Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Vliv uvolnění mediálních stabilizátorů kolena na velikost korekce u vysoké valgizační opening-wedge osteotomie tibie; anatomická studie na kadaverech
[Effect of releasing the medial stabilisers of the knee on the magnitude of correction in opening-wedge high-tibial valgus osteotomy. Anatomy study on cadavers]

F. Okál, R. Hart, M. Komzák

. 2012 ; 79 (4) : 355-360.

Jazyk čeština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc12029623

Digitální knihovna NLK
Zdroj

E-zdroje Online

NLK Free Medical Journals od 2006

PURPOSE OF THE STUDY When a larger opening of high-tibial osteotomy is necessary to achieve good correction of the lower extremity axis, partial release of the attachments of the medial stabilisers of the knee may be required. The aim of the study was to ascertain, in cadaver specimens, the effect of loosening the medial knee stabilisers on the magnitude of correction in medial opening-wedge high-tibial valgus osteotomy. MATERIAL AND METHODS Thirty-eight knees obtained from cadavers of Caucasian race were dissected. Medial opening-wedge high-tibial valgus osteotomy was performed using a dynamic distractor, constructed by us, with a dynamometer to ensure constant force action. Using a kinematic navigation system, the lower leg axis was studied at opening-wedge osteotomy under constant forces of 100 N and 150 N. The change in its angulation was recorded after each step in releasing the medial stabilisers whose structures were gradually made loose, under constant action of the given force, in the following order: superficial portion of the medial collateral ligament, tendons of the gracilis, semitendinosus and sartorius muscles. RESULTS The results were statistically analysed using descriptive statistical methods and the two-sample paired t-test with the level of statistical significance set at p < 0.05. Loosening of the medial stabilisers one by one under a constant load led to a statistically significant change in alignment. The most significant change in angulation, both in clinical and statistical terms, was that of 3.4° occurring after the superficial portion of the medial collateral ligament was made loose under a constant force of 100 N applied to osteotomy. Thus, this loosening contributed by 62% to an overall change of 5.5° in the lower extremity mechanical axis, as compared with the condition not allowing for loosening of the stabilisers. Under a load of 150 N applied to osteotomy, loosening of the medial collateral ligament resulted in a change by 4.1°, which accounted for 56% of an overall change of 7.3° that occurred after all stabilisers were released. On distraction of the osteotomy using a higher force, an increase in a stabilising effect of the pes anserinus was apparent. DISCUSSION The evolution of angle-stable implants has advanced options for reliable fixation of high-tibial corrective osteotomy which involves cutting out a wedge and forcing it open on the medial side. These implants provide stable fixation even when a large correction of the limb mechanical axis is required, and allow for rehabilitation with early weight-bearing. As with a large correction the force needed to make the wedge open is increasing, it is necessary to consider loosening of the medial stabilisers of the knee. According to our knowledge, no study on the effect of individual medial stabilising structures of the knee on the force required to open high-tibial osteotomy with the wedge opened medially has been published. CONCLUSIONS The process of correcting lower extremity alignment by high-tibial opening-wedge valgus osteotomy brings about an increase in tension of the stabilisers on the concave side of the deformity. Our results show an important role of releasing the superficial portion of the medial collateral ligament in the reduction of forces necessary to correct a deformity.

Effect of releasing the medial stabilisers of the knee on the magnitude of correction in opening-wedge high-tibial valgus osteotomy. Anatomy study on cadavers

