Errors associated with the concentration of epinephrine in endonasal surgery

P. Matoušek, P. Komínek, A. Garčic,

. 2011 ; 268 (7) : 1009-11. [pub] 20110217

Language English Country Germany

Document type Case Reports, Journal Article

This paper presents two cases of using erroneous concentrations of epinephrine during endonasal surgery. The two patients discussed were part of a larger study aimed at monitoring the absorption of epinephrine upon injection into the nasal mucosa. During this study, we observed major cardiovascular reactions in two consecutive patients--ventricular tachycardia with ventricular extrasystole and a significant rise in systolic and diastolic blood pressure and pulse rate. This state required pharmacological intervention. In hindsight, it was found that an erroneous application of ten times higher (1:10,000) concentration of epinephrine than the usual was injected. The applied solution was prepared in our institutional pharmacy and was labelled incorrectly (1:100,000 instead of 1:10,000). The authors have analysed the steps leading to the erroneous applications and recommend safety precautions for the prevention of errors in the concentration levels of epinephrine. Epinephrine injections in concentrations of 1:10,000, followed by analyses of epinephrine levels in venous blood, have not yet been described in available literature.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12028433
003      
CZ-PrNML
005      
20250422081333.0
007      
ta
008      
120817s2011 gw f 000 0#eng||
009      
AR
024    7_
$a 10.1007/s00405-010-1435-4 $2 doi
035    __
$a (PubMed)21328004
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Matoušek, Petr, $d 1973- $u Department of Otolaryngology, University Hospital Ostrava, 17 listopadu Street 1790, 708 52 Ostrava, Czech Republic. petr.matousek@fno.cz $7 xx0068189
245    10
$a Errors associated with the concentration of epinephrine in endonasal surgery / $c P. Matoušek, P. Komínek, A. Garčic,
520    9_
$a This paper presents two cases of using erroneous concentrations of epinephrine during endonasal surgery. The two patients discussed were part of a larger study aimed at monitoring the absorption of epinephrine upon injection into the nasal mucosa. During this study, we observed major cardiovascular reactions in two consecutive patients--ventricular tachycardia with ventricular extrasystole and a significant rise in systolic and diastolic blood pressure and pulse rate. This state required pharmacological intervention. In hindsight, it was found that an erroneous application of ten times higher (1:10,000) concentration of epinephrine than the usual was injected. The applied solution was prepared in our institutional pharmacy and was labelled incorrectly (1:100,000 instead of 1:10,000). The authors have analysed the steps leading to the erroneous applications and recommend safety precautions for the prevention of errors in the concentration levels of epinephrine. Epinephrine injections in concentrations of 1:10,000, followed by analyses of epinephrine levels in venous blood, have not yet been described in available literature.
650    _2
$a dospělí $7 D000328
650    _2
$a anestetika lokální $x aplikace a dávkování $7 D000779
650    _2
$a srdeční arytmie $x chemicky indukované $7 D001145
650    _2
$a vztah mezi dávkou a účinkem léčiva $7 D004305
650    _2
$a adrenalin $x aplikace a dávkování $x škodlivé účinky $7 D004837
650    _2
$a lidé $7 D006801
650    _2
$a injekce $7 D007267
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a medikační omyly $x škodlivé účinky $7 D008508
650    _2
$a lidé středního věku $7 D008875
650    _2
$a nos $x chirurgie $7 D009666
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a trimekain $x aplikace a dávkování $7 D014288
650    _2
$a vazokonstriktory $x aplikace a dávkování $x škodlivé účinky $7 D014662
655    _2
$a kazuistiky $7 D002363
655    _2
$a časopisecké články $7 D016428
700    1_
$a Komínek, Pavel
700    1_
$a Garčic, Antonín
773    0_
$w MED00009617 $t European archives of oto-rhino-laryngology $x 1434-4726 $g Roč. 268, č. 7 (2011), s. 1009-11
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21328004 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120817 $b ABA008
991    __
$a 20250422081335 $b ABA008
999    __
$a ok $b bmc $g 950475 $s 785779
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 268 $c 7 $d 1009-11 $e 20110217 $i 1434-4726 $m European archives of oto-rhino-laryngology $n Eur Arch Otorhinolaryngol $x MED00009617
LZP    __
$a Pubmed-20120817/11/04

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...