-
Something wrong with this record ?
A comparison between transcutaneous and total serum bilirubin in healthy-term greek neonates with clinical jaundice
C. Neocleous, A. Adramerina, S. Limnaios, S. Symeonidis, C. Spanou, M. Malakozi, E. Mpampalis
Language English Country Czech Republic
Document type Clinical Trial, Comparative Study, Journal Article
NLK
Directory of Open Access Journals
from 2012
Medline Complete (EBSCOhost)
from 2012-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2013
- MeSH
- Bilirubin analysis metabolism MeSH
- Forehead MeSH
- Humans MeSH
- Infant, Newborn MeSH
- Jaundice, Neonatal diagnosis metabolism MeSH
- Neonatal Screening instrumentation MeSH
- Prospective Studies MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Infant, Newborn MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Clinical Trial MeSH
- Comparative Study MeSH
- Geographicals
- Greece MeSH
The accuracy of transcutaneous bilirubin meters has been assessed in newborns from various ethnic backgrounds. However, there are limited data on Greek newborns. Our study examined the accuracy of transcutaneous bilirubin measurements in clinically jaundiced healthy-term Greek newborns, using total serum bilirubin as the reference standard, in order to re-evaluate our local guidelines about neonatal jaundice. Clinically jaundiced newborns requiring total serum bilirubin level estimation were recruited prospectively. 368 pairs of total serum bilirubin/transcutaneous bilirubin measurements were taken in 222 newborns, using a direct spectrophotometric device and the BiliCheck device, respectively. The level of agreement between the obtained transcutaneous bilirubin and total serum bilirubin values was assessed. Our data were analysed using the Stata/SE 12.0 (StataCorp LP, USA) statistical programme. The mean (± SD) TSB was 225.4 ± 25.4 μmol/l and the mean (± SD) TcB was 237.9 ± 21.0 μmol/l. The correlation between the values was poor (Pearson's correlation coefficient 0.439; Lin's concordance coefficient 0.377 [95% CI 0.301 to 0.453]; P<0.001). The Bland-Altman analysis demonstrated that transcutaneous bilirubin measurements tended to overestimate the total serum bilirubin value (mean difference 12.5 ± 24.9 μmol/l), with wide 95% limits of agreement (-36.2 μmol/l to 61.3 μmol/l). Transcutaneous bilirubin values did not correlate well with total serum bilirubin values, being often imprecise in predicting the actual total serum bilirubin levels. This permits us to continue estimating total serum bilirubin in clinically jaundiced newborns according to our local guidelines, in order to safely decide the appropriate care plan.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14074095
- 003
- CZ-PrNML
- 005
- 20141014073128.0
- 007
- ta
- 008
- 141006s2014 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14712/23362936.2014.4 $2 doi
- 035 __
- $a (PubMed)24874933
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Neocleous, Charalambos $u Department of Medical Pediatrics, General Hospital of Drama, Drama, Greece
- 245 12
- $a A comparison between transcutaneous and total serum bilirubin in healthy-term greek neonates with clinical jaundice / $c C. Neocleous, A. Adramerina, S. Limnaios, S. Symeonidis, C. Spanou, M. Malakozi, E. Mpampalis
- 520 9_
- $a The accuracy of transcutaneous bilirubin meters has been assessed in newborns from various ethnic backgrounds. However, there are limited data on Greek newborns. Our study examined the accuracy of transcutaneous bilirubin measurements in clinically jaundiced healthy-term Greek newborns, using total serum bilirubin as the reference standard, in order to re-evaluate our local guidelines about neonatal jaundice. Clinically jaundiced newborns requiring total serum bilirubin level estimation were recruited prospectively. 368 pairs of total serum bilirubin/transcutaneous bilirubin measurements were taken in 222 newborns, using a direct spectrophotometric device and the BiliCheck device, respectively. The level of agreement between the obtained transcutaneous bilirubin and total serum bilirubin values was assessed. Our data were analysed using the Stata/SE 12.0 (StataCorp LP, USA) statistical programme. The mean (± SD) TSB was 225.4 ± 25.4 μmol/l and the mean (± SD) TcB was 237.9 ± 21.0 μmol/l. The correlation between the values was poor (Pearson's correlation coefficient 0.439; Lin's concordance coefficient 0.377 [95% CI 0.301 to 0.453]; P<0.001). The Bland-Altman analysis demonstrated that transcutaneous bilirubin measurements tended to overestimate the total serum bilirubin value (mean difference 12.5 ± 24.9 μmol/l), with wide 95% limits of agreement (-36.2 μmol/l to 61.3 μmol/l). Transcutaneous bilirubin values did not correlate well with total serum bilirubin values, being often imprecise in predicting the actual total serum bilirubin levels. This permits us to continue estimating total serum bilirubin in clinically jaundiced newborns according to our local guidelines, in order to safely decide the appropriate care plan.
- 650 _2
- $a bilirubin $x analýza $x metabolismus $7 D001663
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a čelo $7 D005546
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a novorozenec $7 D007231
- 650 _2
- $a novorozenecká žloutenka $x diagnóza $x metabolismus $7 D007567
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a novorozenecký screening $x přístrojové vybavení $7 D015997
- 650 _2
- $a prospektivní studie $7 D011446
- 651 _2
- $a Řecko $7 D006115
- 655 _2
- $a klinické zkoušky $7 D016430
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Adramerina, Alkistis $u Department of Medical Pediatrics, General Hospital of Drama, Drama, Greece $7 gn_A_00001892
- 700 1_
- $a Limnaios, Stefanos $u Department of Medical Pediatrics, General Hospital of Drama, Drama, Greece
- 700 1_
- $a Symeonidis, Symeon $u Department of Medical Pediatrics, General Hospital of Drama, Drama, Greece
- 700 1_
- $a Spanou, Chrysoula $u Department of Medical Pediatrics, General Hospital of Drama, Drama, Greece
- 700 1_
- $a Malakozi, Marina $u Department of Medical Pediatrics, General Hospital of Drama, Drama, Greece
- 700 1_
- $a Mpampalis, Evangelos $u Department of Medical Pediatrics, General Hospital of Drama, Drama, Greece
- 773 0_
- $w MED00013414 $t Prague medical report $x 1214-6994 $g Roč. 115, č. 1-2 (2014), s. 33-42
- 856 41
- $u https://pmr.lf1.cuni.cz/media/pdf/pmr_2014115010033.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 7 $c 1071 $y 4 $z 0
- 990 __
- $a 20141006 $b ABA008
- 991 __
- $a 20141013102356 $b ABA008
- 999 __
- $a ok $b bmc $g 1043415 $s 873007
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 115 $c 1-2 $d 33-42 $i 1214-6994 $m Prague Medical Report $n Prague Med. Rep. $x MED00013414
- LZP __
- $b NLK118 $a Pubmed-20141006