• Je něco špatně v tomto záznamu ?

On-line speciation analysis of inorganic arsenic in complex environmental aqueous samples by pervaporation sequential injection analysis

W. Boonjob, M. Miró, SD. Kolev,

. 2013 ; 117 (-) : 8-13.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14063852

A proof of concept of a novel pervaporation sequential injection (PSI) analysis method for automatic non-chromatographic speciation analysis of inorganic arsenic in complex aqueous samples is presented. The method is based on hydride generation of arsine followed by its on-line pervaporation-based membrane separation and CCD spectrophotometric detection. The concentrations of arsenite (As(III)) and arsenate (As(V)) are determined sequentially in a single sample zone. The leading section of the sample zone merges with a citric acid/citrate buffer solution (pH 4.5) for the selective reduction of As(III) to arsine while the trailing section of the sample zone merges with hydrochloric acid solution to allow the reduction of both As(III) and As(V) to arsine at pH lower than 1. Virtually identical analytical sensitivity is obtained for both As(III) and As(V) at this high acidity. The flow analyzer also accommodates in-line pH detector for monitoring of the acidity throughout the sample zone prior to hydride generation. Under optimal conditions the proposed PSI method is characterized by a limit of detection, linear calibration range and repeatability for As(III) of 22 μg L(-1) (3sblank level criterion), 50-1000 μg L(-1) and 3.0% at the 500 μg L(-1) level and for As(V) of 51 μg L(-1), 100-2000 μg L(-1) and 2.6% at the 500 μg L(-1) level, respectively. The method was validated with mixed As(III)/As(V) standard aqueous solutions and successfully applied to the determination of As(III) and As(V) in river water samples with elevated content of dissolved organic carbon and suspended particulate matter with no prior sample pretreatment. Excellent relative recoveries ranging from 98% to 104% were obtained for both As(III) and As(V).

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14063852
003      
CZ-PrNML
005      
20250114081650.0
007      
ta
008      
140704s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2013.08.032 $2 doi
035    __
$a (PubMed)24209302
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Boonjob, Warunya $u FI-TRACE group, Department of Chemistry, Faculty of Science, University of Balearic Islands, Palma de Mallorca, Spain; Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic; School of Chemistry, The University of Melbourne, Victoria 3010, Australia. $7 xx0327572
245    10
$a On-line speciation analysis of inorganic arsenic in complex environmental aqueous samples by pervaporation sequential injection analysis / $c W. Boonjob, M. Miró, SD. Kolev,
520    9_
$a A proof of concept of a novel pervaporation sequential injection (PSI) analysis method for automatic non-chromatographic speciation analysis of inorganic arsenic in complex aqueous samples is presented. The method is based on hydride generation of arsine followed by its on-line pervaporation-based membrane separation and CCD spectrophotometric detection. The concentrations of arsenite (As(III)) and arsenate (As(V)) are determined sequentially in a single sample zone. The leading section of the sample zone merges with a citric acid/citrate buffer solution (pH 4.5) for the selective reduction of As(III) to arsine while the trailing section of the sample zone merges with hydrochloric acid solution to allow the reduction of both As(III) and As(V) to arsine at pH lower than 1. Virtually identical analytical sensitivity is obtained for both As(III) and As(V) at this high acidity. The flow analyzer also accommodates in-line pH detector for monitoring of the acidity throughout the sample zone prior to hydride generation. Under optimal conditions the proposed PSI method is characterized by a limit of detection, linear calibration range and repeatability for As(III) of 22 μg L(-1) (3sblank level criterion), 50-1000 μg L(-1) and 3.0% at the 500 μg L(-1) level and for As(V) of 51 μg L(-1), 100-2000 μg L(-1) and 2.6% at the 500 μg L(-1) level, respectively. The method was validated with mixed As(III)/As(V) standard aqueous solutions and successfully applied to the determination of As(III) and As(V) in river water samples with elevated content of dissolved organic carbon and suspended particulate matter with no prior sample pretreatment. Excellent relative recoveries ranging from 98% to 104% were obtained for both As(III) and As(V).
650    _2
$a arseničnany $x izolace a purifikace $7 D001149
650    _2
$a arsenikové přípravky $x chemie $7 D001152
650    _2
$a arsenitany $x izolace a purifikace $7 D018053
650    _2
$a kalibrace $7 D002138
650    _2
$a kyselina citronová $x chemie $7 D019343
650    _2
$a průtoková injekční analýza $x metody $7 D017022
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a limita detekce $7 D057230
650    _2
$a řeky $x chemie $7 D045483
650    _2
$a spektrofotometrie $x přístrojové vybavení $x metody $7 D013053
650    _2
$a chemické látky znečišťující vodu $x izolace a purifikace $7 D014874
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Miró, Manuel
700    1_
$a Kolev, Spas D
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 117 (2013), s. 8-13
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24209302 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140704 $b ABA008
991    __
$a 20250114081647 $b ABA008
999    __
$a ok $b bmc $g 1031336 $s 862584
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 117 $c - $d 8-13 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20140704

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...