Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study

P. Neuzil, VY. Reddy, J. Kautzner, J. Petru, D. Wichterle, D. Shah, H. Lambert, A. Yulzari, E. Wissner, KH. Kuck,

. 2013 ; 6 (2) : 327-33.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu srovnávací studie, časopisecké články, multicentrická studie, randomizované kontrolované studie, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13023934

BACKGROUND: Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up. METHOD AND RESULTS: A radiofrequency ablation catheter with integrated CF sensor (TactiCath, Endosense, Geneva, Switzerland) was used to perform pulmonary vein isolation in 46 patients with paroxysmal atrial fibrillation. During the ablation procedure, the operator was blinded to CF information. At follow-up, an interventional diagnostic procedure was performed to assess gap location as correlated to index procedure ablation parameters. At follow-up, 65% (26/40) of patients showed ≥1 gaps. Ablations with minimum Force-Time Integral (FTI) <400 gs showed increased likelihood for reconnection (P<0.001). Reconnection correlated strongly with minimum CF (P<0.0001) and minimum FTI (P=0.0007) at the site of gap. Gap occurrence showed a strong trend with lower average CF and average FTI. CF and FTI are generally higher on the right side, although the left anterior segment presents a unique challenge to achieve stable position with good CF. CONCLUSIONS: Minimum CF and minimum FTI values are strong predictors of gap formation. Optimal CF parameter recommendations are a target CF of 20 g and a minimum FTI of 400 gs for each new lesion.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13023934
003      
CZ-PrNML
005      
20220526090329.0
007      
ta
008      
130703s2013 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1161/CIRCEP.113.000374 $2 doi
035    __
$a (PubMed)23515263
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Neuzil, Petr $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic. Petr.Neuzil@homolka.cz
245    10
$a Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study / $c P. Neuzil, VY. Reddy, J. Kautzner, J. Petru, D. Wichterle, D. Shah, H. Lambert, A. Yulzari, E. Wissner, KH. Kuck,
520    9_
$a BACKGROUND: Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up. METHOD AND RESULTS: A radiofrequency ablation catheter with integrated CF sensor (TactiCath, Endosense, Geneva, Switzerland) was used to perform pulmonary vein isolation in 46 patients with paroxysmal atrial fibrillation. During the ablation procedure, the operator was blinded to CF information. At follow-up, an interventional diagnostic procedure was performed to assess gap location as correlated to index procedure ablation parameters. At follow-up, 65% (26/40) of patients showed ≥1 gaps. Ablations with minimum Force-Time Integral (FTI) <400 gs showed increased likelihood for reconnection (P<0.001). Reconnection correlated strongly with minimum CF (P<0.0001) and minimum FTI (P=0.0007) at the site of gap. Gap occurrence showed a strong trend with lower average CF and average FTI. CF and FTI are generally higher on the right side, although the left anterior segment presents a unique challenge to achieve stable position with good CF. CONCLUSIONS: Minimum CF and minimum FTI values are strong predictors of gap formation. Optimal CF parameter recommendations are a target CF of 20 g and a minimum FTI of 400 gs for each new lesion.
650    _2
$a mladiství $7 D000293
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a fibrilace síní $x patofyziologie $x chirurgie $7 D001281
650    _2
$a katetrizační ablace $x metody $7 D017115
650    12
$a elektrokardiografie $7 D004562
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a následné studie $7 D005500
650    _2
$a převodní systém srdeční $x patofyziologie $x chirurgie $7 D006329
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a venae pulmonales $x patofyziologie $x chirurgie $7 D011667
650    _2
$a recidiva $7 D012008
650    _2
$a paroxysmální tachykardie $x patofyziologie $x chirurgie $7 D013614
650    _2
$a časové faktory $7 D013997
650    _2
$a výsledek terapie $7 D016896
650    _2
$a mladý dospělý $7 D055815
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a multicentrická studie $7 D016448
655    _2
$a randomizované kontrolované studie $7 D016449
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Reddy, Vivek Y $u -
700    1_
$a Kautzner, Josef $u -
700    1_
$a Petru, Jan $u -
700    1_
$a Wichterle, Dan $u -
700    1_
$a Shah, Dipen $u -
700    1_
$a Lambert, Hendrik $u -
700    1_
$a Yulzari, Aude $u -
700    1_
$a Wissner, Erik $u -
700    1_
$a Kuck, Karl-Heinz, $d 1952- $7 xx0273250
773    0_
$w MED00159578 $t Circulation. Arrhythmia and electrophysiology $x 1941-3084 $g Roč. 6, č. 2 (2013), s. 327-33
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23515263 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130703 $b ABA008
991    __
$a 20220526090323 $b ABA008
999    __
$a ok $b bmc $g 987614 $s 822314
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 6 $c 2 $d 327-33 $i 1941-3084 $m Circulation. Arrhythmia and electrophysiology $n Circ Arrhythm Electrophysiol $x MED00159578
LZP    __
$a Pubmed-20130703

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...