Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods
J. Gallo, V. Havranek, I. Cechova, J. Zapletalova
Language English Country Czech Republic
Document type Journal Article
NLK
Directory of Open Access Journals
from 2001
Free Medical Journals
from 1998
ROAD: Directory of Open Access Scholarly Resources
from 2001
PubMed
17426800
DOI
10.5507/bp.2006.049
Knihovny.cz E-resources
- MeSH
- Equipment Failure Analysis MeSH
- Adult MeSH
- Hip Prosthesis MeSH
- Middle Aged MeSH
- Humans MeSH
- Device Removal MeSH
- Polyethylene MeSH
- Prosthesis Failure MeSH
- Aged MeSH
- In Vitro Techniques MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
Background: Polyethylene wear is considered a most important part of periprosthetic osteolysis development. Thus, its measurement is central to contemporary orthopaedics. AIMS: The aim of this paper was to compare the accuracy of three radiographic techniques for wear measurement. Secondly, the influence of the abduction angle of the cup on measurement accuracy was investigated. METHODS: Wear was measured manually in 80 patients by a single observer according to the Livermore, Charnley, and Dorr description. A multi-component statistical analysis was used to test the hypothesis that the Livermore technique was superior. In vitro data obtained from a Universal-type measuring microscope served as a gold standard. RESULTS: In vitro measurements showed an average linear wear of 0.363 mm per year (0.000-0.939, SD 0.241) with a corresponding volumetric wear rate of 161 mm3 per year (0-467, SD 118.2). The Livermore technique showed the least deviation from the optical reference standard and a superior position from the viewpoint of error analysis but the correlation coefficient was slightly less (r = 0.761) than for the Dorr and Charnley techniques (r = 0.795 and r = 0.778, respectively). In addition, the mean error of the Dorr method differed significantly from zero (p = 0.036). Overall, the Livermore technique was the most accurate method for polyethylene wear measurement regardless of the abduction angle of the cup. CONCLUSIONS: The Livermore technique performed manually was more accurate than the Charnley and Dorr methods. Nevertheless, we consider the Dorr technique an adequate tool for day-to-day wear measurements, mainly due to its simplicity.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13003657
- 003
- CZ-PrNML
- 005
- 20130222120347.0
- 007
- ta
- 008
- 130128s2006 xr fdo f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2006.049 $2 doi
- 035 __
- $a (PubMed)17426800
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Gallo, Jiří $7 xx0019005 $u Department of Orthopaedics, Faculty of Medicine and Dentistry and Teaching Hospital, Palacky University, Olomouc
- 245 10
- $a Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods / $c J. Gallo, V. Havranek, I. Cechova, J. Zapletalova
- 520 9_
- $a Background: Polyethylene wear is considered a most important part of periprosthetic osteolysis development. Thus, its measurement is central to contemporary orthopaedics. AIMS: The aim of this paper was to compare the accuracy of three radiographic techniques for wear measurement. Secondly, the influence of the abduction angle of the cup on measurement accuracy was investigated. METHODS: Wear was measured manually in 80 patients by a single observer according to the Livermore, Charnley, and Dorr description. A multi-component statistical analysis was used to test the hypothesis that the Livermore technique was superior. In vitro data obtained from a Universal-type measuring microscope served as a gold standard. RESULTS: In vitro measurements showed an average linear wear of 0.363 mm per year (0.000-0.939, SD 0.241) with a corresponding volumetric wear rate of 161 mm3 per year (0-467, SD 118.2). The Livermore technique showed the least deviation from the optical reference standard and a superior position from the viewpoint of error analysis but the correlation coefficient was slightly less (r = 0.761) than for the Dorr and Charnley techniques (r = 0.795 and r = 0.778, respectively). In addition, the mean error of the Dorr method differed significantly from zero (p = 0.036). Overall, the Livermore technique was the most accurate method for polyethylene wear measurement regardless of the abduction angle of the cup. CONCLUSIONS: The Livermore technique performed manually was more accurate than the Charnley and Dorr methods. Nevertheless, we consider the Dorr technique an adequate tool for day-to-day wear measurements, mainly due to its simplicity.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a odstranění implantátu $7 D020878
- 650 _2
- $a analýza selhání vybavení $7 D019544
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a kyčelní protézy $7 D006622
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a polyethylen $7 D020959
- 650 _2
- $a selhání protézy $7 D011475
- 650 _2
- $a techniky in vitro $7 D066298
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Havránek, Vítězslav. $7 _AN047673 $u Joint Laboratory of Optics, Palacky University Faculty of Science & Academy of Sciences of the Czech Republic, Olomouc
- 700 1_
- $a Čechová, Ivana $7 xx0093685 $u Department of Orthopaedics, Faculty of Medicine and Dentistry and Teaching Hospital, Palacky University, Olomouc
- 700 1_
- $a Zapletalová, Jana $7 xx0111614 $u Department of Biophysics, Palacky University Faculty of Medicine and Dentistry, Olomouc
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 150, č. 2 (2006), s. 321-326
- 910 __
- $a ABA008 $b A 1502 $c sign $y 3 $z 0
- 990 __
- $a 20130128 $b ABA008
- 991 __
- $a 20130222120541 $b ABA008
- 999 __
- $a ok $b bmc $g 966313 $s 801852
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2006 $b 150 $c 2 $d 321-326 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK111 $a Pubmed-20130128