• Something wrong with this record ?

Determination of critical assembly absolute power using post-irradiation activation measurement of week-lived fission products

M. Košťál, M. Švadlenková, J. Milčák, V. Rypar, M. Koleška,

. 2014 ; 89 (-) : 18-24.

Language English Country England, Great Britain

Document type Journal Article, Research Support, Non-U.S. Gov't

The work presents a detailed comparison of calculated and experimentally determined net peak areas of longer-living fission products after 100 h irradiation on a reactor with power of ~630 W and several days cooling. Specifically the nuclides studied are (140)Ba, (103)Ru, (131)I, (141)Ce, (95)Zr. The good agreement between the calculated and measured net peak areas, which is better than in determination using short lived (92)Sr, is reported. The experiment was conducted on the VVER-1000 mock-up installed on the LR-0 reactor. The Monte Carlo approach has been used for calculations. The influence of different data libraries on results of calculation is discussed as well.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15023561
003      
CZ-PrNML
005      
20240903143806.0
007      
ta
008      
150709s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.apradiso.2014.01.004 $2 doi
035    __
$a (PubMed)24566373
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Košťál, Michal $u Research Center Rez Ltd, 250 68 Husinec-Rez 130, Czech Republic. Electronic address: ksl@cvrez.cz.
245    10
$a Determination of critical assembly absolute power using post-irradiation activation measurement of week-lived fission products / $c M. Košťál, M. Švadlenková, J. Milčák, V. Rypar, M. Koleška,
520    9_
$a The work presents a detailed comparison of calculated and experimentally determined net peak areas of longer-living fission products after 100 h irradiation on a reactor with power of ~630 W and several days cooling. Specifically the nuclides studied are (140)Ba, (103)Ru, (131)I, (141)Ce, (95)Zr. The good agreement between the calculated and measured net peak areas, which is better than in determination using short lived (92)Sr, is reported. The experiment was conducted on the VVER-1000 mock-up installed on the LR-0 reactor. The Monte Carlo approach has been used for calculations. The influence of different data libraries on results of calculation is discussed as well.
650    _2
$a poločas $7 D006207
650    _2
$a metoda Monte Carlo $7 D009010
650    _2
$a atomové reaktory $x přístrojové vybavení $7 D009688
650    _2
$a radionuklidy $x chemie $7 D011868
650    _2
$a spektrometrie gama $7 D013051
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Švadlenková, Marie $u Research Center Rez Ltd, 250 68 Husinec-Rez 130, Czech Republic.
700    1_
$a Milčák, Ján $u Research Center Rez Ltd, 250 68 Husinec-Rez 130, Czech Republic. $7 xx0321739
700    1_
$a Rypar, Vojtěch $u Research Center Rez Ltd, 250 68 Husinec-Rez 130, Czech Republic.
700    1_
$a Koleška, Michal $u Research Center Rez Ltd, 250 68 Husinec-Rez 130, Czech Republic.
773    0_
$w MED00000499 $t Applied radiation and isotopes $x 1872-9800 $g Roč. 89 (2014), s. 18-24
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24566373 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150709 $b ABA008
991    __
$a 20240903143803 $b ABA008
999    __
$a ok $b bmc $g 1083898 $s 906554
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 89 $c - $d 18-24 $i 1872-9800 $m Applied radiation and isotopes $n Appl Radiat Isot $x MED00000499
LZP    __
$a Pubmed-20150709

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...