Quantification of structural changes of UHMWPE components in total joint replacements

P. Fulin, D. Pokorny, M. Slouf, M. Nevoralova, T. Vackova, J. Dybal, J. Pilar,

. 2014 ; 15 (-) : 109.

Language English Country England, Great Britain

Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't

Grant support
NT12229 MZ0 CEP Register

BACKGROUND: At present time the number of implantations of joint replacements as well as their revisions increases. Higher demands are required on the quality and longevity of implants. The aim of this work was to determine the degree of oxidative degradation and the amount of free/residual radicals in selected ultra-high molecular weight polyethylene (UHMWPE) components of the joint replacements and demonstrate that the measured values are closely connected with quality and lifetime of the polymer components. METHODS: We tested both new (4 samples) and explanted (4 samples) UHMWPE polymers for total joint replacements. The samples were characterized by infrared spectroscopy (IR), electron spin resonance (ESR) and microhardness (MH) test. The IR measurements yielded the values of oxidation index and trans-vinylene index. The ESR measurements gave the free radicals concentration. RESULTS: In the group of new polyethylene components, we found oxidation index values ranging from 0.00-0.03 to 0.24. The trans-vinylene index values ranged from 0.044 to 0.080. The value of free radical concentration was zero in virgin and also in sample of Beznoska Company and non-zero in the other samples. In the group of explanted components, the measured values were associated with their history, micromechanical properties and performance in vivo. CONCLUSIONS: We demonstrated that measuring of oxidative damage may help the orthopaedic surgeon in estimating the quality of UHMWPE replacement component and thus radically to avoid early joint replacement failure due to worse polyethylene quality.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15008155
003      
CZ-PrNML
005      
20240117103639.0
007      
ta
008      
150306s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1186/1471-2474-15-109 $2 doi
035    __
$a (PubMed)24678698
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Fulín, Petr $u Department of Orthopaedics, First Faculty of Medicine, Charles University in Prague, V Úvalu 84, Prague 5 15006, Czech Republic. petrfulin@gmail.com. $7 xx0231618
245    10
$a Quantification of structural changes of UHMWPE components in total joint replacements / $c P. Fulin, D. Pokorny, M. Slouf, M. Nevoralova, T. Vackova, J. Dybal, J. Pilar,
520    9_
$a BACKGROUND: At present time the number of implantations of joint replacements as well as their revisions increases. Higher demands are required on the quality and longevity of implants. The aim of this work was to determine the degree of oxidative degradation and the amount of free/residual radicals in selected ultra-high molecular weight polyethylene (UHMWPE) components of the joint replacements and demonstrate that the measured values are closely connected with quality and lifetime of the polymer components. METHODS: We tested both new (4 samples) and explanted (4 samples) UHMWPE polymers for total joint replacements. The samples were characterized by infrared spectroscopy (IR), electron spin resonance (ESR) and microhardness (MH) test. The IR measurements yielded the values of oxidation index and trans-vinylene index. The ESR measurements gave the free radicals concentration. RESULTS: In the group of new polyethylene components, we found oxidation index values ranging from 0.00-0.03 to 0.24. The trans-vinylene index values ranged from 0.044 to 0.080. The value of free radical concentration was zero in virgin and also in sample of Beznoska Company and non-zero in the other samples. In the group of explanted components, the measured values were associated with their history, micromechanical properties and performance in vivo. CONCLUSIONS: We demonstrated that measuring of oxidative damage may help the orthopaedic surgeon in estimating the quality of UHMWPE replacement component and thus radically to avoid early joint replacement failure due to worse polyethylene quality.
650    _2
$a biokompatibilní materiály $x chemie $7 D001672
650    _2
$a krystalizace $7 D003460
650    _2
$a elektronová paramagnetická rezonance $7 D004578
650    _2
$a volné radikály $x analýza $7 D005609
650    _2
$a tvrdost $7 D006244
650    12
$a kyčelní protézy $7 D006622
650    _2
$a lidé $7 D006801
650    12
$a protézy kolene $7 D007720
650    _2
$a testování materiálů $7 D008422
650    _2
$a oxidace-redukce $7 D010084
650    _2
$a polyethyleny $x chemie $7 D011095
650    _2
$a selhání protézy $7 D011475
650    _2
$a reoperace $7 D012086
650    _2
$a spektrofotometrie infračervená $7 D013055
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Pokorný, David, $d 1968- $7 jn20001103568
700    1_
$a Šlouf, Miroslav, $d 1973- $7 xx0107048
700    1_
$a Nevoralová, Martina $7 ntka173525
700    1_
$a Vacková, Taťana $7 _AN076109
700    1_
$a Dybal, Jiří $7 xx0312810
700    1_
$a Pilař, Jan $7 _AN076112
773    0_
$w MED00008193 $t BMC musculoskeletal disorders $x 1471-2474 $g Roč. 15, č. - (2014), s. 109
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24678698 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150306 $b ABA008
991    __
$a 20240117103635 $b ABA008
999    __
$a ok $b bmc $g 1065428 $s 890955
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 15 $c - $d 109 $i 1471-2474 $m BMC musculoskeletal disorders $n BMC Musculoskelet Disord $x MED00008193
GRA    __
$a NT12229 $p MZ0
LZP    __
$a Pubmed-20150306

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...