Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Results of selfmonitoring on glucometer systems Advance and Optium in daily routine

R. Chlup, M. Payne, J. Zapletalová, S. Komenda, B. Doubravová, M. Reznícková, L. Chlupová, P. Seckar

. 2005 ; 149 (1) : 127-139.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13003783

Grantová podpora
NR7825 MZ0 CEP - Centrální evidence projektů

The aim of this prospective clinical study was to compare the results of B-glucose estimations performed simultaneously on glucometer Advance (with Micro-draw strips) and Optium (G3 strips) by lay healthy volunteers under non-standardized conditions of everyday life, to assess the difficulties dealing with lay-handling of these systems and to demonstrate the possibilities of the software Glucobalance (Hypoguard) and PC-Link (Medisense/Abbott) for the analysis of selfmonitoring. In the course of 5 days, a total of 721 pairs of measurements were carried out on 10 pairs of glucometer Advance and Optium by 10 healthy volunteers aged 16-40 years. The data transfer of all values into computer from glucometer Advance using the Glucobalance software and from glucometer Optium using the PC-Link was carried out to determine the results. The correlation of B-glucose measured on the glucometer Advance and Optium was strong (r = 0.73). Glucometer Advance brings values about 0.21 +/- 0.06 mmol/l lower than glucometer Optium. The average difference found within each pairs of glucometers Advance - Optium varied. Nevertheless, these differences are acceptable for routine selfmonitoring. The handling of glucometer Advance is not difficult for lay persons. The Glucobalance software simplifies the result evaluation by each tested person. Even though there are some advantages in comparison with the PC-Link, it should be further developed.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13003783
003      
CZ-PrNML
005      
20240731094134.0
007      
ta
008      
130128s2005 xr d f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2005.015 $2 doi
035    __
$a (PubMed)16170399
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Chlup, Rudolf, $d 1947- $7 jn20001031001 $u Institute of Physiology, Faculty of Medicine, Palacký University, Olomouc; IInd Dept. of Medicine, Faculty of Medicine, Palacky University & Teaching Hospital, Olomouc
245    10
$a Results of selfmonitoring on glucometer systems Advance and Optium in daily routine / $c R. Chlup, M. Payne, J. Zapletalová, S. Komenda, B. Doubravová, M. Reznícková, L. Chlupová, P. Seckar
520    9_
$a The aim of this prospective clinical study was to compare the results of B-glucose estimations performed simultaneously on glucometer Advance (with Micro-draw strips) and Optium (G3 strips) by lay healthy volunteers under non-standardized conditions of everyday life, to assess the difficulties dealing with lay-handling of these systems and to demonstrate the possibilities of the software Glucobalance (Hypoguard) and PC-Link (Medisense/Abbott) for the analysis of selfmonitoring. In the course of 5 days, a total of 721 pairs of measurements were carried out on 10 pairs of glucometer Advance and Optium by 10 healthy volunteers aged 16-40 years. The data transfer of all values into computer from glucometer Advance using the Glucobalance software and from glucometer Optium using the PC-Link was carried out to determine the results. The correlation of B-glucose measured on the glucometer Advance and Optium was strong (r = 0.73). Glucometer Advance brings values about 0.21 +/- 0.06 mmol/l lower than glucometer Optium. The average difference found within each pairs of glucometers Advance - Optium varied. Nevertheless, these differences are acceptable for routine selfmonitoring. The handling of glucometer Advance is not difficult for lay persons. The Glucobalance software simplifies the result evaluation by each tested person. Even though there are some advantages in comparison with the PC-Link, it should be further developed.
650    _2
$a mladiství $7 D000293
650    _2
$a dospělí $7 D000328
650    _2
$a krevní glukóza $x analýza $7 D001786
650    _2
$a selfmonitoring glykemie $x přístrojové vybavení $7 D015190
650    _2
$a lidé $7 D006801
650    _2
$a reagenční papírky $7 D011934
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Payne, Martin $u Hypoguard Limited, Woodbridge, United Kingdom
700    1_
$a Zapletalová, Jana $7 xx0111614 $u Department of Biometrics, Faculty of Medicine, Palacky University, Olomouc
700    1_
$a Komenda, Stanislav, $d 1936-2009 $7 jk01061443 $u Department of Biometrics, Faculty of Medicine, Palacky University, Olomouc
700    1_
$a Doubravová, Blanka $7 xx0320541 $u Institute of Neurology and Geriatrics, Moravsky Beroun
700    1_
$a Řezníčková, Martina $7 xx0201141 $u Institute of Physiology, Faculty of Medicine, Palacký University, Olomouc
700    1_
$a Chlupová, Ludmila $7 _AN035019 $u Department of Special Education, Pedagogical Faculty, Palacky University, Olomouc
700    1_
$a Sečkař, Pavel $7 xx0129512 $u Department of Health Insurance, Teaching Hospital Olomouc
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $x 1213-8118 $g Roč. 149, č. 1 (2005), s. 127-139
910    __
$a ABA008 $b A 1502 $c sign $y 3 $z 0
990    __
$a 20130128 $b ABA008
991    __
$a 20240731094132 $b ABA008
999    __
$a ok $b bmc $g 966437 $s 801978
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2005 $b 149 $c 1 $d 127-139 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
GRA    __
$a NR7825 $p MZ0
LZP    __
$b NLK111 $a Pubmed-20130128

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...