Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model
P. Tavakkoli Avval, S. Samiezadeh, V. Klika, H. Bougherara,
Language English Country Netherlands
Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Finite Element Analysis MeSH
- Models, Biological * MeSH
- Biomechanical Phenomena MeSH
- Biomimetic Materials adverse effects MeSH
- Bone Density drug effects MeSH
- Hip Joint drug effects physiology surgery MeSH
- Hip Prosthesis adverse effects MeSH
- Stress, Mechanical * MeSH
- Elastic Modulus drug effects MeSH
- Nylons adverse effects chemistry MeSH
- Postoperative Period MeSH
- Bone Remodeling drug effects MeSH
- Alloys adverse effects MeSH
- Carbon chemistry MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
Periprosthetic bone loss in response to total hip arthroplasty is a serious complication compromising patient's life quality as it may cause the premature failure of the implant. Stress shielding as a result of an uneven load sharing between the hip implant and the bone is a key factor leading to bone density decrease. A number of composite hip implants have been designed so far to improve load sharing characteristics. However, they have rarely been investigated from the bone remodeling point of view to predict a long-term response. This is the first study that employed a mechano-biochemical model, which considers the coupling effect between mechanical loading and bone biochemistry, to investigate bone remodeling after composite hip implantation. In this study, periprosthetic bone remodeling in the presence of Carbon fiber polyamide 12 (CF/PA12), CoCrMo and Ti alloy implants was predicted and compared. Our findings revealed that the most significant periprosthetic bone loss in response to metallic implants occurs in Gruen zone 7 (-43% with CoCrMo; -35% with Ti) and 6 (-40% with CoCrMo; -29% with Ti), while zone 4 has the lowest bone density decrease with all three implants (-9%). Also, the results showed that in terms of bone remodeling, the composite hip implant is more advantageous over the metallic ones as it provides a more uniform density change across the bone and induces less stress shielding which consequently results in a lower post-operative bone loss (-9% with CF/PA12 implant compared to -27% and -21% with CoCrMo and Ti alloy implants, respectively).
Department of Mathematics FNSPE Czech Technical University Prague Prague Czech Republic
Department of Mechanical and Industrial Engineering Ryerson University Toronto ON Canada
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15031648
- 003
- CZ-PrNML
- 005
- 20151013120046.0
- 007
- ta
- 008
- 151005s2015 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jmbbm.2014.09.019 $2 doi
- 035 __
- $a (PubMed)25460403
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Tavakkoli Avval, Pouria $u Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada. Electronic address: ptavakko@ryerson.ca.
- 245 10
- $a Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model / $c P. Tavakkoli Avval, S. Samiezadeh, V. Klika, H. Bougherara,
- 520 9_
- $a Periprosthetic bone loss in response to total hip arthroplasty is a serious complication compromising patient's life quality as it may cause the premature failure of the implant. Stress shielding as a result of an uneven load sharing between the hip implant and the bone is a key factor leading to bone density decrease. A number of composite hip implants have been designed so far to improve load sharing characteristics. However, they have rarely been investigated from the bone remodeling point of view to predict a long-term response. This is the first study that employed a mechano-biochemical model, which considers the coupling effect between mechanical loading and bone biochemistry, to investigate bone remodeling after composite hip implantation. In this study, periprosthetic bone remodeling in the presence of Carbon fiber polyamide 12 (CF/PA12), CoCrMo and Ti alloy implants was predicted and compared. Our findings revealed that the most significant periprosthetic bone loss in response to metallic implants occurs in Gruen zone 7 (-43% with CoCrMo; -35% with Ti) and 6 (-40% with CoCrMo; -29% with Ti), while zone 4 has the lowest bone density decrease with all three implants (-9%). Also, the results showed that in terms of bone remodeling, the composite hip implant is more advantageous over the metallic ones as it provides a more uniform density change across the bone and induces less stress shielding which consequently results in a lower post-operative bone loss (-9% with CF/PA12 implant compared to -27% and -21% with CoCrMo and Ti alloy implants, respectively).
- 650 _2
- $a slitiny $x škodlivé účinky $7 D000497
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a biomimetické materiály $x škodlivé účinky $7 D040761
- 650 _2
- $a kostní denzita $x účinky léků $7 D015519
- 650 _2
- $a remodelace kosti $x účinky léků $7 D016723
- 650 _2
- $a uhlík $x chemie $7 D002244
- 650 _2
- $a modul pružnosti $x účinky léků $7 D055119
- 650 _2
- $a analýza metodou konečných prvků $7 D020342
- 650 _2
- $a kyčelní kloub $x účinky léků $x fyziologie $x chirurgie $7 D006621
- 650 _2
- $a kyčelní protézy $x škodlivé účinky $7 D006622
- 650 12
- $a biologické modely $7 D008954
- 650 _2
- $a nylony $x škodlivé účinky $x chemie $7 D009757
- 650 _2
- $a pooperační období $7 D011184
- 650 12
- $a mechanický stres $7 D013314
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Samiezadeh, Saeid $u Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada. Electronic address: saeid.samiezadeh@ryerson.ca.
- 700 1_
- $a Klika, Václav $u Department of Mathematics, FNSPE, Czech Technical University in Prague, Prague, Czech Republic. Electronic address: klika@it.cas.cz.
- 700 1_
- $a Bougherara, Habiba $u Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada. Electronic address: habiba.bougherara@ryerson.ca.
- 773 0_
- $w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 41, č. - (2015), s. 56-67
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25460403 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20151005 $b ABA008
- 991 __
- $a 20151013120236 $b ABA008
- 999 __
- $a ok $b bmc $g 1092524 $s 914774
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 41 $c - $d 56-67 $e 20141008 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
- LZP __
- $a Pubmed-20151005