Effects of selected operational parameters on efficacy and selectivity of electromembrane extraction. Chlorophenols as model analytes
A. Slampová, P. Kubáň, P. Boček,
Language English Country Germany
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Chemical Fractionation instrumentation methods MeSH
- Models, Chemical * MeSH
- Chlorophenols analysis chemistry isolation & purification MeSH
- Electrophoresis instrumentation methods MeSH
- Limit of Detection MeSH
- Linear Models MeSH
- Membranes, Artificial * MeSH
- Reproducibility of Results MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Effects of organic solvent type, pH value, and composition of donor/acceptor solution on the efficacy of electromembrane extraction (EME) were examined. For the first time, a comprehensive quantitative study, based also on measurements of electric charge passed through the EME system, was carried out, which demonstrates that apart from the pH value, also the nature of counter-ions in donor and acceptor solution plays a significant role in the electrically induced transfer of charged analytes across supported liquid membranes (SLMs). The EME transfer of model analytes correlated well with electrophoretic mobilities of inorganic cations, which were added to acceptor solutions during their alkalization with alkali metal hydroxides, and were highest for counter-cations with highest mobilities. Up to a 53-fold improvement of extraction efficiency was achieved for EMEs using optimized composition of donor (alkalized with KOH to pH 7) and acceptor (10 mM CsOH, pH 12) solutions. Six chlorophenols (CPs) were selected as model analytes due to the wide range of pH values that are required for their ionization and due to their high environmental relevance; quantitative measurements were carried out by CE with UV detection. Extraction recoveries of the six CPs ranged between 14 and 25% for 5 min EMEs at 150 V and 750 rpm across SLMs impregnated with 1-ethyl-2-nitrobenzene. Calibration curves were strictly linear (r(2) ≥ 0.999) in 0.01-10 μg/mL range, repeatability values of peak areas were between 0.7 and 5.6% and LODs for standard solutions and environmental samples were better than 5 ng/mL.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15023445
- 003
- CZ-PrNML
- 005
- 20150730100513.0
- 007
- ta
- 008
- 150709s2014 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201400096 $2 doi
- 035 __
- $a (PubMed)24789309
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Slampová, Andrea $u Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, Brno, Czech Republic.
- 245 10
- $a Effects of selected operational parameters on efficacy and selectivity of electromembrane extraction. Chlorophenols as model analytes / $c A. Slampová, P. Kubáň, P. Boček,
- 520 9_
- $a Effects of organic solvent type, pH value, and composition of donor/acceptor solution on the efficacy of electromembrane extraction (EME) were examined. For the first time, a comprehensive quantitative study, based also on measurements of electric charge passed through the EME system, was carried out, which demonstrates that apart from the pH value, also the nature of counter-ions in donor and acceptor solution plays a significant role in the electrically induced transfer of charged analytes across supported liquid membranes (SLMs). The EME transfer of model analytes correlated well with electrophoretic mobilities of inorganic cations, which were added to acceptor solutions during their alkalization with alkali metal hydroxides, and were highest for counter-cations with highest mobilities. Up to a 53-fold improvement of extraction efficiency was achieved for EMEs using optimized composition of donor (alkalized with KOH to pH 7) and acceptor (10 mM CsOH, pH 12) solutions. Six chlorophenols (CPs) were selected as model analytes due to the wide range of pH values that are required for their ionization and due to their high environmental relevance; quantitative measurements were carried out by CE with UV detection. Extraction recoveries of the six CPs ranged between 14 and 25% for 5 min EMEs at 150 V and 750 rpm across SLMs impregnated with 1-ethyl-2-nitrobenzene. Calibration curves were strictly linear (r(2) ≥ 0.999) in 0.01-10 μg/mL range, repeatability values of peak areas were between 0.7 and 5.6% and LODs for standard solutions and environmental samples were better than 5 ng/mL.
- 650 _2
- $a chemická frakcionace $x přístrojové vybavení $x metody $7 D005591
- 650 _2
- $a chlorfenoly $x analýza $x chemie $x izolace a purifikace $7 D002733
- 650 _2
- $a elektroforéza $x přístrojové vybavení $x metody $7 D004586
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a lineární modely $7 D016014
- 650 12
- $a membrány umělé $7 D008567
- 650 12
- $a chemické modely $7 D008956
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kubáň, Pavel
- 700 1_
- $a Boček, Petr
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 35, č. 17 (2014), s. 2429-37
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24789309 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150730100601 $b ABA008
- 999 __
- $a ok $b bmc $g 1083782 $s 906438
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 35 $c 17 $d 2429-37 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20150709