Je něco špatně v tomto záznamu ?
Progress in SIFT-MS: breath analysis and other applications
P. Spaněl, D. Smith
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem, přehledy
PubMed
20648679
DOI
10.1002/mas.20303
Knihovny.cz E-zdroje
- MeSH
- dechové testy přístrojové vybavení metody MeSH
- design vybavení MeSH
- hmotnostní spektrometrie přístrojové vybavení metody trendy MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
The development of selected ion flow tube mass spectrometry, SIFT-MS, is described from its inception as the modified very large SIFT instruments used to demonstrate the feasibility of SIFT-MS as an analytical technique, towards the smaller but bulky transportable instruments and finally to the current smallest Profile 3 instruments that have been located in various places, including hospitals and schools to obtain on-line breath analyses. The essential physics and engineering principles are discussed, which must be appreciated to design and construct a SIFT-MS instrument. The versatility and sensitivity of the Profile 3 instrument is illustrated by typical mass spectra obtained using the three precursor ions H(3)O(+), NO(+) and O(2)(+)·, and the need to account for differential ionic diffusion and mass discrimination in the analytical algorithms is emphasized to obtain accurate trace gas analyses. The performance of the Profile 3 instrument is illustrated by the results of several pilot studies, including (i) on-line real time quantification of several breath metabolites for cohorts of healthy adults and children, which have provided representative concentration/population distributions, and the comparative analyses of breath exhaled via the mouth and nose that identify systemic and orally-generated compounds, (ii) the enhancement of breath metabolites by drug ingestion, (iii) the identification of HCN as a marker of Pseudomonas colonization of the airways and (iv) emission of volatile compounds from urine, especially ketone bodies, and from skin. Some very recent developments are discussed, including the quantification of carbon dioxide in breath and the combination of SIFT-MS with GC and ATD, and their significance. Finally, prospects for future SIFT-MS developments are alluded to.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12027393
- 003
- CZ-PrNML
- 005
- 20160226161828.0
- 007
- ta
- 008
- 120816s2010 xxu f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1002/mas.20303 $2 doi
- 035 __
- $a (PubMed)20648679
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Španěl, Patrik $u J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova 3, 182 23, Prague 8, Czech Republic. patrik.spanel@jh-inst.cas.cz $7 xx0118200
- 245 10
- $a Progress in SIFT-MS: breath analysis and other applications / $c P. Spaněl, D. Smith
- 520 9_
- $a The development of selected ion flow tube mass spectrometry, SIFT-MS, is described from its inception as the modified very large SIFT instruments used to demonstrate the feasibility of SIFT-MS as an analytical technique, towards the smaller but bulky transportable instruments and finally to the current smallest Profile 3 instruments that have been located in various places, including hospitals and schools to obtain on-line breath analyses. The essential physics and engineering principles are discussed, which must be appreciated to design and construct a SIFT-MS instrument. The versatility and sensitivity of the Profile 3 instrument is illustrated by typical mass spectra obtained using the three precursor ions H(3)O(+), NO(+) and O(2)(+)·, and the need to account for differential ionic diffusion and mass discrimination in the analytical algorithms is emphasized to obtain accurate trace gas analyses. The performance of the Profile 3 instrument is illustrated by the results of several pilot studies, including (i) on-line real time quantification of several breath metabolites for cohorts of healthy adults and children, which have provided representative concentration/population distributions, and the comparative analyses of breath exhaled via the mouth and nose that identify systemic and orally-generated compounds, (ii) the enhancement of breath metabolites by drug ingestion, (iii) the identification of HCN as a marker of Pseudomonas colonization of the airways and (iv) emission of volatile compounds from urine, especially ketone bodies, and from skin. Some very recent developments are discussed, including the quantification of carbon dioxide in breath and the combination of SIFT-MS with GC and ATD, and their significance. Finally, prospects for future SIFT-MS developments are alluded to.
- 650 _2
- $a dechové testy $x přístrojové vybavení $x metody $7 D001944
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hmotnostní spektrometrie $x přístrojové vybavení $x metody $x trendy $7 D013058
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Smith, David $u Institute for Science and Technology in Medicine, School of Medicine, Keele University, Thornburrow Drive, Hartshill, Stoke-on-Trent ST4 7QB, UK
- 773 0_
- $w MED00003197 $t Mass spectrometry reviews $x 1098-2787 $g Roč. 30, č. 2 (2010), s. 236-267
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20648679 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120816 $b ABA008
- 991 __
- $a 20160226161544 $b ABA008
- 999 __
- $a ok $b bmc $g 949435 $s 784739
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 30 $c 2 $d 236-267 $e 20100720 $i 1098-2787 $m Mass spectrometry reviews $n Mass Spectrom Rev $x MED00003197
- LZP __
- $b NLK112 $a Pubmed-20120816/11/02