Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Detection of 2-(dialkylamino)ethanethiols and v-series nerve agents in water and aqueous solutions using folin-ciocalteu reagent

Vladimir Pitschmann, Lukas Matejovsky, Zbynek Kobliha

. 2013 ; 82 (4) : 149-155.

Language English Country Czech Republic

Document type Research Support, Non-U.S. Gov't

A simple colorimetric tube detector for the detection of 2-(dialkylamino)ethanethiols and V-series nerve agents in water and in aqueous solutions is proposed. The detector is based on the reaction of the compounds with a chromogenic Folin-Ciocalteu reagent yielding a blue coloured reduction product. The detection limit of 2-(dialkylamino)ethanethiols is 2.5 mg/l, measurement range up to 250 mg/l. The detection limit of the V (VX) agent is 10 mg/l. The method allows V agents and their precursors and hydrolysis products to be easily distinguished from G-series nerve agents.

References provided by Crossref.org

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc14057769
003      
CZ-PrNML
005      
20140623101713.0
007      
ta
008      
140507s2013 xr d f 000 0eng||
009      
AR
024    7_
$a 10.31482/mmsl.2013.024 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Pitschmann, Vladimír $7 xx0001010 $u Oritest spol. s.r.o., Prague
245    10
$a Detection of 2-(dialkylamino)ethanethiols and v-series nerve agents in water and aqueous solutions using folin-ciocalteu reagent / $c Vladimir Pitschmann, Lukas Matejovsky, Zbynek Kobliha
504    __
$a Literatura
520    9_
$a A simple colorimetric tube detector for the detection of 2-(dialkylamino)ethanethiols and V-series nerve agents in water and in aqueous solutions is proposed. The detector is based on the reaction of the compounds with a chromogenic Folin-Ciocalteu reagent yielding a blue coloured reduction product. The detection limit of 2-(dialkylamino)ethanethiols is 2.5 mg/l, measurement range up to 250 mg/l. The detection limit of the V (VX) agent is 10 mg/l. The method allows V agents and their precursors and hydrolysis products to be easily distinguished from G-series nerve agents.
650    12
$a chemické bojové látky $x izolace a purifikace $x škodlivé účinky $7 D002619
650    12
$a organothiofosforové sloučeniny $x izolace a purifikace $7 D009946
650    12
$a chemické znečištění vody $x analýza $x škodlivé účinky $7 D014877
650    _2
$a kolorimetrie $x metody $x přístrojové vybavení $x využití $7 D003124
650    _2
$a indikátory a reagencie $7 D007202
650    _2
$a statistika jako téma $7 D013223
650    _2
$a lidé $7 D006801
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Matějovský, Lukáš $7 _AN077844 $u Institute of Chemical Technology, Faculty of Environmental Technology, Prague
700    1_
$a Kobliha, Zbyněk $7 _AN043412 $u NBC Defence Institute, University of Defence, Brno
773    0_
$t Vojenské zdravotnické listy $x 0372-7025 $g Roč. 82, č. 4 (2013), s. 149-155 $w MED00011116
856    41
$u http://www.mmsl.cz/archive/2013 $y domovská stránka časopisu - plný text volně přístupný
910    __
$a ABA008 $b A 3 $c 1073 $y 4 $z 0
990    __
$a 20140128155441 $b ABA008
991    __
$a 20140623101943 $b ABA008
999    __
$a ok $b bmc $g 1024621 $s 856376
BAS    __
$a 3
BMC    __
$a 2013 $b 82 $c 4 $d 149-155 $i 0372-7025 $m Vojenské zdravotnické listy $n Vojen. zdr. listy $x MED00011116
LZP    __
$c NLK184 $d 20140623 $a NLK 2014-23/dk

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...