The effect of dead elements on the accuracy of Doppler ultrasound measurements

J. Vachutka, L. Dolezal, C. Kollmann, J. Klein,

. 2014 ; 36 (1) : 18-34.

Language English Country England, Great Britain

Document type Journal Article, Research Support, Non-U.S. Gov't

The objective of this study is to investigate the effect of multiple dead elements in an ultrasound probe on the accuracy of Doppler ultrasound measurements. For this work, we used a specially designed ultrasound imaging system, the Ultrasonix Sonix RP, that provides the user with the ability to disable selected elements in the probe. Using fully functional convex, linear, and phased array probes, we established a performance baseline by measuring the parameters of a laminar parabolic flow profile. These same parameters were then measured using probes with 1 to 10 disabled elements. The acquired velocity spectra from the functional probes and the probes with disabled elements were then analyzed to determine the overall Doppler power, maximum flow velocity, and average flow velocity. Color Flow Doppler images were also evaluated in a similar manner. The analysis of the Doppler spectra indicates that the overall Doppler power as well as the detected maximum and average velocities decrease with the increasing number of disabled elements. With multiple disabled elements, decreases in the detected maximum and average velocities greater than 20% were recorded. Similar results were also observed with Color Flow Doppler measurements. Our results confirmed that the degradation of the ultrasound probe through the loss of viable elements will negatively affect the quality of the Doppler-derived diagnostic information. We conclude that the results of Doppler measurements cannot be considered accurate or reliable if there are four or more contiguous dead elements in any given probe.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14074473
003      
CZ-PrNML
005      
20141008104349.0
007      
ta
008      
141006s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1177/0161734613508933 $2 doi
035    __
$a (PubMed)24275537
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Vachutka, Jaromir $u 1Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic.
245    14
$a The effect of dead elements on the accuracy of Doppler ultrasound measurements / $c J. Vachutka, L. Dolezal, C. Kollmann, J. Klein,
520    9_
$a The objective of this study is to investigate the effect of multiple dead elements in an ultrasound probe on the accuracy of Doppler ultrasound measurements. For this work, we used a specially designed ultrasound imaging system, the Ultrasonix Sonix RP, that provides the user with the ability to disable selected elements in the probe. Using fully functional convex, linear, and phased array probes, we established a performance baseline by measuring the parameters of a laminar parabolic flow profile. These same parameters were then measured using probes with 1 to 10 disabled elements. The acquired velocity spectra from the functional probes and the probes with disabled elements were then analyzed to determine the overall Doppler power, maximum flow velocity, and average flow velocity. Color Flow Doppler images were also evaluated in a similar manner. The analysis of the Doppler spectra indicates that the overall Doppler power as well as the detected maximum and average velocities decrease with the increasing number of disabled elements. With multiple disabled elements, decreases in the detected maximum and average velocities greater than 20% were recorded. Similar results were also observed with Color Flow Doppler measurements. Our results confirmed that the degradation of the ultrasound probe through the loss of viable elements will negatively affect the quality of the Doppler-derived diagnostic information. We conclude that the results of Doppler measurements cannot be considered accurate or reliable if there are four or more contiguous dead elements in any given probe.
650    _2
$a design vybavení $7 D004867
650    _2
$a selhání zařízení $7 D004868
650    _2
$a analýza selhání vybavení $x metody $x statistika a číselné údaje $7 D019544
650    _2
$a fantomy radiodiagnostické $7 D019047
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a ultrasonografie dopplerovská $x přístrojové vybavení $x metody $7 D018608
650    _2
$a ultrasonografie dopplerovská barevná $x přístrojové vybavení $x metody $7 D018615
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Dolezal, Ladislav
700    1_
$a Kollmann, Christian
700    1_
$a Klein, Jakob
773    0_
$w MED00004599 $t Ultrasonic imaging $x 1096-0910 $g Roč. 36, č. 1 (2014), s. 18-34
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24275537 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20141006 $b ABA008
991    __
$a 20141008104737 $b ABA008
999    __
$a ok $b bmc $g 1042356 $s 873385
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 36 $c 1 $d 18-34 $i 1096-0910 $m Ultrasonic imaging $n Ultrason Imaging $x MED00004599
LZP    __
$a Pubmed-20141006

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...