1st International comparison measurement on assessing the diffusion coefficient of radon

K. Rovenska, M. Jiránek,

. 2011 ; 145 (2-3) : 127-32. [pub] 20110406

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12028374

Radon diffusion coefficient is a material parameter which is usually used in the radon mitigation measures design. There are different approaches used for radon diffusion coefficient measurement and assessment. The International comparison measurement which was jointly organised by National Radiation Protection Institute and Faculty of Civil Engineering CTU Prague in 2009 and 2010 has registered 11 laboratories from all over the world. Three sets of samples of polyethylene damp-proof membranes were sent to these laboratories for measurement. Till today, the organisers received only five sets of results. The results showed a great variability among laboratories involved.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12028374
003      
CZ-PrNML
005      
20130109010952.0
007      
ta
008      
120817e20110406enk f 000 0#eng||
009      
AR
024    7_
$a 10.1093/rpd/ncr079 $2 doi
035    __
$a (PubMed)21471130
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Navrátilová-Rovenská, Kateřina $7 xx0160326 $u National Radiation Protection Institute, Bartoškova 28, Praha 4, Czech Republic. katerina.rovenska@suro.cz
245    10
$a 1st International comparison measurement on assessing the diffusion coefficient of radon / $c K. Rovenska, M. Jiránek,
520    9_
$a Radon diffusion coefficient is a material parameter which is usually used in the radon mitigation measures design. There are different approaches used for radon diffusion coefficient measurement and assessment. The International comparison measurement which was jointly organised by National Radiation Protection Institute and Faculty of Civil Engineering CTU Prague in 2009 and 2010 has registered 11 laboratories from all over the world. Three sets of samples of polyethylene damp-proof membranes were sent to these laboratories for measurement. Till today, the organisers received only five sets of results. The results showed a great variability among laboratories involved.
650    _2
$a difuze $7 D004058
650    _2
$a vystavení vlivu životního prostředí $x prevence a kontrola $7 D004781
650    _2
$a lidé $7 D006801
650    _2
$a mezinárodní agentury $7 D007390
650    _2
$a monitorování radiace $7 D011834
650    _2
$a radiační ochrana $7 D011835
650    _2
$a radon $x analýza $7 D011886
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Jiránek, Martin, $d 1964- $7 jn20001103389
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 145, č. 2-3 (20110406), s. 127-32
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21471130 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20130109011109 $b ABA008
999    __
$a ok $b bmc $g 950416 $s 785720
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 145 $c 2-3 $d 127-32 $e 20110406 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20120817/11/04

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...