Obsahuje 2 tabulky

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc12029623
003      
CZ-PrNML
005      
20121025085247.0
007      
ta
008      
120912s2012 xr do f 000 0cze||
009      
AR
024    7_
$2 doi $a 10.55095/achot2012/051
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Okál, František $7 xx0115212 $u Ortopedicko-traumatologické oddělení, Nemocnice Znojmo
245    10
$a Vliv uvolnění mediálních stabilizátorů kolena na velikost korekce u vysoké valgizační opening-wedge osteotomie tibie; anatomická studie na kadaverech / $c F. Okál, R. Hart, M. Komzák
246    31
$a Effect of releasing the medial stabilisers of the knee on the magnitude of correction in opening-wedge high-tibial valgus osteotomy. Anatomy study on cadavers
500    __
$a Obsahuje 2 tabulky
504    __
$a Literatura $b 24
520    9_
$a PURPOSE OF THE STUDY When a larger opening of high-tibial osteotomy is necessary to achieve good correction of the lower extremity axis, partial release of the attachments of the medial stabilisers of the knee may be required. The aim of the study was to ascertain, in cadaver specimens, the effect of loosening the medial knee stabilisers on the magnitude of correction in medial opening-wedge high-tibial valgus osteotomy. MATERIAL AND METHODS Thirty-eight knees obtained from cadavers of Caucasian race were dissected. Medial opening-wedge high-tibial valgus osteotomy was performed using a dynamic distractor, constructed by us, with a dynamometer to ensure constant force action. Using a kinematic navigation system, the lower leg axis was studied at opening-wedge osteotomy under constant forces of 100 N and 150 N. The change in its angulation was recorded after each step in releasing the medial stabilisers whose structures were gradually made loose, under constant action of the given force, in the following order: superficial portion of the medial collateral ligament, tendons of the gracilis, semitendinosus and sartorius muscles. RESULTS The results were statistically analysed using descriptive statistical methods and the two-sample paired t-test with the level of statistical significance set at p < 0.05. Loosening of the medial stabilisers one by one under a constant load led to a statistically significant change in alignment. The most significant change in angulation, both in clinical and statistical terms, was that of 3.4° occurring after the superficial portion of the medial collateral ligament was made loose under a constant force of 100 N applied to osteotomy. Thus, this loosening contributed by 62% to an overall change of 5.5° in the lower extremity mechanical axis, as compared with the condition not allowing for loosening of the stabilisers. Under a load of 150 N applied to osteotomy, loosening of the medial collateral ligament resulted in a change by 4.1°, which accounted for 56% of an overall change of 7.3° that occurred after all stabilisers were released. On distraction of the osteotomy using a higher force, an increase in a stabilising effect of the pes anserinus was apparent. DISCUSSION The evolution of angle-stable implants has advanced options for reliable fixation of high-tibial corrective osteotomy which involves cutting out a wedge and forcing it open on the medial side. These implants provide stable fixation even when a large correction of the limb mechanical axis is required, and allow for rehabilitation with early weight-bearing. As with a large correction the force needed to make the wedge open is increasing, it is necessary to consider loosening of the medial stabilisers of the knee. According to our knowledge, no study on the effect of individual medial stabilising structures of the knee on the force required to open high-tibial osteotomy with the wedge opened medially has been published. CONCLUSIONS The process of correcting lower extremity alignment by high-tibial opening-wedge valgus osteotomy brings about an increase in tension of the stabilisers on the concave side of the deformity. Our results show an important role of releasing the superficial portion of the medial collateral ligament in the reduction of forces necessary to correct a deformity.
650    _2
$a mrtvola $7 D002102
650    _2
$a osteotomie $x metody $7 D010027
650    _2
$a lidé $7 D006801
650    _2
$a lidé středního věku $7 D008875
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a kolenní kloub $x chirurgie $x patofyziologie $7 D007719
650    _2
$a interpretace statistických dat $7 D003627
650    _2
$a nestabilita kloubu $x chirurgie $7 D007593
650    _2
$a ligamentum collaterale tibiale $x chirurgie $7 D017888
650    _2
$a biomechanika $7 D001696
650    _2
$a kloubní ligamenta $x chirurgie $7 D008023
650    _2
$a šlachy $x chirurgie $7 D013710
650    _2
$a tibie $7 D013977
700    1_
$a Hart, Radek, $d 1967- $7 xx0010068 $u Ortopedicko-traumatologické oddělení, Nemocnice Znojmo; Klinika traumatologie, LF MU, Úrazová nemocnice, Brno
700    1_
$a Komzák, Martin. $7 xx0231327 $u Ortopedicko-traumatologické oddělení, Nemocnice Znojmo
773    0_
$t Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca $x 0001-5415 $g Roč. 79, č. 4 (2012), s. 355-360 $w MED00011021
910    __
$a ABA008 $b A 8 $c 507 $y 2
990    __
$a 20120912072544 $b ABA008
991    __
$a 20121025085452 $b ABA008
999    __
$a ok $b bmc $g 951862 $s 787002
BAS    __
$a 3
BMC    __
$a 2012 $b 79 $c 4 $d 355-360 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$c NLK183 $d 20121025 $a 2012-40/ipeh

Citační ukazatele

Nahrávání dat...

Možnosti archivace