Something wrong with this record ?
On-line preconcentration of perfluorooctanoic acid and perfluorooctanesulfonic acid by nonaqueous capillary electrophoresis
R. Knob, V. Maier, J. Petr, V. Ranc, J. Sevčík,
Language English Country Germany
Document type Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't
NLK
Medline Complete (EBSCOhost)
from 2012-10-01 to 1 year ago
Wiley Online Library (archiv)
from 1999-01-01 to 2012-12-31
- MeSH
- Acetonitriles MeSH
- Water Pollutants, Chemical isolation & purification MeSH
- Electrophoresis, Capillary methods MeSH
- Solid Phase Extraction MeSH
- Fluorocarbons isolation & purification MeSH
- Caprylates isolation & purification MeSH
- Alkanesulfonic Acids isolation & purification MeSH
- Limit of Detection MeSH
- Methanol MeSH
- Rivers chemistry MeSH
- Solvents MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Research Support, Non-U.S. Gov't MeSH
Separation of major environmental pollutants as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) by capillary electrophoresis is reported for the first time. It is not possible to resolve the solutes in an aqueous media. However, the use of methanol and acetonitrile as the background electrolyte (BGE) solvents allowed their rapid separation in an uncoated capillary. A major effort was put into BGE optimization in respect to both separation efficiency and detection for further on-line preconcentration. 5 mmol.L⁻¹ naphthalene-1-sulfonic acid and 10 mmol.L⁻¹ triethylamine dissolved in ACN/MeOH (50:50 v/v) provided best separation and detection conditions. Next, the large-volume sample stacking and the field-amplified sample injection were applied and compared. Large-volume sample stacking improved limits of detection (LODs) with regard to the standard injection by 69 times for PFOA and 143 times for PFOS with LODs of 280 and 230 nmol.L⁻¹, respectively. Field-amplified sample injection improved LODs 624 times for PFOAand 806 times for PFOS with LODs 31 and 40 nmol.L⁻¹, respectively. Both preconcentration methods showed repeatabilities of migration times less than 1.2% RSD intraday and 6.6% RSD interday. The method was applied on PFOA and PFOS analysis in a sample of river water treated with solid-phase extraction, which further improved LOD toward 5.6 × 10⁻¹⁰ mol.L⁻¹ for PFOS and 6.4 × 10⁻¹⁰ mol.L⁻¹ for PFOA and allows the method to be used for river water contamination screening or decomposition studies.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13000644
- 003
- CZ-PrNML
- 005
- 20130109115456.0
- 007
- ta
- 008
- 130108s2012 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201100665 $2 doi
- 035 __
- $a (PubMed)22821493
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Knob, Radim $u Department of Analytical Chemistry, Faculty of Science, Palacky University in Olomouc, Olomouc, Czech Republic. rknob@seznam.cz
- 245 10
- $a On-line preconcentration of perfluorooctanoic acid and perfluorooctanesulfonic acid by nonaqueous capillary electrophoresis / $c R. Knob, V. Maier, J. Petr, V. Ranc, J. Sevčík,
- 520 9_
- $a Separation of major environmental pollutants as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) by capillary electrophoresis is reported for the first time. It is not possible to resolve the solutes in an aqueous media. However, the use of methanol and acetonitrile as the background electrolyte (BGE) solvents allowed their rapid separation in an uncoated capillary. A major effort was put into BGE optimization in respect to both separation efficiency and detection for further on-line preconcentration. 5 mmol.L⁻¹ naphthalene-1-sulfonic acid and 10 mmol.L⁻¹ triethylamine dissolved in ACN/MeOH (50:50 v/v) provided best separation and detection conditions. Next, the large-volume sample stacking and the field-amplified sample injection were applied and compared. Large-volume sample stacking improved limits of detection (LODs) with regard to the standard injection by 69 times for PFOA and 143 times for PFOS with LODs of 280 and 230 nmol.L⁻¹, respectively. Field-amplified sample injection improved LODs 624 times for PFOAand 806 times for PFOS with LODs 31 and 40 nmol.L⁻¹, respectively. Both preconcentration methods showed repeatabilities of migration times less than 1.2% RSD intraday and 6.6% RSD interday. The method was applied on PFOA and PFOS analysis in a sample of river water treated with solid-phase extraction, which further improved LOD toward 5.6 × 10⁻¹⁰ mol.L⁻¹ for PFOS and 6.4 × 10⁻¹⁰ mol.L⁻¹ for PFOA and allows the method to be used for river water contamination screening or decomposition studies.
- 650 _2
- $a acetonitrily $7 D000097
- 650 _2
- $a kyseliny alkansulfonové $x izolace a purifikace $7 D017738
- 650 _2
- $a kapryláty $x izolace a purifikace $7 D002210
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a fluorokarbony $x izolace a purifikace $7 D005466
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a methanol $7 D000432
- 650 _2
- $a řeky $x chemie $7 D045483
- 650 _2
- $a extrakce na pevné fázi $7 D052616
- 650 _2
- $a rozpouštědla $7 D012997
- 650 _2
- $a chemické látky znečišťující vodu $x izolace a purifikace $7 D014874
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Maier, Vítězslav
- 700 1_
- $a Petr, Jan
- 700 1_
- $a Ranc, Václav
- 700 1_
- $a Sevčík, Juraj
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 33, č. 14 (2012), s. 2159-66
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22821493 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130108 $b ABA008
- 991 __
- $a 20130109115601 $b ABA008
- 999 __
- $a ok $b bmc $g 963426 $s 798808
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 33 $c 14 $d 2159-66 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20130108