Je něco špatně v tomto záznamu ?
If two do the same thing-- comparing IHE Profiles PIX/PDQ based nn HL7 2.x and HL7 version 3
Marek Václavík
Jazyk angličtina Země Česko Médium elektronický zdroj
- MeSH
- informační systémy * MeSH
- lékařská informatika * MeSH
- lidé MeSH
- referenční standardy MeSH
- software MeSH
- Check Tag
- lidé MeSH
Background: IHE integration profiles for managing patient identification, PIX and PDQ, exist in two alternative forms: on the one hand using HL7 2.x, on the other hand based on HL7 Version 3. Objective: Knowing difierences between the competing integration profiles shall assist the user to choose the one better suitable for their specific deployment. Methods: Difierences in the set of interactions, the information model, the vocabulary and the required behavior of individual interactions were analyzed. Results: A list of specific features and constraints for each of the integration profiles was compiled. Conclusions: Not all of the identified deltas originate in the inherent incompatibility between HL7 2.x and 3.0, they also result from the specific constraints imposed by the IHE profile. Identified disparities include the communication pattern, constraints to identifier schemas and pseudonymization capabilities.
If two do the same thing-- comparing IHE Profiles PIX/PDQ based nn HL7 2.x and HL7 version 3 [elektronický zdroj] /
Citace poskytuje Crossref.org
Obsahuje 2 tabulky
Bibliografie atd.Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13000325
- 003
- CZ-PrNML
- 005
- 20130204135830.0
- 007
- cr|cn|
- 008
- 130104s2012 xr fs 000 0eng||
- 009
- eAR
- 024 7_
- $a 10.24105/ejbi.2012.08.4.8 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Václavík, Marek $u SER HealthCare Solutions, Germany
- 245 10
- $a If two do the same thing-- comparing IHE Profiles PIX/PDQ based nn HL7 2.x and HL7 version 3 $h [elektronický zdroj] / $c Marek Václavík
- 500 __
- $a Obsahuje 2 tabulky
- 504 __
- $a Literatura $b 8
- 520 9_
- $a Background: IHE integration profiles for managing patient identification, PIX and PDQ, exist in two alternative forms: on the one hand using HL7 2.x, on the other hand based on HL7 Version 3. Objective: Knowing difierences between the competing integration profiles shall assist the user to choose the one better suitable for their specific deployment. Methods: Difierences in the set of interactions, the information model, the vocabulary and the required behavior of individual interactions were analyzed. Results: A list of specific features and constraints for each of the integration profiles was compiled. Conclusions: Not all of the identified deltas originate in the inherent incompatibility between HL7 2.x and 3.0, they also result from the specific constraints imposed by the IHE profile. Identified disparities include the communication pattern, constraints to identifier schemas and pseudonymization capabilities.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a lékařská informatika $7 D008490
- 650 _2
- $a referenční standardy $7 D012015
- 650 12
- $a informační systémy $7 D007256
- 650 _2
- $a software $7 D012984
- 773 0_
- $t European journal for biomedical informatics $x 1801-5603 $g Roč. 8, č. 4 (2012), s. 40-43 $w MED00173462
- 856 41
- $u http://www.ejbi.org/img/ejbi/2012/4/Vaclavik_en.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $y 3 $z 0
- 990 __
- $a 20130104083259 $b ABA008
- 991 __
- $a 20130204140002 $b ABA008
- 999 __
- $a ok $b bmc $g 963062 $s 798484
- BAS __
- $a 3 $a 4
- BMC __
- $a 2012 $b 8 $c 4 $d 40-43 $i 1801-5603 $m European Journal for Biomedical Informatics $n Eur. J. Biomed. Inform. (Praha) $x MED00173462
- LZP __
- $c NLK183 $d 20130204 $a NLK 2013-01/vt