OBJECTIVE: Age-at-death estimation is usually done manually by experts. As such, manual estimation is subjective and greatly depends on the past experience and proficiency of the expert. This becomes even more critical if experts need to evaluate individuals with unknown population affinity or with affinity that they are not familiar with. The purpose of this study is to design a novel age-at-death estimation method allowing for automatic evaluation on computers, thus eliminating the human factor. METHODS: We used a traditional machine-learning approach with explicit feature extraction. First, we identified and described the features that are relevant for age-at-death estimation. Then, we created a multi-linear regression model combining these features. Finally, we analysed the model performance in terms of Mean Absolute Error (MAE), Mean Bias Error (MBE), Slope of Residuals (SoR) and Root Mean Squared Error (RMSE). RESULTS: The main result of this study is a population-independent method of estimating an individual's age-at-death using the acetabulum of the pelvis. Apart from data acquisition, the whole procedure of pre-processing, feature extraction and age estimation is fully automated and implemented as a computer program. This program is a part of a freely available web-based software tool called CoxAGE3D, which is available at https://coxage3d.fit.cvut.cz/. Based on our dataset, the MAE of the presented method is about 10.7 years. In addition, five population-specific models for Thai, Lithuanian, Portuguese, Greek and Swiss populations are also given. The MAEs for these populations are 9.6, 9.8, 10.8, 10.5 and 9.2 years, respectively. Our age-at-death estimation method is suitable for individuals with unknown population affinity and provides acceptable accuracy. The age estimation error cannot be completely eliminated, because it is a consequence of the variability of the ageing process of different individuals not only across different populations but also within a certain population.
- MeSH
- acetabulum * diagnostické zobrazování MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- lineární modely MeSH
- mladý dospělý MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- software * MeSH
- soudní antropologie * metody MeSH
- strojové učení * MeSH
- určení kostního věku * metody MeSH
- zobrazování trojrozměrné * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
The aim of this study was to develop and validate methods for the determination of vitamins B2, B9, E and A in serum using liquid chromatography with mass spectrometry (MS) detection. Vitamin analysis was performed using an ultra performance liquid chromatography combined with tandem MS. The compounds were separated on a BEH C18 RP column (2.1 × 100 mm, 1.7 μm) using a gradient elution with an analysis time of 10 min. Sample preparation included protein precipitation with ethanol. The concentration range in human serum was as follows: riboflavin 5-1000 nmol/L, folic acid 2.5-250 nmol/L, α-tocopherol 0.5-100 μmol/L and all-trans-retinol 25-2500 nmol/L. Accuracy and precision were validated according to Food and Drug Administration guidelines, with coefficients of variation ranging from 3.1-11.7% and recoveries from 94.4-107.5%. Routine monitoring of the complex range of vitamins in bariatric medicine is still not common. This is despite the fact that patients are at risk for glitch deficits, especially of a neurological nature. An analytical method that allows for the complex measurement of both water-soluble and fat-soluble vitamins is important and necessary for the clinical monitoring of bariatric patients. The method we have described could benefit both clinical practice and nutritional research.
- MeSH
- alfa-tokoferol * krev MeSH
- bariatrická chirurgie MeSH
- chromatografie kapalinová metody MeSH
- kyselina listová * krev MeSH
- lidé MeSH
- limita detekce MeSH
- lineární modely MeSH
- reprodukovatelnost výsledků MeSH
- riboflavin * krev MeSH
- tandemová hmotnostní spektrometrie * metody MeSH
- vitamin A * krev MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Fingolimod is an oral drug for the escalation of treatment of relapsing-remitting multiple sclerosis in patients with persistent disease activity on first-line drugs or in patients with rapidly progressive severe relapsing-remitting multiple sclerosis. An ultra-high-performance liquid chromatography-tandem mass spectrometry method for determining the concentrations of fingolimod and its active metabolite fingolimod phosphate in whole blood has been developed and validated. The advantages of this method are the easy, fast and cheap sample preparation using protein precipitation from blood with a mixture of acetonitrile-methanol (40:60, v/v). Chromatographic separation was performed on a ultra-high performance liquid chromatography BEH C18 1.7 μm (100 × 2.1 mm) column. Two modes of ionization, electrospray ionization and atmospheric pressure chemical ionization, were tested and compared. For validation, the electrospray ionization mode was chosen. As internal standard, isotopically labeled fingolimod-D4 was used to quantify the analytes. The method was validated according to the rules of the European Medicines Agency. The coefficients of variation for fingolimod were in the range of 1.13-11.88%, and the recovery was 98.80-106.00%. The coefficients of variation for fingolimod phosphate were in the range of 2.73-9.31%, and the recovery was 90.08-107.00%. The method is quite easy and fast and can be used for routine analysis.
