HL7v3 standard was designed to facilitate communication between all types of eHealth applications, regardless of the domain of activity. The exibility of the HL7v3 messages led, however, to proprietary de nitions of HL7v3 messages and structures. In order to unify the communication in di erent domains, pro les have been developed and standardized. In this context, testing plays an important role in assuring interoperability, as well. This paper presents a method to test the interoperability of HL7v3 applications, using the standardized TTCN-3 test scripting language and its corresponding TTCN-3 test system. The full testing process is described, highlighting all the components involved and providing guidelines for implementing them. This approach requires testers to be familiar to the TTCN-3 environment.
Using TTCN-3 for testing the interoperability of HL7v3 based applications [elektronický zdroj] /
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13000311
- 003
- CZ-PrNML
- 005
- 20130308092016.0
- 007
- cr|cn|
- 008
- 130104s2012 xr d fs 000 0eng||
- 009
- eAR
- 024 7_
- $a 10.24105/ejbi.2012.08.4.6 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Egner, Alexandru $u University Politehnica of Bucharest, Romania
- 245 10
- $a Using TTCN-3 for testing the interoperability of HL7v3 based applications $h [elektronický zdroj] / $c Alexandru Egner, Florica Moldoveanu, Nicolae Goga
- 504 __
- $a Literatura $b 10
- 520 9_
- $a HL7v3 standard was designed to facilitate communication between all types of eHealth applications, regardless of the domain of activity. The exibility of the HL7v3 messages led, however, to proprietary de nitions of HL7v3 messages and structures. In order to unify the communication in di erent domains, pro les have been developed and standardized. In this context, testing plays an important role in assuring interoperability, as well. This paper presents a method to test the interoperability of HL7v3 applications, using the standardized TTCN-3 test scripting language and its corresponding TTCN-3 test system. The full testing process is described, highlighting all the components involved and providing guidelines for implementing them. This approach requires testers to be familiar to the TTCN-3 environment.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a lékařská informatika $7 D008490
- 650 12
- $a informační systémy $7 D007256
- 650 _2
- $a referenční standardy $7 D012015
- 700 1_
- $a Moldoveanu, Florica $u University Politehnica of Bucharest, Romania; HL7 Romania Chair
- 700 1_
- $a Goga, Nicolae $u University Politehnica of Bucharest, Romania; University of Groningen, Netherlands
- 773 0_
- $t European journal for biomedical informatics $x 1801-5603 $g Roč. 8, č. 4 (2012), s. 28-32 $w MED00173462
- 856 41
- $u http://www.ejbi.org/img/ejbi/2012/4/Egner_en.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $y 3 $z 0
- 990 __
- $a 20130104083259 $b ABA008
- 991 __
- $a 20130308092652 $b ABA008
- 999 __
- $a ok $b bmc $g 963048 $s 798470
- BAS __
- $a 3 $a 4
- BMC __
- $a 2012 $b 8 $c 4 $d 28-32 $i 1801-5603 $m European Journal for Biomedical Informatics $n Eur. J. Biomed. Inform. (Praha) $x MED00173462
- LZP __
- $c NLK183 $d 20130204 $a NLK 2013-01/vt