Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry
L. Nováková, T. Gottvald, H. Vlčková, F. Trejtnar, J. Mandíková, P. Solich,
Language English Country Netherlands
Document type Journal Article
- MeSH
- Solid Phase Extraction MeSH
- Guanine analogs & derivatives pharmacokinetics urine MeSH
- Hydrophobic and Hydrophilic Interactions MeSH
- Rats MeSH
- Limit of Detection MeSH
- Linear Models MeSH
- Reproducibility of Results MeSH
- Tandem Mass Spectrometry methods MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Animals MeSH
- Check Tag
- Rats MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
Entecavir is a deoxyguanosine nucleotide antiviral agent with the activity against hepatitis B virus (HBV). The agent possesses a polar structure, which is predetermined for hydrophilic interaction chromatography (HILIC). Novel, fast and sensitive HILIC-UHPLC method developed in this study included separation from matrix component on BEH Amide stationary phase by isocratic elution using binary mobile phase composed of acetonitrile/5mM ammonium acetate pH 4.0 (75:25) at flow-rate 0.3 ml/min. Analysis under RP-UHPLC conditions was also possible on BEH C18 stationary phase with mostly aqueous binary mobile phase composed of (4:96) acetonitrile/0.01% formic acid. The comparison of sensitivity of the two UHPLC-MS/MS methods both using selected reaction monitoring (SRM) for quantitation revealed only slightly higher sensitivity for HILIC determination, however much better method linearity, repeatability and accuracy. HILIC separation mode provided also more convenient conditions for straightforward coupling with solid phase extraction (SPE). Entecavir was extracted on Oasis HLB cartridge (1 ml, 30 mg) and eluted by 75% acetonitrile in water, which is actually the HILIC mobile phase used in this study. Therefore the evaporation/reconstitution step was omitted, which substantially accelerated the sample preparation step. The method was validated using stable isotopically labeled internal standard entecavir-C(2)(13) N(15), which is the most appropriate internal standard. Validation results demonstrated good method accuracy (with < 5% error, and 26% at LOQ), recovery (87-114%), precision (<4% RSD), selectivity and sensitivity (LOQ=100 pg/ml). The matrix effects determined by both post-column infusion method as well as post-extraction addition method were negligible (<15%).
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13012708
- 003
- CZ-PrNML
- 005
- 20130411112139.0
- 007
- ta
- 008
- 130404s2012 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2012.03.078 $2 doi
- 035 __
- $a (PubMed)22520634
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Nováková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. nol@email.cz
- 245 10
- $a Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry / $c L. Nováková, T. Gottvald, H. Vlčková, F. Trejtnar, J. Mandíková, P. Solich,
- 520 9_
- $a Entecavir is a deoxyguanosine nucleotide antiviral agent with the activity against hepatitis B virus (HBV). The agent possesses a polar structure, which is predetermined for hydrophilic interaction chromatography (HILIC). Novel, fast and sensitive HILIC-UHPLC method developed in this study included separation from matrix component on BEH Amide stationary phase by isocratic elution using binary mobile phase composed of acetonitrile/5mM ammonium acetate pH 4.0 (75:25) at flow-rate 0.3 ml/min. Analysis under RP-UHPLC conditions was also possible on BEH C18 stationary phase with mostly aqueous binary mobile phase composed of (4:96) acetonitrile/0.01% formic acid. The comparison of sensitivity of the two UHPLC-MS/MS methods both using selected reaction monitoring (SRM) for quantitation revealed only slightly higher sensitivity for HILIC determination, however much better method linearity, repeatability and accuracy. HILIC separation mode provided also more convenient conditions for straightforward coupling with solid phase extraction (SPE). Entecavir was extracted on Oasis HLB cartridge (1 ml, 30 mg) and eluted by 75% acetonitrile in water, which is actually the HILIC mobile phase used in this study. Therefore the evaporation/reconstitution step was omitted, which substantially accelerated the sample preparation step. The method was validated using stable isotopically labeled internal standard entecavir-C(2)(13) N(15), which is the most appropriate internal standard. Validation results demonstrated good method accuracy (with < 5% error, and 26% at LOQ), recovery (87-114%), precision (<4% RSD), selectivity and sensitivity (LOQ=100 pg/ml). The matrix effects determined by both post-column infusion method as well as post-extraction addition method were negligible (<15%).
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a guanin $x analogy a deriváty $x farmakokinetika $x moč $7 D006147
- 650 _2
- $a hydrofobní a hydrofilní interakce $7 D057927
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a lineární modely $7 D016014
- 650 _2
- $a krysa rodu Rattus $7 D051381
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a extrakce na pevné fázi $7 D052616
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Gottvald, Tomáš $u -
- 700 1_
- $a Vlčková, Hana $u -
- 700 1_
- $a Trejtnar, František $u -
- 700 1_
- $a Mandíková, Jana $u -
- 700 1_
- $a Solich, Petr $u -
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1259(2012), s. 237-43
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22520634 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130404 $b ABA008
- 991 __
- $a 20130411112410 $b ABA008
- 999 __
- $a ok $b bmc $g 975906 $s 810989
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 1259 $d 237-43 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20130404