Electromembrane extraction of heavy metal cations followed by capillary electrophoresis with capacitively coupled contactless conductivity detection

P. Kubáň, L. Strieglerová, P. Gebauer, P. Boček,

. 2011 ; 32 (9) : 1025-32. [pub] 20110330

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12027671

Electromembrane extraction (EME) was used as an off-line sample pre-treatment method for the determination of heavy metal cations in aqueous samples using CE with capacitively coupled contactless conductivity detection (CE-C(4) D). A short segment of porous polypropylene hollow fibre was penetrated with 1-octanol and 0.5% v/v bis(2-ethylhexyl)phosphonic acid and constituted a low cost, single use, disposable supported liquid membrane, which selectively transported and pre-concentrated heavy metal cations into the fibre lumen filled with 100 mM acetic acid acceptor solution. Donor solutions were standard solutions and real samples dissolved in deionized water at neutral pH. At optimized EME conditions (penetration time, 5 s; applied voltage, 75 V; and stirring rate, 750 rpm), 15-42% recoveries of heavy metal cations were achieved for a 5 min extraction time. Repeatability of the EME pre-treatment was examined for six independent EME runs and ranged from 6.6 to 11.1%. Limits of detection for the EME-CE-C(4) D method ranged from 25 to 200 nM, resulting into one to two orders of magnitude improvement compared with CE-C(4) D without sample treatment. The developed EME sample pre-treatment procedure was applied to the analysis of heavy metal cations in tap water and powdered milk samples. Zinc in the real samples was identified and quantified in a background electrolyte solution consisting of 20 mM L-histidine and 30 mM acetic acid at pH 4.95 in about 3 min.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12027671
003      
CZ-PrNML
005      
20121207100352.0
007      
ta
008      
120817e20110330gw f 000 0#eng||
009      
AR
024    7_
$a 10.1002/elps.201000462 $2 doi
035    __
$a (PubMed)21449072
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Kubáň, Pavel $u Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, Brno, Czech Republic. kuban@iach.cz
245    10
$a Electromembrane extraction of heavy metal cations followed by capillary electrophoresis with capacitively coupled contactless conductivity detection / $c P. Kubáň, L. Strieglerová, P. Gebauer, P. Boček,
520    9_
$a Electromembrane extraction (EME) was used as an off-line sample pre-treatment method for the determination of heavy metal cations in aqueous samples using CE with capacitively coupled contactless conductivity detection (CE-C(4) D). A short segment of porous polypropylene hollow fibre was penetrated with 1-octanol and 0.5% v/v bis(2-ethylhexyl)phosphonic acid and constituted a low cost, single use, disposable supported liquid membrane, which selectively transported and pre-concentrated heavy metal cations into the fibre lumen filled with 100 mM acetic acid acceptor solution. Donor solutions were standard solutions and real samples dissolved in deionized water at neutral pH. At optimized EME conditions (penetration time, 5 s; applied voltage, 75 V; and stirring rate, 750 rpm), 15-42% recoveries of heavy metal cations were achieved for a 5 min extraction time. Repeatability of the EME pre-treatment was examined for six independent EME runs and ranged from 6.6 to 11.1%. Limits of detection for the EME-CE-C(4) D method ranged from 25 to 200 nM, resulting into one to two orders of magnitude improvement compared with CE-C(4) D without sample treatment. The developed EME sample pre-treatment procedure was applied to the analysis of heavy metal cations in tap water and powdered milk samples. Zinc in the real samples was identified and quantified in a background electrolyte solution consisting of 20 mM L-histidine and 30 mM acetic acid at pH 4.95 in about 3 min.
650    _2
$a zvířata $7 D000818
650    _2
$a kationty $x analýza $x izolace a purifikace $7 D002412
650    _2
$a chemická frakcionace $x přístrojové vybavení $x metody $7 D005591
650    _2
$a elektrická vodivost $7 D004553
650    _2
$a elektroforéza kapilární $x metody $7 D019075
650    _2
$a design vybavení $7 D004867
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a těžké kovy $x analýza $x izolace a purifikace $7 D019216
650    _2
$a mléko $x chemie $7 D008892
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a voda $x chemie $7 D014867
650    _2
$a zinek $x analýza $x chemie $x izolace a purifikace $7 D015032
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Strieglerová, Lenka
700    1_
$a Gebauer, Petr
700    1_
$a Boček, Petr
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 32, č. 9 (20110330), s. 1025-32
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21449072 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121207100426 $b ABA008
999    __
$a ok $b bmc $g 949713 $s 785017
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 32 $c 9 $d 1025-32 $e 20110330 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20120817/11/03

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...