• Je něco špatně v tomto záznamu ?

Indirect photometric detection of boron cluster anions electrophoretically separated in methanol

L. Vítová, L. Fojt, R. Vespalec,

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc15008189

3,5-Dinitrobenzoate and picrate are light absorbing anions pertinent to indirect photometric detection of boron cluster anions in buffered methanolic background electrolytes (BGEs). Tris(hydroxymethyl)aminomethane and morpholine have been used as buffering bases, which eliminated baseline steps, and minimized the baseline noise. In methanolic BGEs, mobilities of boron cluster anions depend on both ionic constituents of the BGE buffer. This dependence can be explained by ion pair interaction of detected anions with BGE cations, which are not bonded into ion pairs with the BGE anions. The former ion pair interaction decreases sensitivity of the indirect photometric detection.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15008189
003      
CZ-PrNML
005      
20150306133004.0
007      
ta
008      
150306s2014 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2014.02.060 $2 doi
035    __
$a (PubMed)24630978
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Vítová, Lada $u Institute of Biophysics, Academy of Sciences of the Czech Republic, v.v.i., Královopolská 135, 612 35 Brno, Czech Republic.
245    10
$a Indirect photometric detection of boron cluster anions electrophoretically separated in methanol / $c L. Vítová, L. Fojt, R. Vespalec,
520    9_
$a 3,5-Dinitrobenzoate and picrate are light absorbing anions pertinent to indirect photometric detection of boron cluster anions in buffered methanolic background electrolytes (BGEs). Tris(hydroxymethyl)aminomethane and morpholine have been used as buffering bases, which eliminated baseline steps, and minimized the baseline noise. In methanolic BGEs, mobilities of boron cluster anions depend on both ionic constituents of the BGE buffer. This dependence can be explained by ion pair interaction of detected anions with BGE cations, which are not bonded into ion pairs with the BGE anions. The former ion pair interaction decreases sensitivity of the indirect photometric detection.
650    _2
$a anionty $x chemie $7 D000838
650    _2
$a bor $x chemie $7 D001895
650    _2
$a elektrolyty $7 D004573
650    _2
$a elektroforéza kapilární $x metody $7 D019075
650    _2
$a methanol $x chemie $7 D000432
650    _2
$a fotometrie $x metody $7 D010783
650    _2
$a tromethamin $x chemie $7 D014325
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Fojt, Lukáš $u Institute of Biophysics, Academy of Sciences of the Czech Republic, v.v.i., Královopolská 135, 612 35 Brno, Czech Republic.
700    1_
$a Vespalec, Radim $u Institute of Biophysics, Academy of Sciences of the Czech Republic, v.v.i., Královopolská 135, 612 35 Brno, Czech Republic. Electronic address: vespalec@ibp.cz.
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1338, č. - (2014), s. 174-83
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24630978 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150306 $b ABA008
991    __
$a 20150306133235 $b ABA008
999    __
$a ok $b bmc $g 1065462 $s 890989
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 1338 $c - $d 174-83 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20150306

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...