Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry

L. Nováková, T. Gottvald, H. Vlčková, F. Trejtnar, J. Mandíková, P. Solich,

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13012708

Entecavir is a deoxyguanosine nucleotide antiviral agent with the activity against hepatitis B virus (HBV). The agent possesses a polar structure, which is predetermined for hydrophilic interaction chromatography (HILIC). Novel, fast and sensitive HILIC-UHPLC method developed in this study included separation from matrix component on BEH Amide stationary phase by isocratic elution using binary mobile phase composed of acetonitrile/5mM ammonium acetate pH 4.0 (75:25) at flow-rate 0.3 ml/min. Analysis under RP-UHPLC conditions was also possible on BEH C18 stationary phase with mostly aqueous binary mobile phase composed of (4:96) acetonitrile/0.01% formic acid. The comparison of sensitivity of the two UHPLC-MS/MS methods both using selected reaction monitoring (SRM) for quantitation revealed only slightly higher sensitivity for HILIC determination, however much better method linearity, repeatability and accuracy. HILIC separation mode provided also more convenient conditions for straightforward coupling with solid phase extraction (SPE). Entecavir was extracted on Oasis HLB cartridge (1 ml, 30 mg) and eluted by 75% acetonitrile in water, which is actually the HILIC mobile phase used in this study. Therefore the evaporation/reconstitution step was omitted, which substantially accelerated the sample preparation step. The method was validated using stable isotopically labeled internal standard entecavir-C(2)(13) N(15), which is the most appropriate internal standard. Validation results demonstrated good method accuracy (with < 5% error, and 26% at LOQ), recovery (87-114%), precision (<4% RSD), selectivity and sensitivity (LOQ=100 pg/ml). The matrix effects determined by both post-column infusion method as well as post-extraction addition method were negligible (<15%).

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13012708
003      
CZ-PrNML
005      
20130411112139.0
007      
ta
008      
130404s2012 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2012.03.078 $2 doi
035    __
$a (PubMed)22520634
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Nováková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. nol@email.cz
245    10
$a Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry / $c L. Nováková, T. Gottvald, H. Vlčková, F. Trejtnar, J. Mandíková, P. Solich,
520    9_
$a Entecavir is a deoxyguanosine nucleotide antiviral agent with the activity against hepatitis B virus (HBV). The agent possesses a polar structure, which is predetermined for hydrophilic interaction chromatography (HILIC). Novel, fast and sensitive HILIC-UHPLC method developed in this study included separation from matrix component on BEH Amide stationary phase by isocratic elution using binary mobile phase composed of acetonitrile/5mM ammonium acetate pH 4.0 (75:25) at flow-rate 0.3 ml/min. Analysis under RP-UHPLC conditions was also possible on BEH C18 stationary phase with mostly aqueous binary mobile phase composed of (4:96) acetonitrile/0.01% formic acid. The comparison of sensitivity of the two UHPLC-MS/MS methods both using selected reaction monitoring (SRM) for quantitation revealed only slightly higher sensitivity for HILIC determination, however much better method linearity, repeatability and accuracy. HILIC separation mode provided also more convenient conditions for straightforward coupling with solid phase extraction (SPE). Entecavir was extracted on Oasis HLB cartridge (1 ml, 30 mg) and eluted by 75% acetonitrile in water, which is actually the HILIC mobile phase used in this study. Therefore the evaporation/reconstitution step was omitted, which substantially accelerated the sample preparation step. The method was validated using stable isotopically labeled internal standard entecavir-C(2)(13) N(15), which is the most appropriate internal standard. Validation results demonstrated good method accuracy (with < 5% error, and 26% at LOQ), recovery (87-114%), precision (<4% RSD), selectivity and sensitivity (LOQ=100 pg/ml). The matrix effects determined by both post-column infusion method as well as post-extraction addition method were negligible (<15%).
650    _2
$a zvířata $7 D000818
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a guanin $x analogy a deriváty $x farmakokinetika $x moč $7 D006147
650    _2
$a hydrofobní a hydrofilní interakce $7 D057927
650    _2
$a limita detekce $7 D057230
650    _2
$a lineární modely $7 D016014
650    _2
$a krysa rodu Rattus $7 D051381
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a extrakce na pevné fázi $7 D052616
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
655    _2
$a časopisecké články $7 D016428
700    1_
$a Gottvald, Tomáš $u -
700    1_
$a Vlčková, Hana $u -
700    1_
$a Trejtnar, František $u -
700    1_
$a Mandíková, Jana $u -
700    1_
$a Solich, Petr $u -
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1259(2012), s. 237-43
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22520634 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130404 $b ABA008
991    __
$a 20130411112410 $b ABA008
999    __
$a ok $b bmc $g 975906 $s 810989
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 1259 $d 237-43 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20130404

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...