• Something wrong with this record ?

Bone SPECT image reconstruction using deconvolution and wavelet transformation: development, performance assessment and comparison in phantom and patient study with standard OSEM and resolution recovery algorithm

J. Ptáček, L. Henzlová, P. Koranda,

. 2014 ; 30 (7) : 858-64. [pub] 20140630

Language English Country Italy

Document type Journal Article

PURPOSE: The aim of this work was to introduce a new algorithm for image reconstruction in bone SPECT and to compare its performances with a commercially available standard OSEM and resolution recovery (RR) reconstruction. MATERIALS AND METHODS: The algorithm was built applying the Lucy-Richardson deconvolution adn logarithmic image processing to the projections. A modification of the coefficients of wavelet decomposition was used to suppress the noise. The comparison with vendor software was performed both in a phantom study, using Signal-to-Noise ratio (SNR), Signal-to-Background ratio (SBR), spatial resolution and in clinical studies, by visual assessment of changes in contrast, spatial resolution and lesion detectability. RESULTS: A change in the SNR (from -4 to 40%), an increase in the SBR (from 19 to 40%), a minor improvement in spatial resolution and a similar noise level were observed in the phantom study in comparison to the standard OSEM. A decrease in the SNR, a worse spatial resolution, but only a 3 to 13 % lower SBR were achieved in comparison with the vendor supplied RR algorithm. The proposed algorithm creates patient images with better contrast and lesion detectability compared to clinically used OSEM. Compared to RR, more than half of obtained images showed better contrast and nearly half of them have better lesion detectability. CONCLUSION: The proposed algorithm compares favorably with the standard OSEM. Although less favorable, the comparison with RR and noise suppression algorithms, suggests that it can be used with only a slight decrease in the SBR.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15031972
003      
CZ-PrNML
005      
20151014105906.0
007      
ta
008      
151005s2014 it f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ejmp.2014.06.002 $2 doi
035    __
$a (PubMed)24989849
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a it
100    1_
$a Ptáček, Jaroslav $u Dept. of Nuclear Medicine, University Hospital Olomouc, Czech Republic; Dept. of Medical Physics and Radiation Protection, University Hospital Olomouc, Czech Republic. Electronic address: jaroslav.ptacek@fnol.cz.
245    10
$a Bone SPECT image reconstruction using deconvolution and wavelet transformation: development, performance assessment and comparison in phantom and patient study with standard OSEM and resolution recovery algorithm / $c J. Ptáček, L. Henzlová, P. Koranda,
520    9_
$a PURPOSE: The aim of this work was to introduce a new algorithm for image reconstruction in bone SPECT and to compare its performances with a commercially available standard OSEM and resolution recovery (RR) reconstruction. MATERIALS AND METHODS: The algorithm was built applying the Lucy-Richardson deconvolution adn logarithmic image processing to the projections. A modification of the coefficients of wavelet decomposition was used to suppress the noise. The comparison with vendor software was performed both in a phantom study, using Signal-to-Noise ratio (SNR), Signal-to-Background ratio (SBR), spatial resolution and in clinical studies, by visual assessment of changes in contrast, spatial resolution and lesion detectability. RESULTS: A change in the SNR (from -4 to 40%), an increase in the SBR (from 19 to 40%), a minor improvement in spatial resolution and a similar noise level were observed in the phantom study in comparison to the standard OSEM. A decrease in the SNR, a worse spatial resolution, but only a 3 to 13 % lower SBR were achieved in comparison with the vendor supplied RR algorithm. The proposed algorithm creates patient images with better contrast and lesion detectability compared to clinically used OSEM. Compared to RR, more than half of obtained images showed better contrast and nearly half of them have better lesion detectability. CONCLUSION: The proposed algorithm compares favorably with the standard OSEM. Although less favorable, the comparison with RR and noise suppression algorithms, suggests that it can be used with only a slight decrease in the SBR.
650    12
$a algoritmy $7 D000465
650    _2
$a kosti a kostní tkáň $x radioizotopová diagnostika $7 D001842
650    _2
$a lidé $7 D006801
650    _2
$a počítačové zpracování obrazu $x metody $7 D007091
650    12
$a fantomy radiodiagnostické $7 D019047
650    _2
$a poměr signál - šum $7 D059629
650    _2
$a jednofotonová emisní výpočetní tomografie $x přístrojové vybavení $7 D015899
650    12
$a vlnková analýza $7 D058067
655    _2
$a časopisecké články $7 D016428
700    1_
$a Henzlová, Lenka $u Dept. of Nuclear Medicine, University Hospital Olomouc, Czech Republic.
700    1_
$a Koranda, Pavel $u Dept. of Nuclear Medicine, University Hospital Olomouc, Czech Republic.
773    0_
$w MED00167391 $t Physica medica PM an international journal devoted to the applications of physics to medicine and biology official journal of the Italian Association of Biomedical Physics (AIFB) $x 1724-191X $g Roč. 30, č. 7 (2014), s. 858-64
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24989849 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20151014110056 $b ABA008
999    __
$a ok $b bmc $g 1092848 $s 915098
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 30 $c 7 $d 858-64 $e 20140630 $i 1724-191X $m Physica medica $n Phys Med $x MED00167391
LZP    __
$a Pubmed-20151005

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...