-
Something wrong with this record ?
Diagnostic accuracy of the Berlin Questionnaire in detecting sleep-disordered breathing in patients with a recent myocardial infarction
FH. Sert Kuniyoshi, MR. Zellmer, AD. Calvin, F. Lopez-Jimenez, FN. Albuquerque, C. van der Walt, IC. Trombetta, SM. Caples, AS. Shamsuzzaman, J. Bukartyk, T. Konecny, AS. Gami, T. Kara, VK. Somers,
Language English Country United States
Document type Journal Article, Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't
Grant support
NS10098
MZ0
CEP Register
PubMed
21596794
DOI
10.1378/chest.10-2625
Knihovny.cz E-resources
- MeSH
- Myocardial Infarction complications MeSH
- Comorbidity MeSH
- Middle Aged MeSH
- Humans MeSH
- Statistics, Nonparametric MeSH
- Area Under Curve MeSH
- Polysomnography MeSH
- Predictive Value of Tests MeSH
- Cross-Sectional Studies MeSH
- Surveys and Questionnaires * MeSH
- Reproducibility of Results MeSH
- Sensitivity and Specificity MeSH
- Sleep Apnea Syndromes diagnosis MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Research Support, N.I.H., Extramural MeSH
BACKGROUND: The Berlin Questionnaire (BQ) has been used to identify patients at high risk for sleep-disordered breathing (SDB) in a variety of populations. However, there are no data regarding the validity of the BQ in detecting the presence of SDB in patients after myocardial infarction (MI). The aim of this study was to determine the performance of the BQ in patients after MI. METHODS: We conducted a cross-sectional study of 99 patients who had an MI 1 to 3 months previously. The BQ was administered, scored using the published methods, and followed by completed overnight polysomnography as the "gold standard." SDB was defined as an apnea-hypopnea index of ≥ 5 events/h. The sensitivity, specificity, and positive and negative predictive values of the BQ were calculated. RESULTS: Of the 99 patients, the BQ identified 64 (65%) as being at high-risk for having SDB. Overnight polysomnography showed that 73 (73%) had SDB. The BQ sensitivity and specificity was 0.68 and 0.34, respectively, with a positive predictive value of 0.68 and a negative predictive value of 0.50. Positive and negative likelihood ratios were 1.27 and 0.68, respectively, and the BQ overall diagnostic accuracy was 63%. Using different apnea-hypopnea index cutoff values did not meaningfully alter these results. CONCLUSION: The BQ performed with modest sensitivity, but the specificity was poor, suggesting that the BQ is not ideal in identifying SDB in patients with a recent MI.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14076683
- 003
- CZ-PrNML
- 005
- 20141023125507.0
- 007
- ta
- 008
- 141023s2011 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1378/chest.10-2625 $2 doi
- 035 __
- $a (PubMed)21596794
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Sert Kuniyoshi, Fatima H $u Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic and Foundation, Rochester, MN, USA.
- 245 10
- $a Diagnostic accuracy of the Berlin Questionnaire in detecting sleep-disordered breathing in patients with a recent myocardial infarction / $c FH. Sert Kuniyoshi, MR. Zellmer, AD. Calvin, F. Lopez-Jimenez, FN. Albuquerque, C. van der Walt, IC. Trombetta, SM. Caples, AS. Shamsuzzaman, J. Bukartyk, T. Konecny, AS. Gami, T. Kara, VK. Somers,
- 520 9_
- $a BACKGROUND: The Berlin Questionnaire (BQ) has been used to identify patients at high risk for sleep-disordered breathing (SDB) in a variety of populations. However, there are no data regarding the validity of the BQ in detecting the presence of SDB in patients after myocardial infarction (MI). The aim of this study was to determine the performance of the BQ in patients after MI. METHODS: We conducted a cross-sectional study of 99 patients who had an MI 1 to 3 months previously. The BQ was administered, scored using the published methods, and followed by completed overnight polysomnography as the "gold standard." SDB was defined as an apnea-hypopnea index of ≥ 5 events/h. The sensitivity, specificity, and positive and negative predictive values of the BQ were calculated. RESULTS: Of the 99 patients, the BQ identified 64 (65%) as being at high-risk for having SDB. Overnight polysomnography showed that 73 (73%) had SDB. The BQ sensitivity and specificity was 0.68 and 0.34, respectively, with a positive predictive value of 0.68 and a negative predictive value of 0.50. Positive and negative likelihood ratios were 1.27 and 0.68, respectively, and the BQ overall diagnostic accuracy was 63%. Using different apnea-hypopnea index cutoff values did not meaningfully alter these results. CONCLUSION: The BQ performed with modest sensitivity, but the specificity was poor, suggesting that the BQ is not ideal in identifying SDB in patients with a recent MI.
- 650 _2
- $a plocha pod křivkou $7 D019540
- 650 _2
- $a komorbidita $7 D015897
- 650 _2
- $a průřezové studie $7 D003430
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a infarkt myokardu $x komplikace $7 D009203
- 650 _2
- $a polysomnografie $7 D017286
- 650 _2
- $a prediktivní hodnota testů $7 D011237
- 650 12
- $a průzkumy a dotazníky $7 D011795
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a syndromy spánkové apnoe $x diagnóza $7 D012891
- 650 _2
- $a neparametrická statistika $7 D018709
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a Research Support, N.I.H., Extramural $7 D052061
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Zellmer, Mark R
- 700 1_
- $a Calvin, Andrew D
- 700 1_
- $a Lopez-Jimenez, Francisco
- 700 1_
- $a Albuquerque, Felipe N $7 gn_A_00003596
- 700 1_
- $a van der Walt, Christelle
- 700 1_
- $a Trombetta, Ivani C
- 700 1_
- $a Caples, Sean M
- 700 1_
- $a Shamsuzzaman, Abu S
- 700 1_
- $a Bukartyk, Jan
- 700 1_
- $a Konecny, Tomas
- 700 1_
- $a Gami, Apoor S
- 700 1_
- $a Kara, Tomas
- 700 1_
- $a Somers, Virend K
- 773 0_
- $w MED00002127 $t Chest $x 1931-3543 $g Roč. 140, č. 5 (2011), s. 1192-7
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21596794 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20141023 $b ABA008
- 991 __
- $a 20141023125506 $b ABA008
- 999 __
- $a ok $b bmc $g 1044753 $s 875629
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 140 $c 5 $d 1192-7 $i 1931-3543 $m Chest $n Chest $x MED00002127
- GRA __
- $a NS10098 $p MZ0
- LZP __
- $a Pubmed-20141023