Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Comparison of the quality of lower limb magnetic resonance angiographies performed with different paramagnetic contrast agents in relation to body mass index and ejection fraction

L. Hrdina, M. Kocher, M. Herman, M. Cerna, J. Kozak, Z. Tudos, S. Mahathmakanthi, K. Langova

. 2012 ; 156 (2) : 164-170.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články, práce podpořená grantem, srovnávací studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc12039737

AIM: To compare the quality of magnetic resonance angiographies (MRAs) performed with different contrast agents and to evaluate the effect of body mass index (BMI) and ejection fraction (EF) on the quality of these MRAs. MATERIALS AND METHODS: 120 patients between the age of 43 and 86 years were subjected to MRAs with different contrast agents (Gadobutrolum, Dimeglumini gadobenas, Gadofosveset trisodium). Each patient's BMI was calculated, and EF was established using MR examination of the heart. Objective evaluations of the quality of the MRAs were done using abdominal fat-to-aorta enhancement ratio (FAR) comparisons. This ratio was then correlated with the patient's BMI and EF. Subjective evaluations of the quality of the MRAs were done by 5 blinded evaluators. Correlation analysis and analysis of variance were used for statistical assessement. RESULTS: There was no statistically significant difference in FAR for any of the contrast agent groups. There was a mesoscale correlation between a patient's BMI and FAR. However, no correlation was found between the EF and FAR for any of the contrast agent groups. The results of the subjective evaluation showed that there was no statistical difference in the quality of MRAs regardless of the contrast agent used. CONCLUSION: Subjectively there was no statistically significant difference in the quality of the MRAs. Irrespective of the type of contrast used or the patient's EF, the lower the BMI of a patient the higher the signal enhancement and hence the better the quality of the MRA produced in that patient.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12039737
003      
CZ-PrNML
005      
20140324112733.0
007      
ta
008      
121217s2012 xr df f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2011.058 $2 doi
035    __
$a (PubMed)22660207
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Hrdina, Lukáš $7 xx0159588 $u Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic. Lukas.hrdina@post.cz
245    10
$a Comparison of the quality of lower limb magnetic resonance angiographies performed with different paramagnetic contrast agents in relation to body mass index and ejection fraction / $c L. Hrdina, M. Kocher, M. Herman, M. Cerna, J. Kozak, Z. Tudos, S. Mahathmakanthi, K. Langova
520    9
$a AIM: To compare the quality of magnetic resonance angiographies (MRAs) performed with different contrast agents and to evaluate the effect of body mass index (BMI) and ejection fraction (EF) on the quality of these MRAs. MATERIALS AND METHODS: 120 patients between the age of 43 and 86 years were subjected to MRAs with different contrast agents (Gadobutrolum, Dimeglumini gadobenas, Gadofosveset trisodium). Each patient's BMI was calculated, and EF was established using MR examination of the heart. Objective evaluations of the quality of the MRAs were done using abdominal fat-to-aorta enhancement ratio (FAR) comparisons. This ratio was then correlated with the patient's BMI and EF. Subjective evaluations of the quality of the MRAs were done by 5 blinded evaluators. Correlation analysis and analysis of variance were used for statistical assessement. RESULTS: There was no statistically significant difference in FAR for any of the contrast agent groups. There was a mesoscale correlation between a patient's BMI and FAR. However, no correlation was found between the EF and FAR for any of the contrast agent groups. The results of the subjective evaluation showed that there was no statistical difference in the quality of MRAs regardless of the contrast agent used. CONCLUSION: Subjectively there was no statistically significant difference in the quality of the MRAs. Irrespective of the type of contrast used or the patient's EF, the lower the BMI of a patient the higher the signal enhancement and hence the better the quality of the MRA produced in that patient.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a aorta abdominalis $x patologie $7 D001012
650    _2
$a index tělesné hmotnosti $7 D015992
650    _2
$a kontrastní látky $7 D003287
650    _2
$a gadolinium $x diagnostické užití $7 D005682
650    _2
$a srdce $7 D006321
650    _2
$a lidé $7 D006801
650    _2
$a bérec $x krevní zásobení $7 D007866
650    _2
$a magnetická rezonanční angiografie $7 D018810
650    _2
$a magnetická rezonance kinematografická $7 D019028
650    _2
$a meglumin $x analogy a deriváty $x diagnostické užití $7 D008536
650    _2
$a lidé středního věku $7 D008875
650    _2
$a organokovové sloučeniny $x diagnostické užití $7 D009942
650    _2
$a onemocnění periferních arterií $x diagnóza $x patofyziologie $7 D058729
650    _2
$a tepový objem $7 D013318
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Köcher, Martin $7 jn20010309197 $u Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
700    1_
$a Heřman, Miroslav, $d 1959- $7 jn20000400945 $u Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
700    1_
$a Černá, Marie $7 xx0105930 $u Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
700    1_
$a Kozák, Jiří. $7 jo2012739614 $u Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
700    1_
$a Tüdös, Zbyněk $7 xx0128861 $u Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
700    1_
$a Mahathmakanthi, Shankari $u Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
700    1_
$a Langová, Kateřina $7 xx0141371 $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc; Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University Olomouc
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 156, č. 2 (2012), s. 164-170
856    41
$u http://biomed.papers.upol.cz/magno/bio/2012/mn2.php $y domovská stránka časopisu - plný text volně přístupný = fulltext
910    __
$a ABA008 $b A 1502 $c 958 $y 4 $z 0
990    __
$a 20121217 $b ABA008
991    __
$a 20140324112806 $b ABA008
999    __
$a ok $b bmc $g 963289 $s 797325
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 156 $c 2 $d 164-170 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK138 $a Pubmed-20121217

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...