbulava@seznam.cz $d 1974- $7 xx0106839
245    10
$a Catheter ablation for paroxysmal atrial fibrillation: a randomized comparison between multielectrode catheter and point-by-point ablation / $c A. Bulava, J. Haniš, D. Sitek, O. Ošmera, D. Karpianus, M. Snorek, K. Rehoušková, F. Toušek, L. Pešl,
520    9_
$a INTRODUCTION: Catheter ablation for paroxysmal atrial fibrillation is widely used for patients with drug-refractory paroxysms of arrhythmia. Recently, novel technologies have been introduced to the market that aim to simplify and shorten the procedure. AIM: To compare the clinical outcome of pulmonary vein (PV) isolation using a multipolar circular ablation catheter (PVAC group), with point-by-point PV isolation using an irrigated-tip ablation catheter and the CARTO mapping system (CARTO group; CARTO, Biosense Webster, Diamond Bar, CA, USA). METHODS: Patients with documented PAF were randomized to undergo PV isolation using PVAC or CARTO. Atrial fibrillation (AF) recurrences were documented by serial 7-day Holter monitoring. RESULTS: One hundred and two patients (mean age 58 ± 11 years, 68 men) were included in the study. The patients had comparable baseline clinical characteristics, including left atrial dimensions and left ventricular ejection fraction, in both study arms (PVAC: n = 51 and CARTO: n = 51). Total procedural and fluoroscopic times were significantly shorter in the PVAC group (107 ± 31 minutes vs 208 ± 46 minutes, P < 0.0001 and 16 ± 5 minutes vs 28 ± 8 minutes, P < 0.0001, respectively). The AF recurrence was documented in 23% and 29% of patients in the PVAC and CARTO groups, respectively (P = 0.8), during the mean follow-up of 200 ± 13 days. No serious complications were noted in both study groups. CONCLUSIONS: Clinical success rates of PV isolation are similar when using multipolar circular PV ablation catheter and point-by-point ablation with a three-dimensional (3D) navigation system in patients with PAF, and results in shorter procedural and fluoroscopic times with a comparable safety profile.
650    _2
$a senioři $7 D000368
650    _2
$a fibrilace síní $x radiografie $x chirurgie $7 D001281
650    _2
$a katetrizační ablace $x přístrojové vybavení $x metody $7 D017115
650    _2
$a elektrody $7 D004566
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a fluoroskopie $7 D005471
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a venae pulmonales $x radiografie $x chirurgie $7 D011667
650    _2
$a recidiva $7 D012008
650    _2
$a tepový objem $x fyziologie $7 D013318
650    _2
$a výsledek terapie $7 D016896
651    _2
$a Česká republika $7 D018153
655    _2
$a časopisecké články $7 D016428
655    _2
$a randomizované kontrolované studie $7 D016449
700    1_
$a Haniš, Jiří $7 xx0241224
700    1_
$a Sitek, David $7 xx0248603
700    1_
$a Ošmera, Ondřej $7 xx0336015
700    1_
$a Karpianus, Daniel $7 _AN033248
700    1_
$a Šnorek, Michal $7 xx0241468
700    1_
$a Řehoušková, Kateřina $7 xx0204921
700    1_
$a Toušek, František, $d 1951- $7 xx0105437
700    1_
$a Pešl, Ladislav, $d 1964- $7 xx0103342
773    0_
$w MED00003671 $t Pacing and clinical electrophysiology $x 1540-8159 $g Roč. 33, č. 9 (2010), s. 1039-1046
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20528997 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120816 $b ABA008
991    __
$a 20251001140844 $b ABA008
999    __
$a ok $b bmc $g 948978 $s 784282
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 33 $c 9 $d 1039-1046 $i 1540-8159 $m Pacing and clinical electrophysiology $n Pacing Clin Electrophysiol $x MED00003671
LZP    __
$b NLK113 $a Pubmed-20120816/11/01

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...