Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model

P. Tavakkoli Avval, S. Samiezadeh, V. Klika, H. Bougherara,

. 2015 ; 41 (-) : 56-67. [pub] 20141008

Jazyk angličtina Země Nizozemsko

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc15031648

Periprosthetic bone loss in response to total hip arthroplasty is a serious complication compromising patient's life quality as it may cause the premature failure of the implant. Stress shielding as a result of an uneven load sharing between the hip implant and the bone is a key factor leading to bone density decrease. A number of composite hip implants have been designed so far to improve load sharing characteristics. However, they have rarely been investigated from the bone remodeling point of view to predict a long-term response. This is the first study that employed a mechano-biochemical model, which considers the coupling effect between mechanical loading and bone biochemistry, to investigate bone remodeling after composite hip implantation. In this study, periprosthetic bone remodeling in the presence of Carbon fiber polyamide 12 (CF/PA12), CoCrMo and Ti alloy implants was predicted and compared. Our findings revealed that the most significant periprosthetic bone loss in response to metallic implants occurs in Gruen zone 7 (-43% with CoCrMo; -35% with Ti) and 6 (-40% with CoCrMo; -29% with Ti), while zone 4 has the lowest bone density decrease with all three implants (-9%). Also, the results showed that in terms of bone remodeling, the composite hip implant is more advantageous over the metallic ones as it provides a more uniform density change across the bone and induces less stress shielding which consequently results in a lower post-operative bone loss (-9% with CF/PA12 implant compared to -27% and -21% with CoCrMo and Ti alloy implants, respectively).

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15031648
003      
CZ-PrNML
005      
20151013120046.0
007      
ta
008      
151005s2015 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jmbbm.2014.09.019 $2 doi
035    __
$a (PubMed)25460403
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Tavakkoli Avval, Pouria $u Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada. Electronic address: ptavakko@ryerson.ca.
245    10
$a Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model / $c P. Tavakkoli Avval, S. Samiezadeh, V. Klika, H. Bougherara,
520    9_
$a Periprosthetic bone loss in response to total hip arthroplasty is a serious complication compromising patient's life quality as it may cause the premature failure of the implant. Stress shielding as a result of an uneven load sharing between the hip implant and the bone is a key factor leading to bone density decrease. A number of composite hip implants have been designed so far to improve load sharing characteristics. However, they have rarely been investigated from the bone remodeling point of view to predict a long-term response. This is the first study that employed a mechano-biochemical model, which considers the coupling effect between mechanical loading and bone biochemistry, to investigate bone remodeling after composite hip implantation. In this study, periprosthetic bone remodeling in the presence of Carbon fiber polyamide 12 (CF/PA12), CoCrMo and Ti alloy implants was predicted and compared. Our findings revealed that the most significant periprosthetic bone loss in response to metallic implants occurs in Gruen zone 7 (-43% with CoCrMo; -35% with Ti) and 6 (-40% with CoCrMo; -29% with Ti), while zone 4 has the lowest bone density decrease with all three implants (-9%). Also, the results showed that in terms of bone remodeling, the composite hip implant is more advantageous over the metallic ones as it provides a more uniform density change across the bone and induces less stress shielding which consequently results in a lower post-operative bone loss (-9% with CF/PA12 implant compared to -27% and -21% with CoCrMo and Ti alloy implants, respectively).
650    _2
$a slitiny $x škodlivé účinky $7 D000497
650    _2
$a biomechanika $7 D001696
650    _2
$a biomimetické materiály $x škodlivé účinky $7 D040761
650    _2
$a kostní denzita $x účinky léků $7 D015519
650    _2
$a remodelace kosti $x účinky léků $7 D016723
650    _2
$a uhlík $x chemie $7 D002244
650    _2
$a modul pružnosti $x účinky léků $7 D055119
650    _2
$a analýza metodou konečných prvků $7 D020342
650    _2
$a kyčelní kloub $x účinky léků $x fyziologie $x chirurgie $7 D006621
650    _2
$a kyčelní protézy $x škodlivé účinky $7 D006622
650    12
$a biologické modely $7 D008954
650    _2
$a nylony $x škodlivé účinky $x chemie $7 D009757
650    _2
$a pooperační období $7 D011184
650    12
$a mechanický stres $7 D013314
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Samiezadeh, Saeid $u Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada. Electronic address: saeid.samiezadeh@ryerson.ca.
700    1_
$a Klika, Václav $u Department of Mathematics, FNSPE, Czech Technical University in Prague, Prague, Czech Republic. Electronic address: klika@it.cas.cz.
700    1_
$a Bougherara, Habiba $u Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada. Electronic address: habiba.bougherara@ryerson.ca.
773    0_
$w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 41, č. - (2015), s. 56-67
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25460403 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20151013120236 $b ABA008
999    __
$a ok $b bmc $g 1092524 $s 914774
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 41 $c - $d 56-67 $e 20141008 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
LZP    __
$a Pubmed-20151005

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...