Effects of selected operational parameters on efficacy and selectivity of electromembrane extraction. Chlorophenols as model analytes

A. Slampová, P. Kubáň, P. Boček,

. 2014 ; 35 (17) : 2429-37.

Language English Country Germany

Document type Journal Article, Research Support, Non-U.S. Gov't

Effects of organic solvent type, pH value, and composition of donor/acceptor solution on the efficacy of electromembrane extraction (EME) were examined. For the first time, a comprehensive quantitative study, based also on measurements of electric charge passed through the EME system, was carried out, which demonstrates that apart from the pH value, also the nature of counter-ions in donor and acceptor solution plays a significant role in the electrically induced transfer of charged analytes across supported liquid membranes (SLMs). The EME transfer of model analytes correlated well with electrophoretic mobilities of inorganic cations, which were added to acceptor solutions during their alkalization with alkali metal hydroxides, and were highest for counter-cations with highest mobilities. Up to a 53-fold improvement of extraction efficiency was achieved for EMEs using optimized composition of donor (alkalized with KOH to pH 7) and acceptor (10 mM CsOH, pH 12) solutions. Six chlorophenols (CPs) were selected as model analytes due to the wide range of pH values that are required for their ionization and due to their high environmental relevance; quantitative measurements were carried out by CE with UV detection. Extraction recoveries of the six CPs ranged between 14 and 25% for 5 min EMEs at 150 V and 750 rpm across SLMs impregnated with 1-ethyl-2-nitrobenzene. Calibration curves were strictly linear (r(2) ≥ 0.999) in 0.01-10 μg/mL range, repeatability values of peak areas were between 0.7 and 5.6% and LODs for standard solutions and environmental samples were better than 5 ng/mL.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15023445
003      
CZ-PrNML
005      
20150730100513.0
007      
ta
008      
150709s2014 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/elps.201400096 $2 doi
035    __
$a (PubMed)24789309
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Slampová, Andrea $u Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, Brno, Czech Republic.
245    10
$a Effects of selected operational parameters on efficacy and selectivity of electromembrane extraction. Chlorophenols as model analytes / $c A. Slampová, P. Kubáň, P. Boček,
520    9_
$a Effects of organic solvent type, pH value, and composition of donor/acceptor solution on the efficacy of electromembrane extraction (EME) were examined. For the first time, a comprehensive quantitative study, based also on measurements of electric charge passed through the EME system, was carried out, which demonstrates that apart from the pH value, also the nature of counter-ions in donor and acceptor solution plays a significant role in the electrically induced transfer of charged analytes across supported liquid membranes (SLMs). The EME transfer of model analytes correlated well with electrophoretic mobilities of inorganic cations, which were added to acceptor solutions during their alkalization with alkali metal hydroxides, and were highest for counter-cations with highest mobilities. Up to a 53-fold improvement of extraction efficiency was achieved for EMEs using optimized composition of donor (alkalized with KOH to pH 7) and acceptor (10 mM CsOH, pH 12) solutions. Six chlorophenols (CPs) were selected as model analytes due to the wide range of pH values that are required for their ionization and due to their high environmental relevance; quantitative measurements were carried out by CE with UV detection. Extraction recoveries of the six CPs ranged between 14 and 25% for 5 min EMEs at 150 V and 750 rpm across SLMs impregnated with 1-ethyl-2-nitrobenzene. Calibration curves were strictly linear (r(2) ≥ 0.999) in 0.01-10 μg/mL range, repeatability values of peak areas were between 0.7 and 5.6% and LODs for standard solutions and environmental samples were better than 5 ng/mL.
650    _2
$a chemická frakcionace $x přístrojové vybavení $x metody $7 D005591
650    _2
$a chlorfenoly $x analýza $x chemie $x izolace a purifikace $7 D002733
650    _2
$a elektroforéza $x přístrojové vybavení $x metody $7 D004586
650    _2
$a limita detekce $7 D057230
650    _2
$a lineární modely $7 D016014
650    12
$a membrány umělé $7 D008567
650    12
$a chemické modely $7 D008956
650    _2
$a reprodukovatelnost výsledků $7 D015203
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Kubáň, Pavel
700    1_
$a Boček, Petr
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 35, č. 17 (2014), s. 2429-37
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24789309 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150709 $b ABA008
991    __
$a 20150730100601 $b ABA008
999    __
$a ok $b bmc $g 1083782 $s 906438
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 35 $c 17 $d 2429-37 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20150709

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...