• Je něco špatně v tomto záznamu ?

Immunomagnetic molecular probe with UHPLC-MS/MS: a promising way for reliable bronchial asthma diagnostics based on quantification of cysteinyl leukotrienes

K. Syslová, A. Böhmová, E. Demirbağ, K. Šimková, M. Kuzma, D. Pelclová, V. Sedlák, P. Čáp, P. Martásek, P. Kačer,

. 2013 ; 81-82 (-) : 108-117.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu klinické zkoušky kontrolované, časopisecké články, práce podpořená grantem, validační studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc14051096

A sensitive and precise method for simultaneous quantification of cysteinyl leukotrienes (=cys LTs) - leukotriene C4 (=LTC4), leukotriene D4 (=LTD4) and leukotriene E4 (=LTE4) - essential biomarkers of bronchial asthma present in exhaled breath condensate (=EBC) was developed. An immunomagnetic molecular probe was prepared by anchoring cysteinyl leukotrienes antibody on the surface of functionalized monodispersed magnetic particles and used to selectively isolate cys LTs from biological matrices - EBC, plasma and urine. Immobilization and the immunoaffinity capture procedures were optimized to maximize the amount of separated cys LTs, which were detected "off-beads" after acidic elution by UHPLC-ESI-MS/MS operated in a multiple reaction monitoring mode. The developed method was characterized with high precision ≤13.6% (intra-day precision determined as RSD) and ≤14.5% (inter-day precision determined as RSD), acceptable accuracy ≤18.5% (determined as RE), and high recovery of immunoseparation (≥93.1%) in aforementioned biological matrices. The applicability of the method was demonstrated on EBC, plasma and urine clinical samples of patients with various subtypes of bronchial asthma (occupational, steroid-resistant, moderate with and without corticosteroids therapy) and healthy subjects where reasonable differences in cys LTs concentration levels were found. Combining extremely selective immunomagnetic separation with highly sensitive and precise detection step, the developed method was used to aid diagnosis, predict the most effective therapy, and monitor the response to treatment. The detection of elevated inflammatory mediators (cys LTs) in EBC of subjects with relatively asymptomatic asthma and normal pulmonary function tests could offer a novel way for monitoring the lung inflammation and perhaps initiating treatment in an earlier stage.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14051096
003      
CZ-PrNML
005      
20170411121209.0
007      
ta
008      
140401s2013 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jpba.2013.03.026 $2 doi
035    __
$a (PubMed)23644905
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Syslová, Kamila
245    10
$a Immunomagnetic molecular probe with UHPLC-MS/MS: a promising way for reliable bronchial asthma diagnostics based on quantification of cysteinyl leukotrienes / $c K. Syslová, A. Böhmová, E. Demirbağ, K. Šimková, M. Kuzma, D. Pelclová, V. Sedlák, P. Čáp, P. Martásek, P. Kačer,
520    9_
$a A sensitive and precise method for simultaneous quantification of cysteinyl leukotrienes (=cys LTs) - leukotriene C4 (=LTC4), leukotriene D4 (=LTD4) and leukotriene E4 (=LTE4) - essential biomarkers of bronchial asthma present in exhaled breath condensate (=EBC) was developed. An immunomagnetic molecular probe was prepared by anchoring cysteinyl leukotrienes antibody on the surface of functionalized monodispersed magnetic particles and used to selectively isolate cys LTs from biological matrices - EBC, plasma and urine. Immobilization and the immunoaffinity capture procedures were optimized to maximize the amount of separated cys LTs, which were detected "off-beads" after acidic elution by UHPLC-ESI-MS/MS operated in a multiple reaction monitoring mode. The developed method was characterized with high precision ≤13.6% (intra-day precision determined as RSD) and ≤14.5% (inter-day precision determined as RSD), acceptable accuracy ≤18.5% (determined as RE), and high recovery of immunoseparation (≥93.1%) in aforementioned biological matrices. The applicability of the method was demonstrated on EBC, plasma and urine clinical samples of patients with various subtypes of bronchial asthma (occupational, steroid-resistant, moderate with and without corticosteroids therapy) and healthy subjects where reasonable differences in cys LTs concentration levels were found. Combining extremely selective immunomagnetic separation with highly sensitive and precise detection step, the developed method was used to aid diagnosis, predict the most effective therapy, and monitor the response to treatment. The detection of elevated inflammatory mediators (cys LTs) in EBC of subjects with relatively asymptomatic asthma and normal pulmonary function tests could offer a novel way for monitoring the lung inflammation and perhaps initiating treatment in an earlier stage.
650    _2
$a bronchiální astma $x diagnóza $x farmakoterapie $x patofyziologie $7 D001249
650    _2
$a dechové testy $7 D001944
650    _2
$a studie případů a kontrol $7 D016022
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a glukokortikoidy $x terapeutické užití $7 D005938
650    _2
$a lidé $7 D006801
650    _2
$a imunomagnetická separace $x metody $7 D018189
650    _2
$a leukotrien C4 $x analýza $7 D017997
650    _2
$a leukotrien D4 $x analýza $7 D017998
650    _2
$a leukotrien E4 $x analýza $7 D017999
650    _2
$a lidé středního věku $7 D008875
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
655    _2
$a klinické zkoušky kontrolované $7 D018848
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a validační studie $7 D023361
700    1_
$a Böhmová, Adéla $u -
700    1_
$a Demirbağ, Elvan $u -
700    1_
$a Šimková, Kateřina $u -
700    1_
$a Kuzma, Marek $u -
700    1_
$a Pelclová, Daniela $u -
700    1_
$a Sedlák, Vratislav, $u - $d 1975- $7 xx0106182
700    1_
$a Čáp, Petr $u -
700    1_
$a Martásek, Pavel $u -
700    1_
$a Kačer, Petr $u -
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 81-82, č. - (2013), s. 108-117
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23644905 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140401 $b ABA008
991    __
$a 20170411121508 $b ABA008
999    __
$a ok $b bmc $g 1018232 $s 849676
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 81-82 $c - $d 108-117 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
LZP    __
$a Pubmed-20140401

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace