Immunomagnetic molecular probe with UHPLC-MS/MS: a promising way for reliable bronchial asthma diagnostics based on quantification of cysteinyl leukotrienes
K. Syslová, A. Böhmová, E. Demirbağ, K. Šimková, M. Kuzma, D. Pelclová, V. Sedlák, P. Čáp, P. Martásek, P. Kačer,
Language English Country England, Great Britain
Document type Controlled Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't, Validation Study
- MeSH
- Asthma diagnosis drug therapy physiopathology MeSH
- Breath Tests MeSH
- Glucocorticoids therapeutic use MeSH
- Spectrometry, Mass, Electrospray Ionization methods MeSH
- Immunomagnetic Separation methods MeSH
- Leukotriene C4 analysis MeSH
- Leukotriene D4 analysis MeSH
- Leukotriene E4 analysis MeSH
- Middle Aged MeSH
- Humans MeSH
- Reproducibility of Results MeSH
- Sensitivity and Specificity MeSH
- Case-Control Studies MeSH
- Tandem Mass Spectrometry methods MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Publication type
- Journal Article MeSH
- Controlled Clinical Trial MeSH
- Research Support, Non-U.S. Gov't MeSH
- Validation Study MeSH
A sensitive and precise method for simultaneous quantification of cysteinyl leukotrienes (=cys LTs) - leukotriene C4 (=LTC4), leukotriene D4 (=LTD4) and leukotriene E4 (=LTE4) - essential biomarkers of bronchial asthma present in exhaled breath condensate (=EBC) was developed. An immunomagnetic molecular probe was prepared by anchoring cysteinyl leukotrienes antibody on the surface of functionalized monodispersed magnetic particles and used to selectively isolate cys LTs from biological matrices - EBC, plasma and urine. Immobilization and the immunoaffinity capture procedures were optimized to maximize the amount of separated cys LTs, which were detected "off-beads" after acidic elution by UHPLC-ESI-MS/MS operated in a multiple reaction monitoring mode. The developed method was characterized with high precision ≤13.6% (intra-day precision determined as RSD) and ≤14.5% (inter-day precision determined as RSD), acceptable accuracy ≤18.5% (determined as RE), and high recovery of immunoseparation (≥93.1%) in aforementioned biological matrices. The applicability of the method was demonstrated on EBC, plasma and urine clinical samples of patients with various subtypes of bronchial asthma (occupational, steroid-resistant, moderate with and without corticosteroids therapy) and healthy subjects where reasonable differences in cys LTs concentration levels were found. Combining extremely selective immunomagnetic separation with highly sensitive and precise detection step, the developed method was used to aid diagnosis, predict the most effective therapy, and monitor the response to treatment. The detection of elevated inflammatory mediators (cys LTs) in EBC of subjects with relatively asymptomatic asthma and normal pulmonary function tests could offer a novel way for monitoring the lung inflammation and perhaps initiating treatment in an earlier stage.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14051096
- 003
- CZ-PrNML
- 005
- 20170411121209.0
- 007
- ta
- 008
- 140401s2013 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jpba.2013.03.026 $2 doi
- 035 __
- $a (PubMed)23644905
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Syslová, Kamila
- 245 10
- $a Immunomagnetic molecular probe with UHPLC-MS/MS: a promising way for reliable bronchial asthma diagnostics based on quantification of cysteinyl leukotrienes / $c K. Syslová, A. Böhmová, E. Demirbağ, K. Šimková, M. Kuzma, D. Pelclová, V. Sedlák, P. Čáp, P. Martásek, P. Kačer,
- 520 9_
- $a A sensitive and precise method for simultaneous quantification of cysteinyl leukotrienes (=cys LTs) - leukotriene C4 (=LTC4), leukotriene D4 (=LTD4) and leukotriene E4 (=LTE4) - essential biomarkers of bronchial asthma present in exhaled breath condensate (=EBC) was developed. An immunomagnetic molecular probe was prepared by anchoring cysteinyl leukotrienes antibody on the surface of functionalized monodispersed magnetic particles and used to selectively isolate cys LTs from biological matrices - EBC, plasma and urine. Immobilization and the immunoaffinity capture procedures were optimized to maximize the amount of separated cys LTs, which were detected "off-beads" after acidic elution by UHPLC-ESI-MS/MS operated in a multiple reaction monitoring mode. The developed method was characterized with high precision ≤13.6% (intra-day precision determined as RSD) and ≤14.5% (inter-day precision determined as RSD), acceptable accuracy ≤18.5% (determined as RE), and high recovery of immunoseparation (≥93.1%) in aforementioned biological matrices. The applicability of the method was demonstrated on EBC, plasma and urine clinical samples of patients with various subtypes of bronchial asthma (occupational, steroid-resistant, moderate with and without corticosteroids therapy) and healthy subjects where reasonable differences in cys LTs concentration levels were found. Combining extremely selective immunomagnetic separation with highly sensitive and precise detection step, the developed method was used to aid diagnosis, predict the most effective therapy, and monitor the response to treatment. The detection of elevated inflammatory mediators (cys LTs) in EBC of subjects with relatively asymptomatic asthma and normal pulmonary function tests could offer a novel way for monitoring the lung inflammation and perhaps initiating treatment in an earlier stage.
- 650 _2
- $a bronchiální astma $x diagnóza $x farmakoterapie $x patofyziologie $7 D001249
- 650 _2
- $a dechové testy $7 D001944
- 650 _2
- $a studie případů a kontrol $7 D016022
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a glukokortikoidy $x terapeutické užití $7 D005938
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a imunomagnetická separace $x metody $7 D018189
- 650 _2
- $a leukotrien C4 $x analýza $7 D017997
- 650 _2
- $a leukotrien D4 $x analýza $7 D017998
- 650 _2
- $a leukotrien E4 $x analýza $7 D017999
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 655 _2
- $a klinické zkoušky kontrolované $7 D018848
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a validační studie $7 D023361
- 700 1_
- $a Böhmová, Adéla $u -
- 700 1_
- $a Demirbağ, Elvan $u -
- 700 1_
- $a Šimková, Kateřina $u -
- 700 1_
- $a Kuzma, Marek $u -
- 700 1_
- $a Pelclová, Daniela $u -
- 700 1_
- $a Sedlák, Vratislav, $u - $d 1975- $7 xx0106182
- 700 1_
- $a Čáp, Petr $u -
- 700 1_
- $a Martásek, Pavel $u -
- 700 1_
- $a Kačer, Petr $u -
- 773 0_
- $w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 81-82, č. - (2013), s. 108-117
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23644905 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20140401 $b ABA008
- 991 __
- $a 20170411121508 $b ABA008
- 999 __
- $a ok $b bmc $g 1018232 $s 849676
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 81-82 $c - $d 108-117 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
- LZP __
- $a Pubmed-20140401