- MeSH
- chromatografie kapalinová metody MeSH
- dospělí MeSH
- fingolimod hydrochlorid * krev farmakokinetika terapeutické užití chemie MeSH
- imunosupresiva krev farmakokinetika MeSH
- lidé MeSH
- limita detekce MeSH
- lineární modely MeSH
- reprodukovatelnost výsledků MeSH
- roztroušená skleróza krev farmakoterapie MeSH
- tandemová hmotnostní spektrometrie * metody MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Foot morphology is associated with altered loading of the ankle-foot complex in adolescent footballers, predisposing to pain and injury. However, usual singular plane clinical assessments do not accurately capture the 3D nature of foot morphology. A new approach is 3D laser scanning, with statistical shape model techniques creating individual-to-group comparison. However, no research exists on the adolescent, football-playing foot. Furthermore, a link between 3D foot morphology, and usual clinical and performance measures would be beneficial for practical implementation. METHODS: Four hundred forty-seven 3D foot scans from 224 elite male footballers (U12-U19) in bilateral stance were collected and further processed with statistical shape model techniques. Weighted shape parameters for individual principal components (Modes) were extracted for each foot. Centre of pressure displacement expressed as total travelled way in millimetres was calculated for bilateral and unilateral postural stability measures. Clinical assessments (Clarke's Angle, Resting Calcaneal Stance Position) were calculated on the 3D foot scans. Differences in weighted shape parameters, postural stability measures, and clinical assessments between age groups were determined by ANOVA. Correlations determined the relationship of Modes and clinical assessments to postural stability measures. Linear regression established if clinical assessments predicted the mode describing foot arch variation. RESULTS: Age groups significantly differed for Mode 1 (foot length), Mode 2 (foot arch), and Mode 5 (tibial rotation relative to the foot) (p < 0.05). Resting Calcaneal Stance Position (r = .663) and Clarke's Angle (r = -.445) were low-to-moderately correlated to Mode 2 (both p < 0.001), and linear regression found they were both significant predictors of Mode 2, though only moderately (R2 = .522). There were low correlations of foot morphology to the postural stability tests. CONCLUSION: This is the first study to describe the 3D foot morphology of male football-playing adolescents, and discover the differences between age groups. This will improve understanding and assessment of foot morphology in male adolescents because 2D techniques, as discovered in this study, do not strongly correlate to, nor predict, the 3D foot arch. Foot morphology was only lowly correlated to postural stability, thus a multifaceted program would be required for improvements.
- MeSH
- dolní končetina * MeSH
- hlezenní kloub MeSH
- lidé MeSH
- lineární modely MeSH
- mladiství MeSH
- patní kost * MeSH
- tibie MeSH
- Check Tag
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Synthetic food colorants are extensively used across the globe regardless of the fact that they induce deleterious side effects when used in higher amounts. In this work, a novel electrochemical sensor based on nickel nanoparticles doped lettuce-like Co3O4 anchored graphene oxide (GO) nanosheets was developed for effective detection of sulfonated azo dye sunset yellow widely used as a food colorant. Hydrothermal synthesis was adopted for the preparation of lettuce-like spinel Co3O4 nanoparticles and Ni-Co3O4 NPs/GO nanocomposite was prepared using ecofriendly and economical sonochemical method. The prepared ternary nanocomposite meticulously fabricated on a screen-printed carbon electrode exhibited remarkable electrocatalytic activity towards sunset yellow determination. This is apparent from the resultant well-defined and intense redox peak currents of Ni-Co3O4 NPs/GO nanocomposite modified electrode at very low potentials. The developed sunset yellow sensor exhibited a high sensitivity of 4.16 μA μM-1 cm-2 and a nanomolar detection limit of 0.9 nM in the linear range 0.125-108.5 μM. Furthermore, experiments were conducted to affirm excellent stability, reproducibility, repeatability, and selectivity of proposed sensor. The practicality of sunset yellow determination using the developed sensor was analyzed in different varieties of food samples including jelly, soft drink, ice cream, and candy resulting in recovery in the range of 96.16%-102.56%.
- MeSH
- azosloučeniny analýza MeSH
- elektrochemické techniky metody MeSH
- grafit MeSH
- kobalt chemie MeSH
- kovové nanočástice chemie MeSH
- limita detekce MeSH
- lineární modely MeSH
- nanokompozity chemie MeSH
- nikl chemie MeSH
- oxid hlinitý chemie MeSH
- oxid hořečnatý chemie MeSH
- oxidy chemie MeSH
- potravinářská barviva analýza MeSH
- reprodukovatelnost výsledků MeSH
- Publikační typ
- časopisecké články MeSH
Permutation methods are commonly used to test the significance of regressors of interest in general linear models (GLMs) for functional (image) data sets, in particular for neuroimaging applications as they rely on mild assumptions. Permutation inference for GLMs typically consists of three parts: choosing a relevant test statistic, computing pointwise permutation tests, and applying a multiple testing correction. We propose new multiple testing methods as an alternative to the commonly used maximum value of test statistics across the image. The new methods improve power and robustness against inhomogeneity of the test statistic across its domain. The methods rely on sorting the permuted functional test statistics based on pointwise rank measures; still, they can be implemented even for large data. The performance of the methods is demonstrated through a designed simulation experiment and an example of brain imaging data. We developed the R package GET, which can be used for the computation of the proposed procedures.
- MeSH
- lidé MeSH
- lineární modely MeSH
- mozek * diagnostické zobrazování MeSH
- neurozobrazování * MeSH
- počítačová simulace MeSH
- výzkumný projekt MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
In comparison with analytical tools, bioassays provide higher sensitivity and more complex evaluation of environmental samples and are indispensable tools for monitoring increasing in anthropogenic pollution. Nevertheless, the disadvantage in cellular assays stems from the material variability used within the assays, and an interlaboratory adaptation does not usually lead to satisfactory test sensitivities. The aim of this study was to evaluate the influence of material variability on CXCL12 secretion by T47D cells, the outcome of the CXCL-test (estrogenic activity assay). For this purpose, the cell line sources, sera suppliers, experimental and seeding media, and the amount of cell/well were tested. The multivariable linear model (MLM), employed as an innovative approach in this field for parameter evaluation, identified that all the tested parameters had significant effects. Knowledge of the contributions of each parameter has permitted step-by-step optimization. The most beneficial approach was seeding 20,000 cells/well directly in treatment medium and using DMEM for the treatment. Great differences in both basal and maximal cytokine secretions among the three tested cell lines and different impacts of each serum were also observed. Altogether, both these biologically based and highly variable inputs were additionally assessed by MLM and a subsequent two-step evaluation, which revealed a lower variability and satisfactory reproducibility of the test. This analysis showed that not only parameter and procedure optimization but also the evaluation methodology must be considered from the perspective of interlaboratory method adaptation. This overall methodology could be applied to all bioanalytical methods for fast multiparameter and accurate analysis.
