• Je něco špatně v tomto záznamu ?

Development and validation of an LC-MS/MS method for the determination of six gestagens in kidney fats

M. Rejtharová, L. Rejthar,

. 2013 ; 30 (6) : 995-9.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, validační studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc14051048

A method for the determination of residues of six steroids with gestagenic action (altrenogest, medroxyprogesterone acetate, megestrol acetate, melengestrol acetate, acetoxyprogesterone and chlormadinone acetate) in animal fat tissue was developed. The procedure consists of methanol extraction, clean-up on an alumina column and LC-MS/MS measurement. The method has been validated according to Decision 2002/657/EC. Decision limits for all analytes were observed within the range from 0.3 to 1.7 ng g(-1), and recoveries were between 80% and 105%. The method is robust and can be applied for both screening and confirmatory analyses in routine residue monitoring.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14051048
003      
CZ-PrNML
005      
20140409125259.0
007      
ta
008      
140401s2013 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1080/19440049.2013.789555 $2 doi
035    __
$a (PubMed)23710547
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Rejtharová, Martina
245    10
$a Development and validation of an LC-MS/MS method for the determination of six gestagens in kidney fats / $c M. Rejtharová, L. Rejthar,
520    9_
$a A method for the determination of residues of six steroids with gestagenic action (altrenogest, medroxyprogesterone acetate, megestrol acetate, melengestrol acetate, acetoxyprogesterone and chlormadinone acetate) in animal fat tissue was developed. The procedure consists of methanol extraction, clean-up on an alumina column and LC-MS/MS measurement. The method has been validated according to Decision 2002/657/EC. Decision limits for all analytes were observed within the range from 0.3 to 1.7 ng g(-1), and recoveries were between 80% and 105%. The method is robust and can be applied for both screening and confirmatory analyses in routine residue monitoring.
650    _2
$a tuková tkáň $x chemie $7 D000273
650    _2
$a zvířata $7 D000818
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a ledviny $x chemie $7 D007668
650    _2
$a progestiny $x analýza $7 D011372
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
655    _2
$a časopisecké články $7 D016428
655    _2
$a validační studie $7 D023361
700    1_
$a Rejthar, Libor $u -
773    0_
$w MED00180222 $t Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment $x 1944-0057 $g Roč. 30, č. 6 (2013), s. 995-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23710547 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140401 $b ABA008
991    __
$a 20140409125347 $b ABA008
999    __
$a ok $b bmc $g 1018184 $s 849628
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 30 $c 6 $d 995-9 $i 1944-0057 $m Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment $n Food Addit Contam Part A Chem Anal Control Expo Risk Assess $x MED00180222
LZP    __
$a Pubmed-20140401

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...