• Je něco špatně v tomto záznamu ?

Multi-element analysis of milk by ICP-oa-TOF-MS after precipitation of calcium and proteins by oxalic and nitric acid

L. Husáková, I. Urbanová, J. Šrámková, M. Konečná, J. Bohuslavová,

. 2013 ; 106 (-) : 66-72.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14040797

In this work a simple technique employing oxalic and nitric acid to cow's milk samples prior to analysis by inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometry (ICP-oa-TOF-MS) was introduced. After the precipitation of calcium and proteins via oxalic and nitric acid, respectively, the resulting liquid phase was aspirated with a concentric glass nebulizer for ICP-TOF-MS determination of trace elements. Precipitation of proteins is essential for better separation of solid and liquid phase of modified samples. Separation of calcium as a precipitated non-soluble oxalate enables the elimination of spectral interferences originating from different calcium containing species like (40)Ca(35)Cl(+), (40)Ca(37)Cl(+), (43)Ca(16)O(+), (40)Ca(18)O(+), (44)Ca(16)O(+), (43)Ca(16)O(1)H(+) onto the determination of As, Se, Co and Ni whose assay is more difficult when using conventional quadrupole instruments. High detection capability is further an advantage as the approach enables the analysis without dilution. The methodology may serve, in addition, for a fast and sensitive determination of some other elements. After that, direct, reliable and simultaneous determination of 16 elements (Li, Be, B, V, Cr, Mn, Ni, Co, Ga, As, Se, Mo, Sn, Sb, Cs, Tl) at trace and ultra-trace levels in milk can be performed under optimum instrumental conditions and by using Rh as an internal standard. Accuracy and precision was assessed by measuring NCS ZC73015 milk powder control standard, yielding results in agreement with certified values and RSD <10%. The accuracy was also checked by comparison of the results of the proposed method with those found by a method based on a microwave-assisted digestion of real samples.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14040797
003      
CZ-PrNML
005      
20140114111812.0
007      
ta
008      
140107s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2012.12.015 $2 doi
035    __
$a (PubMed)23598096
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Husáková, Lenka
245    10
$a Multi-element analysis of milk by ICP-oa-TOF-MS after precipitation of calcium and proteins by oxalic and nitric acid / $c L. Husáková, I. Urbanová, J. Šrámková, M. Konečná, J. Bohuslavová,
520    9_
$a In this work a simple technique employing oxalic and nitric acid to cow's milk samples prior to analysis by inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometry (ICP-oa-TOF-MS) was introduced. After the precipitation of calcium and proteins via oxalic and nitric acid, respectively, the resulting liquid phase was aspirated with a concentric glass nebulizer for ICP-TOF-MS determination of trace elements. Precipitation of proteins is essential for better separation of solid and liquid phase of modified samples. Separation of calcium as a precipitated non-soluble oxalate enables the elimination of spectral interferences originating from different calcium containing species like (40)Ca(35)Cl(+), (40)Ca(37)Cl(+), (43)Ca(16)O(+), (40)Ca(18)O(+), (44)Ca(16)O(+), (43)Ca(16)O(1)H(+) onto the determination of As, Se, Co and Ni whose assay is more difficult when using conventional quadrupole instruments. High detection capability is further an advantage as the approach enables the analysis without dilution. The methodology may serve, in addition, for a fast and sensitive determination of some other elements. After that, direct, reliable and simultaneous determination of 16 elements (Li, Be, B, V, Cr, Mn, Ni, Co, Ga, As, Se, Mo, Sn, Sb, Cs, Tl) at trace and ultra-trace levels in milk can be performed under optimum instrumental conditions and by using Rh as an internal standard. Accuracy and precision was assessed by measuring NCS ZC73015 milk powder control standard, yielding results in agreement with certified values and RSD <10%. The accuracy was also checked by comparison of the results of the proposed method with those found by a method based on a microwave-assisted digestion of real samples.
650    _2
$a zvířata $7 D000818
650    _2
$a vápník $x chemie $7 D002118
650    _2
$a kationty dvojmocné $7 D002413
650    _2
$a chemická precipitace $7 D011232
650    _2
$a mléko $x chemie $7 D008892
650    _2
$a mléčné bílkoviny $x chemie $7 D008894
650    _2
$a kyselina dusičná $x chemie $7 D017942
650    _2
$a kyselina oxalová $x chemie $7 D019815
650    _2
$a referenční standardy $7 D012015
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a spektrometrie hmotnostní - ionizace laserem za účasti matrice $7 D019032
650    _2
$a spektrofotometrie atomová $7 D013054
650    _2
$a stopové prvky $x analýza $7 D014131
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Urbanová, Iva $u -
700    1_
$a Šrámková, Jitka $u -
700    1_
$a Konečná, Michaela $u -
700    1_
$a Bohuslavová, Jana $u -
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 106, č. - (2013), s. 66-72
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23598096 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140107 $b ABA008
991    __
$a 20140114112516 $b ABA008
999    __
$a ok $b bmc $g 1005193 $s 839309
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 106 $c - $d 66-72 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20140107

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...