Cystathionine β-synthase (CBS) deficiency has a wide clinical spectrum, ranging from neurodevelopmental problems, lens dislocation and marfanoid features in early childhood to adult onset disease with predominantly thromboembolic complications. We have analysed clinical and laboratory data at the time of diagnosis in 328 patients with CBS deficiency from the E-HOD (European network and registry for Homocystinurias and methylation Defects) registry. We developed comprehensive criteria to classify patients into four groups of pyridoxine responsivity: non-responders (NR), partial, full and extreme responders (PR, FR and ER, respectively). All groups showed overlapping concentrations of plasma total homocysteine while pyridoxine responsiveness inversely correlated with plasma/serum methionine concentrations. The FR and ER groups had a later age of onset and diagnosis and a longer diagnostic delay than NR and PR patients. Lens dislocation was common in all groups except ER but the age of dislocation increased with increasing responsiveness. Developmental delay was commonest in the NR group while no ER patient had cognitive impairment. Thromboembolism was the commonest presenting feature in ER patients, whereas it was least likely at presentation in the NR group. This probably is due to the differences in ages at presentation: all groups had a similar number of thromboembolic events per 1000 patient-years. Clinical severity of CBS deficiency depends on the degree of pyridoxine responsiveness. Therefore, a standardised pyridoxine-responsiveness test in newly diagnosed patients and a critical review of previous assessments is indispensable to ensure adequate therapy and to prevent or reduce long-term complications.
- MeSH
- cystathionin-beta-synthasa nedostatek MeSH
- dítě MeSH
- dospělí MeSH
- fenotyp MeSH
- homocystinurie diagnóza farmakoterapie enzymologie MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- lineární modely MeSH
- methionin krev MeSH
- mladiství MeSH
- mladý dospělý MeSH
- opožděná diagnóza MeSH
- předškolní dítě MeSH
- pyridoxin terapeutické užití MeSH
- registrace MeSH
- senioři MeSH
- stupeň závažnosti nemoci MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH
A tutorial and spreadsheet for the validation and bottom-up uncertainty evaluation of quantifications performed by instrumental methods of analysis based on linear weighted calibrations is presented. The developed tool automatically assesses if calibrator values uncertainty is negligible given instrumental signal precision, assesses signal homoscedasticity by the Levene's test, guides the selection of weighting factors and evaluates the fitness of the regression model to define the calibration curve. The spreadsheet allows the use of the linear weighted regression model without the need for collecting many replicate signals of calibrators and sample by taking previously developed detailed models of signal precision variation in the calibration interval after adjustments to the daily precision conditions. This tool was successfully applied to the determination of the mass concentration of Cd, Pb, As, Hg, Co, V and Ni in a nasal spray by ICP-MS after samples dilution and acidification. The developed uncertainty models were checked through the analysis of nasal sprays after spiking with known analyte concentration levels. The metrological compatibility between estimated and reference analyte levels for 95% or 99% confidence level supports uncertainty model adequacy. The spiked samples were quantified from many replicate signals but uncertainty evaluation from duplicate calibrator and sample signals was assessed by randomly selecting calibrators and sample signals and by numerically defining a minimum acceptable success rate of the compatibility tests. The developed model was proven adequate to quantify the uncertainty of the studied measurements.
- MeSH
- kalibrace MeSH
- lineární modely MeSH
- nejistota MeSH
- nosní spreje * MeSH
- spektrální analýza MeSH
- Publikační typ
- časopisecké články MeSH
In this study, we describe an inexpensive and rapid method of using video analysis and identity tracking to measure the effects of tag weight on insect movement. In a laboratory experiment, we assessed the tag weight and associated context-dependent effects on movement, choosing temperature as a factor known to affect insect movement and behavior. We recorded the movements of groups of flightless adult crickets Gryllus locorojo (Orthoptera:Gryllidae) as affected by no tag (control); by light, medium, or heavy tags (198.7, 549.2, and 758.6 mg, respectively); and by low, intermediate, or high temperatures (19.5, 24.0, and 28.3°C, respectively). Each individual in each group was weighed before recording and was recorded for 3 consecutive days. The mean (± SD) tag mass expressed as a percentage of body mass before the first recording was 26.8 ± 3.7% with light tags, 72 ± 11.2% with medium tags, and 101.9 ± 13.5% with heavy tags. We found that the influence of tag weight strongly depended on temperature, and that the negative effects on movement generally increased with tag weight. At the low temperature, nearly all movement properties were negatively influenced. At the intermediate and high temperatures, the light and medium tags did not affect any of the movement properties. The continuous 3-day tag load reduced the average movement speed only for crickets with heavy tags. Based on our results, we recommend that researchers consider or investigate the possible effects of tags before conducting any experiment with tags in order to avoid obtaining biased results.