Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Formation of aluminium, aluminium nitride and nitrogen clusters via laser ablation of nano aluminium nitride. Laser Desorption Ionisation and Matrix-Assisted Laser Desorption Ionisation Time-of-Flight Mass Spectrometry

NR. Panyala, V. Prysiazhnyi, P. Slavíček, M. Černák, J. Havel,

. 2011 ; 25 (12) : 1687-93.

Language English Country England, Great Britain

Document type Journal Article

Laser Desorption Ionisation (LDI) and Matrix-Assisted Laser Desorption Ionisation (MALDI) Time-of-Flight Mass Spectrometry (TOFMS) were used to study the pulsed laser ablation of aluminium nitride (AlN) nano powder. The formation of Al(m)(+) (m=1-3), N(n)(+) (n=4, 5), AlN(n)(+) (n=1-5, 19, 21), Al(m)N(+) (m=2-3), Al(3)N(2)(+), Al(9)N(n)(+) (n=5, 7, 9, 11 and 15), Al(11)N(n)(+) (n=4, 6, 10, 12, 19, 21, 23, and 25), and Al(13)N(n)(+) (n=25, 31, 32, 33, 34, 35, and 36) clusters was detected in positive ion mode. Similarly, Al(m)(-) (m=1-3), AlN(n)(-) (n=1-3, 5), Al(m)N(-) (n=2, 3), Al(2)N(n)(-) (n=2-4, 28, 30), N(n)(-) (n=2, 3), Al(4)N(7)(-) Al(8)N(n)(-) (n=1-6), and Al(13)N(n)(-) (n=9, 18, 20, 22, 24, 26, 28, 33, 35, 37, 39, 41 and 43) clusters were observed in negative ion mode. The formation of the stoichiometric Al(10) N(10) cluster was shown to be of low abundance. On the contrary, the laser ablation of nano-AlN led mainly to the formation of nitrogen-rich Al(m)N(n) clusters in both negative and positive ion mode. The stoichiometry of the Al(m)N(n) clusters was determined via isotopic envelope analysis and computer modelling.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13015890
003      
CZ-PrNML
005      
20130509105236.0
007      
ta
008      
130424s2011 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1002/rcm.5030 $2 doi
035    __
$a (PubMed)21598328
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Panyala, Nagender Reddy $u Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5/A14, 625 00 Brno, Czech Republic.
245    10
$a Formation of aluminium, aluminium nitride and nitrogen clusters via laser ablation of nano aluminium nitride. Laser Desorption Ionisation and Matrix-Assisted Laser Desorption Ionisation Time-of-Flight Mass Spectrometry / $c NR. Panyala, V. Prysiazhnyi, P. Slavíček, M. Černák, J. Havel,
520    9_
$a Laser Desorption Ionisation (LDI) and Matrix-Assisted Laser Desorption Ionisation (MALDI) Time-of-Flight Mass Spectrometry (TOFMS) were used to study the pulsed laser ablation of aluminium nitride (AlN) nano powder. The formation of Al(m)(+) (m=1-3), N(n)(+) (n=4, 5), AlN(n)(+) (n=1-5, 19, 21), Al(m)N(+) (m=2-3), Al(3)N(2)(+), Al(9)N(n)(+) (n=5, 7, 9, 11 and 15), Al(11)N(n)(+) (n=4, 6, 10, 12, 19, 21, 23, and 25), and Al(13)N(n)(+) (n=25, 31, 32, 33, 34, 35, and 36) clusters was detected in positive ion mode. Similarly, Al(m)(-) (m=1-3), AlN(n)(-) (n=1-3, 5), Al(m)N(-) (n=2, 3), Al(2)N(n)(-) (n=2-4, 28, 30), N(n)(-) (n=2, 3), Al(4)N(7)(-) Al(8)N(n)(-) (n=1-6), and Al(13)N(n)(-) (n=9, 18, 20, 22, 24, 26, 28, 33, 35, 37, 39, 41 and 43) clusters were observed in negative ion mode. The formation of the stoichiometric Al(10) N(10) cluster was shown to be of low abundance. On the contrary, the laser ablation of nano-AlN led mainly to the formation of nitrogen-rich Al(m)N(n) clusters in both negative and positive ion mode. The stoichiometry of the Al(m)N(n) clusters was determined via isotopic envelope analysis and computer modelling.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Prysiazhnyi, Vadym $u -
700    1_
$a Slavíček, Pavel $u -
700    1_
$a Černák, Mirko $u -
700    1_
$a Havel, Josef $u -
773    0_
$w MED00004050 $t Rapid communications in mass spectrometry : RCM $x 1097-0231 $g Roč. 25, č. 12 (2011), s. 1687-93
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21598328 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130424 $b ABA008
991    __
$a 20130509105541 $b ABA008
999    __
$a ind $b bmc $g 979091 $s 814211
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 25 $c 12 $d 1687-93 $i 1097-0231 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
LZP    __
$a Pubmed-20130424

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...