-
Je něco špatně v tomto záznamu ?
Comparison of constitutive models of arterial layers with distributed collagen fibre orientations
P. Skacel, J. Bursa,
Jazyk angličtina Země Polsko
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
NLK
Free Medical Journals
od 1999
Medline Complete (EBSCOhost)
od 2007-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1999
PubMed
25308192
Knihovny.cz E-zdroje
- MeSH
- anizotropie MeSH
- arterie fyziologie ultrastruktura MeSH
- fibrilární kolageny fyziologie ultrastruktura MeSH
- konformace proteinů MeSH
- lidé MeSH
- mechanický stres MeSH
- modely kardiovaskulární * MeSH
- modul pružnosti fyziologie MeSH
- pevnost v tahu fyziologie MeSH
- pevnost v tlaku fyziologie MeSH
- pevnost ve smyku fyziologie MeSH
- počítačová simulace MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
Several constitutive models have been proposed for description of mechanical behaviour of soft tissues containing collagen fibres. The model with aligned fibres is modified in this paper to take the dispersion of fibre orientations into account through angular integration and it is compared with the model that is defined through generalized structure tensor. The paper is focused on the effect of fibre dispersion on the resulting stress-strain behaviour predicted by both models analyzed. Analytical calculations are used for the comparison of the mechanical behaviour under a specific biaxial tension mode. The two models have been implemented into commercial finite element code ANSYS via user subroutines and used for numerical simulation resulting in a non-homogeneous stress field. The effects of the fibre dispersion predicted by both models being compared differ significantly, e.g., the resulting stress difference between both models is lower than 10% only in the case of extremely small dispersion of collagen fibres orientation (κ< (0.01 to 0.03)). These results are consistent with those of other related literature. The applicability of the model defined through the generalized structure tensor is discussed.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15022963
- 003
- CZ-PrNML
- 005
- 20150722123508.0
- 007
- ta
- 008
- 150709s2014 pl f 000 0|eng||
- 009
- AR
- 035 __
- $a (PubMed)25308192
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a pl
- 100 1_
- $a Skacel, Pavel $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Brno, Czech Republic.
- 245 10
- $a Comparison of constitutive models of arterial layers with distributed collagen fibre orientations / $c P. Skacel, J. Bursa,
- 520 9_
- $a Several constitutive models have been proposed for description of mechanical behaviour of soft tissues containing collagen fibres. The model with aligned fibres is modified in this paper to take the dispersion of fibre orientations into account through angular integration and it is compared with the model that is defined through generalized structure tensor. The paper is focused on the effect of fibre dispersion on the resulting stress-strain behaviour predicted by both models analyzed. Analytical calculations are used for the comparison of the mechanical behaviour under a specific biaxial tension mode. The two models have been implemented into commercial finite element code ANSYS via user subroutines and used for numerical simulation resulting in a non-homogeneous stress field. The effects of the fibre dispersion predicted by both models being compared differ significantly, e.g., the resulting stress difference between both models is lower than 10% only in the case of extremely small dispersion of collagen fibres orientation (κ< (0.01 to 0.03)). These results are consistent with those of other related literature. The applicability of the model defined through the generalized structure tensor is discussed.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a anizotropie $7 D016880
- 650 _2
- $a arterie $x fyziologie $x ultrastruktura $7 D001158
- 650 _2
- $a pevnost v tlaku $x fyziologie $7 D019245
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a modul pružnosti $x fyziologie $7 D055119
- 650 _2
- $a fibrilární kolageny $x fyziologie $x ultrastruktura $7 D024022
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a modely kardiovaskulární $7 D008955
- 650 _2
- $a konformace proteinů $7 D011487
- 650 _2
- $a pevnost ve smyku $x fyziologie $7 D033081
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a pevnost v tahu $x fyziologie $7 D013718
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Bursa, Jiri $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Brno, Czech Republic.
- 773 0_
- $w MED00172317 $t Acta of bioengineering and biomechanics Wrocław University of Technology $x 1509-409X $g Roč. 16, č. 3 (2014), s. 47-58
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25308192 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150722123545 $b ABA008
- 999 __
- $a ok $b bmc $g 1083302 $s 905956
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 16 $c 3 $d 47-58 $i 1509-409X $m Acta of Bioengineering and Biomechanics $n Acta Bioeng Biomech $x MED00172317
- LZP __
- $a Pubmed-20150709