Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties

D. Šatínský, P. Chocholouš, O. Válová, L. Hanusová, P. Solich,

. 2013 ; 114 (-) : 311-7.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14050845

This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14050845
003      
CZ-PrNML
005      
20140410104243.0
007      
ta
008      
140401s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2013.05.055 $2 doi
035    __
$a (PubMed)23953476
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Šatínský, Dalibor
245    10
$a Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties / $c D. Šatínský, P. Chocholouš, O. Válová, L. Hanusová, P. Solich,
520    9_
$a This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine.
650    _2
$a anestetika lokální $x analýza $x chemie $7 D000779
650    _2
$a antiflogistika $x analýza $x chemie $7 D000893
650    _2
$a chromatografie $x metody $7 D002845
650    _2
$a dexamethason $x analýza $x chemie $7 D003907
650    _2
$a cinchokain $x analýza $x chemie $7 D003992
650    _2
$a lékové roztoky $7 D019999
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Chocholouš, Petr $u -
700    1_
$a Válová, Olga $u -
700    1_
$a Hanusová, Lucia $u -
700    1_
$a Solich, Petr $u -
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 114, č. - (2013), s. 311-7
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23953476 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140401 $b ABA008
991    __
$a 20140410104332 $b ABA008
999    __
$a ok $b bmc $g 1017981 $s 849425
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 114 $c - $d 311-7 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20140401

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...