Evaluation of three purely polypropylene meshes of different pore sizes in an onlay position in a New Zealand white rabbit model
J. Jerabek, T. Novotny, K. Vesely, J. Cagas, V. Jedlicka, P. Vlcek, I. Capov,
Jazyk angličtina Země Francie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
ProQuest Central
od 2001-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2003-03-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2001-01-01 do Před 1 rokem
- MeSH
- biokompatibilní materiály MeSH
- chirurgické síťky * škodlivé účinky MeSH
- granulom z cizího tělesa etiologie patologie MeSH
- králíci MeSH
- modely nemocí na zvířatech MeSH
- operace kýly * MeSH
- polypropyleny škodlivé účinky MeSH
- pružnost MeSH
- testování materiálů MeSH
- zánět MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: The aim of the study was to evaluate the influence of the pore size of a polypropylene mesh on the shrinkage and elasticity of the mesh-tissue complex and the inflammatory reaction to the implant in an open onlay hernia repair. MATERIALS AND METHODS: Twenty-one 10 × 10 cm samples of polypropylene meshes of a different pore size (3.0 × 2.8 mm-PP3, 1.0 × 0.8 mm-PP1 and 0.6 × 0.5 mm-PP.5) were implanted in an onlay position in 21 New Zealand white rabbits. After 90 days of implantation the shrinkage, elasticity and foreign body reaction (FBR) were assessed. RESULTS: The shrinkage of PP3 was 30.6 ± 4.3 %, PP1 49.3 ± 2.9 % and PP.5 49.5 ± 2.6 %. The shrinkage of PP3 was significantly lower (PP3 × PP1 p = 0.007, PP3 × PP.5 p = 0.005), PP1 and PP.5 were similar. The elasticity was similar. The strength of FBR in mesh pores was similar. The width of foreign body granuloma layers at the mesh-tissue interface was significantly reduced with increasing pore size (inner: PP3 10.1 ± 1.2; PP1 12.5 ± 2.9; PP.5 17.4 ± 5.2 and outer: PP3 21.2 ± 2.5; PP1 30.6 ± 6.3; PP.5 60.4 ± 14.9). All differences between the widths of granuloma layers were statistically significant (p < 0.010). One animal (PP1) was excluded because of a mesh infection. CONCLUSIONS: Implantation of polypropylene mesh of a pore size of 3 mm in an onlay position is associated with a significant reduction of shrinkage in comparison to a 1 mm pore lightweight and 0.5 mm pore heavyweight mesh. A pore size increase to 3 mm is not sufficient for an improvement of mesh-tissue complex elasticity in comparison to a 1 mm pore lightweight and 0.5 mm heavyweight mesh. Polypropylene mesh with enlarged pores to 3 mm is associated with a similar strength of FBR in mesh pores and a reduced foreign body granuloma in comparison to a 1 mm pore lightweight and 0.5 mm pore heavyweight mesh.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15031954
- 003
- CZ-PrNML
- 005
- 20151012110847.0
- 007
- ta
- 008
- 151005s2014 fr f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s10029-014-1278-9 $2 doi
- 035 __
- $a (PubMed)25033941
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a fr
- 100 1_
- $a Jerabek, J $u 1st Department of Surgery, St. Anne's University Hospital, Faculty of Medicine, Masaryk University, Pekarska 53, 656 91, Brno, Czech Republic, jiri.jerabek@fnusa.cz.
- 245 10
- $a Evaluation of three purely polypropylene meshes of different pore sizes in an onlay position in a New Zealand white rabbit model / $c J. Jerabek, T. Novotny, K. Vesely, J. Cagas, V. Jedlicka, P. Vlcek, I. Capov,
- 520 9_
- $a BACKGROUND: The aim of the study was to evaluate the influence of the pore size of a polypropylene mesh on the shrinkage and elasticity of the mesh-tissue complex and the inflammatory reaction to the implant in an open onlay hernia repair. MATERIALS AND METHODS: Twenty-one 10 × 10 cm samples of polypropylene meshes of a different pore size (3.0 × 2.8 mm-PP3, 1.0 × 0.8 mm-PP1 and 0.6 × 0.5 mm-PP.5) were implanted in an onlay position in 21 New Zealand white rabbits. After 90 days of implantation the shrinkage, elasticity and foreign body reaction (FBR) were assessed. RESULTS: The shrinkage of PP3 was 30.6 ± 4.3 %, PP1 49.3 ± 2.9 % and PP.5 49.5 ± 2.6 %. The shrinkage of PP3 was significantly lower (PP3 × PP1 p = 0.007, PP3 × PP.5 p = 0.005), PP1 and PP.5 were similar. The elasticity was similar. The strength of FBR in mesh pores was similar. The width of foreign body granuloma layers at the mesh-tissue interface was significantly reduced with increasing pore size (inner: PP3 10.1 ± 1.2; PP1 12.5 ± 2.9; PP.5 17.4 ± 5.2 and outer: PP3 21.2 ± 2.5; PP1 30.6 ± 6.3; PP.5 60.4 ± 14.9). All differences between the widths of granuloma layers were statistically significant (p < 0.010). One animal (PP1) was excluded because of a mesh infection. CONCLUSIONS: Implantation of polypropylene mesh of a pore size of 3 mm in an onlay position is associated with a significant reduction of shrinkage in comparison to a 1 mm pore lightweight and 0.5 mm pore heavyweight mesh. A pore size increase to 3 mm is not sufficient for an improvement of mesh-tissue complex elasticity in comparison to a 1 mm pore lightweight and 0.5 mm heavyweight mesh. Polypropylene mesh with enlarged pores to 3 mm is associated with a similar strength of FBR in mesh pores and a reduced foreign body granuloma in comparison to a 1 mm pore lightweight and 0.5 mm pore heavyweight mesh.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a biokompatibilní materiály $7 D001672
- 650 _2
- $a modely nemocí na zvířatech $7 D004195
- 650 _2
- $a pružnost $7 D004548
- 650 _2
- $a granulom z cizího tělesa $x etiologie $x patologie $7 D015745
- 650 12
- $a operace kýly $7 D059685
- 650 _2
- $a zánět $7 D007249
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a polypropyleny $x škodlivé účinky $7 D011126
- 650 _2
- $a králíci $7 D011817
- 650 12
- $a chirurgické síťky $x škodlivé účinky $7 D013526
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Novotny, T
- 700 1_
- $a Vesely, K
- 700 1_
- $a Cagas, J
- 700 1_
- $a Jedlicka, V
- 700 1_
- $a Vlcek, P
- 700 1_
- $a Capov, I
- 773 0_
- $w MED00005723 $t Hernia the journal of hernias and abdominal wall surgery $x 1248-9204 $g Roč. 18, č. 6 (2014), s. 855-64
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25033941 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20151005 $b ABA008
- 991 __
- $a 20151012111036 $b ABA008
- 999 __
- $a ok $b bmc $g 1092830 $s 915080
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 18 $c 6 $d 855-64 $e 20140718 $i 1248-9204 $m Hernia $n Hernia $x MED00005723
- LZP __
- $a Pubmed-20151005