-
Je něco špatně v tomto záznamu ?
Production and analytical characterization of neopterin immunoreagents for biosensor developments
I. Cernoch, E. Schleicher, M. Franek
Jazyk angličtina Země Německo
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
NLK
ProQuest Central
od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2011-01-01 do Před 1 rokem
- MeSH
- biosenzitivní techniky metody MeSH
- ELISA metody MeSH
- hapteny chemie imunologie MeSH
- králíci MeSH
- lidé MeSH
- monoklonální protilátky imunologie MeSH
- myši inbrední BALB C MeSH
- myši MeSH
- neopterin krev imunologie MeSH
- protilátky imunologie MeSH
- renální insuficience krev MeSH
- senzitivita a specificita MeSH
- sepse krev MeSH
- specificita protilátek MeSH
- tvorba protilátek MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L(-1), respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L(-1). The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L(-1) could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5-16 μg L(-1) (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12027272
- 003
- CZ-PrNML
- 005
- 20160315163040.0
- 007
- ta
- 008
- 120816s2011 gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-010-4380-6 $2 doi
- 035 __
- $a (PubMed)21088828
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Černoch, Ivo $u Department of Virology and Diagnostics, Veterinary Research Institute, Hudcova 70, 62100, Brno, Czech Republic $7 xx0147219
- 245 10
- $a Production and analytical characterization of neopterin immunoreagents for biosensor developments / $c I. Cernoch, E. Schleicher, M. Franek
- 520 9_
- $a Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L(-1), respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L(-1). The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L(-1) could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5-16 μg L(-1) (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a protilátky $x imunologie $7 D000906
- 650 _2
- $a monoklonální protilátky $x imunologie $7 D000911
- 650 _2
- $a tvorba protilátek $7 D000917
- 650 _2
- $a specificita protilátek $7 D000918
- 650 _2
- $a biosenzitivní techniky $x metody $7 D015374
- 650 _2
- $a ELISA $x metody $7 D004797
- 650 _2
- $a hapteny $x chemie $x imunologie $7 D006241
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a myši $7 D051379
- 650 _2
- $a myši inbrední BALB C $7 D008807
- 650 _2
- $a neopterin $x krev $x imunologie $7 D019798
- 650 _2
- $a králíci $7 D011817
- 650 _2
- $a renální insuficience $x krev $7 D051437
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a sepse $x krev $7 D018805
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Schleicher, Erwin $u Division of Endocrinology, Diabetology, Vascular Medicine, Nephrology and Clinical Chemistry, Department of Internal Medicine, University Hospital Tübingen
- 700 1_
- $a Franek, Milan $u Department of Virology and Diagnostics, Veterinary Research Institute
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 399, č. 2 (2011), s. 979-986
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21088828 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120816 $b ABA008
- 991 __
- $a 20160315162758 $b ABA008
- 999 __
- $a ok $b bmc $g 949314 $s 784618
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 399 $c 2 $d 979-986 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $b NLK112 $a Pubmed-20120816/11/02