• Je něco špatně v tomto záznamu ?

Application of wet effluent diffusion denuder for measurement of uptake coefficient of gaseous pollutants

K. Motyka, P. Mikuška, Z. Večeřa,

. 2011 ; 84 (2) : 519-23.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13015950

The comparison of theoretical approaches describing the collection of analyte in the cylindrical wet effluent diffusion denuder (CWEDD) with experimental data is presented. Various absorption liquids were tested for the collection of formaldehyde (distilled-deionized water, H(2)SO(4) solution), acetaldehyde (distilled-deionized water) and nitrous acid (distilled-deionized water, sodium carbonate and sodium bicarbonate solutions of various concentrations and sodium phosphate pH 6-8) in CWEDD. pH of absorption liquids significantly influences the collection of formaldehyde as well as nitrous acid. The collection efficiency of formaldehyde for 0.05 M H(2)SO(4) as absorption liquid was generally higher than for distilled-deionized water. Absorption liquid pH markedly affected the collection efficiency of HONO too (with increasing pH the collection efficiency increase). Data derived by Gormley-Kennedy equation for all investigated compounds were overestimated especially for higher flow rates of air, data calculated with respect to Henry constant are not in good agreement with experimental data and are considerably depended on a determination of the Henry constant value. The CWEDD can be alternative tool for the determination of uptake coefficient. Obtained uptake coefficients were in good agreement with data found in other literature.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13015950
003      
CZ-PrNML
005      
20130424134930.0
007      
ta
008      
130424s2011 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2011.01.032 $2 doi
035    __
$a (PubMed)21376982
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Motyka, Kamil $u Department of Organic Chemistry, Faculty of Science, Institute of Molecular and Translational Medicine, Palacký University, 17. listopadu 12, 771 46 Olomouc, Czech Republic. motyka@orgchem.upol.cz
245    10
$a Application of wet effluent diffusion denuder for measurement of uptake coefficient of gaseous pollutants / $c K. Motyka, P. Mikuška, Z. Večeřa,
520    9_
$a The comparison of theoretical approaches describing the collection of analyte in the cylindrical wet effluent diffusion denuder (CWEDD) with experimental data is presented. Various absorption liquids were tested for the collection of formaldehyde (distilled-deionized water, H(2)SO(4) solution), acetaldehyde (distilled-deionized water) and nitrous acid (distilled-deionized water, sodium carbonate and sodium bicarbonate solutions of various concentrations and sodium phosphate pH 6-8) in CWEDD. pH of absorption liquids significantly influences the collection of formaldehyde as well as nitrous acid. The collection efficiency of formaldehyde for 0.05 M H(2)SO(4) as absorption liquid was generally higher than for distilled-deionized water. Absorption liquid pH markedly affected the collection efficiency of HONO too (with increasing pH the collection efficiency increase). Data derived by Gormley-Kennedy equation for all investigated compounds were overestimated especially for higher flow rates of air, data calculated with respect to Henry constant are not in good agreement with experimental data and are considerably depended on a determination of the Henry constant value. The CWEDD can be alternative tool for the determination of uptake coefficient. Obtained uptake coefficients were in good agreement with data found in other literature.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Mikuška, Pavel $u -
700    1_
$a Večeřa, Zbyněk $u -
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 84, č. 2 (2011), s. 519-23
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21376982 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130424 $b ABA008
991    __
$a 20130424135217 $b ABA008
999    __
$a ind $b bmc $g 979151 $s 814271
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 84 $c 2 $d 519-23 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20130424

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...