Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Multiplexní detekce psychotropních látek v laterálním toku na membráně s nanočásticemi zlata
[Nanoparticles based multiplex lateral flow immunoassay for detection of drugs of abuse]

B. Ďurčiová, A. Zolal, K. Syslová, P. Kačer

. 2016 ; 110 (10) : 708-715.

Language Czech Country Czech Republic

Document type Research Support, Non-U.S. Gov't

One step multiple test line lateral flow immunoassay was designed in a competitive format for the detection of drugs of abuse (namely morphine, 3,4-methylen-dioxymethamphetamine, phenycyclidine and amphetamine) from oral fluids. For the labeling of antibodies, gold nanoparticles produced by the Turkevich method were used. It was found that saliva contains mucin glycoproteins which cause non-specific interactions on test lines. These undesirable interactions can be influenced by higher pH, higher buffer capacity, and a choice of suitable detergent for the sample pad buffer in combination with suitable sample pad material. Optimized sample pad buffer contained 100 mM Tris and 0.5% sodium deoxycholate to yield pH 9.0. Screening of all the materials (mainly sample pad, conjugate pad) was performed and Fusion 5 was selected in order to develop rapid test able to provide results within 10 minutes. The other key advantage of this format of the test, as compared to other immunoassays, is its low cost and simplicity requiring no sample or reagent preparation and no photodetector for its measurement.

Nanoparticles based multiplex lateral flow immunoassay for detection of drugs of abuse

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc17008526
003      
CZ-PrNML
005      
20170427095639.0
007      
ta
008      
170303s2016 xr ad f 000 0|cze||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Ďurčiová, Barbora $7 _AN090546 $u Ústav organické technologie, Vysoká škola chemickotechnologická v Praze, Technická 5, 166 28 Praha 6
245    10
$a Multiplexní detekce psychotropních látek v laterálním toku na membráně s nanočásticemi zlata / $c B. Ďurčiová, A. Zolal, K. Syslová, P. Kačer
246    31
$a Nanoparticles based multiplex lateral flow immunoassay for detection of drugs of abuse
504    __
$a Literatura
520    9_
$a One step multiple test line lateral flow immunoassay was designed in a competitive format for the detection of drugs of abuse (namely morphine, 3,4-methylen-dioxymethamphetamine, phenycyclidine and amphetamine) from oral fluids. For the labeling of antibodies, gold nanoparticles produced by the Turkevich method were used. It was found that saliva contains mucin glycoproteins which cause non-specific interactions on test lines. These undesirable interactions can be influenced by higher pH, higher buffer capacity, and a choice of suitable detergent for the sample pad buffer in combination with suitable sample pad material. Optimized sample pad buffer contained 100 mM Tris and 0.5% sodium deoxycholate to yield pH 9.0. Screening of all the materials (mainly sample pad, conjugate pad) was performed and Fusion 5 was selected in order to develop rapid test able to provide results within 10 minutes. The other key advantage of this format of the test, as compared to other immunoassays, is its low cost and simplicity requiring no sample or reagent preparation and no photodetector for its measurement.
650    _2
$a psychotropní léky $x analýza $7 D011619
650    _2
$a sliny $7 D012463
650    _2
$a zlato $7 D006046
650    _2
$a nanočástice $7 D053758
650    _2
$a chromatografie afinitní $7 D002846
650    _2
$a muciny $x chemie $7 D009077
650    _2
$a odběr biologického vzorku $7 D013048
650    _2
$a imunochemie $7 D007120
650    _2
$a kyselina deoxycholová $7 D003840
650    _2
$a odhalování abúzu drog $x metody $x využití $7 D015813
650    _2
$a lidé $7 D006801
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Zolal, Aram $7 xx0310354 $u Ústav organické technologie, Vysoká škola chemickotechnologická v Praze, Technická 5, 166 28 Praha 6
700    1_
$a Syslová, Kamila $7 xx0145898 $u Ústav organické technologie, Vysoká škola chemickotechnologická v Praze, Technická 5, 166 28 Praha 6
700    1_
$a Kačer, Petr, $d 1969- $7 xx0081992 $u Ústav organické technologie, Vysoká škola chemickotechnologická v Praze, Technická 5, 166 28 Praha 6
773    0_
$t Chemické listy $x 0009-2770 $g Roč. 110, č. 10 (2016), s. 708-715 $w MED00011010
856    41
$u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/155/155 $y domovská stránka časopisu
910    __
$a ABA008 $b B 1918 $c 395 $y 4 $z 0
990    __
$a 20170303074935 $b ABA008
991    __
$a 20170427095959 $b ABA008
999    __
$a ok $b bmc $g 1191684 $s 969215
BAS    __
$a 3
BMC    __
$a 2016 $b 110 $c 10 $d 708-715 $i 0009-2770 $m Chemické listy $n Chem. Listy $x MED00011010
LZP    __
$c NLK137 $d 20170427 $a NLK 2017-15/vt

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...