-
Je něco špatně v tomto záznamu ?
Lipidomics as an important key for the identification of beer-spoilage bacteria
T. Řezanka, D. Matoulková, O. Benada, K. Sigler,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
25773514
DOI
10.1111/lam.12415
Knihovny.cz E-zdroje
- MeSH
- hmotnostní spektrometrie s elektrosprejovou ionizací MeSH
- limita detekce MeSH
- Megasphaera klasifikace izolace a purifikace metabolismus MeSH
- Pectinatus klasifikace izolace a purifikace metabolismus MeSH
- pivo mikrobiologie MeSH
- plasmalogeny analýza MeSH
- potravinářská mikrobiologie metody MeSH
- tandemová hmotnostní spektrometrie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) was used for characterizing intact plasmalogen phospholipid molecules in beer-spoilage bacteria. Identification of intact plasmalogens was carried out using collision-induced dissociation and the presence of suitable marker molecular species, both qualitative and quantitative, was determined in samples containing the anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method had a limit of detection at 1 pg for the standard, i.e. 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and be linear in the range of four orders of magnitude from 2 pg to 20 ng. This technique was applied to intact plasmalogen extracts from the samples of contaminated and uncontaminated beer without derivatization and resulted in the identification of contamination of beer by Megasphaera and Pectinatus bacteria. The limit of detection was about 830 cells of anaerobic bacteria, i.e. bacteria containing natural cyclopropane plasmalogenes (c-p-19:0/15:0), which is the majority plasmalogen located in both Megasphaera and Pectinatus. The SIM ESI-MS method has been shown to be useful for the analysis of low concentration of plasmalogens in all biological samples, which were contaminated with anaerobic bacteria, e.g. juice, not only in beer. Significance and impact of the study: Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) using collision-induced dissociation was used to characterize intact plasmalogen phospholipid molecules in beer-spoilage anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method has a detection limit of 1 pg for the standard 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and is linear within four orders of magnitude (2 pg to 20 ng). The limit of detection was about 830 cells of bacteria containing natural cyclopropane plasmalogen (c-p-19:0/15:0). SIM ESI-MS method is useful for analyzing low concentrations of plasmalogens in biological samples contaminated with anaerobic bacteria, e.g. beer or juice.
Institute of Microbiology Academy of Sciences of the Czech Republic Prague Czech Republic
Research Institute of Brewing and Malting Prague Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000209
- 003
- CZ-PrNML
- 005
- 20160126110720.0
- 007
- ta
- 008
- 160108s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/lam.12415 $2 doi
- 035 __
- $a (PubMed)25773514
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Řezanka, T $u Institute of Microbiology, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
- 245 10
- $a Lipidomics as an important key for the identification of beer-spoilage bacteria / $c T. Řezanka, D. Matoulková, O. Benada, K. Sigler,
- 520 9_
- $a Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) was used for characterizing intact plasmalogen phospholipid molecules in beer-spoilage bacteria. Identification of intact plasmalogens was carried out using collision-induced dissociation and the presence of suitable marker molecular species, both qualitative and quantitative, was determined in samples containing the anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method had a limit of detection at 1 pg for the standard, i.e. 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and be linear in the range of four orders of magnitude from 2 pg to 20 ng. This technique was applied to intact plasmalogen extracts from the samples of contaminated and uncontaminated beer without derivatization and resulted in the identification of contamination of beer by Megasphaera and Pectinatus bacteria. The limit of detection was about 830 cells of anaerobic bacteria, i.e. bacteria containing natural cyclopropane plasmalogenes (c-p-19:0/15:0), which is the majority plasmalogen located in both Megasphaera and Pectinatus. The SIM ESI-MS method has been shown to be useful for the analysis of low concentration of plasmalogens in all biological samples, which were contaminated with anaerobic bacteria, e.g. juice, not only in beer. Significance and impact of the study: Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) using collision-induced dissociation was used to characterize intact plasmalogen phospholipid molecules in beer-spoilage anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method has a detection limit of 1 pg for the standard 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and is linear within four orders of magnitude (2 pg to 20 ng). The limit of detection was about 830 cells of bacteria containing natural cyclopropane plasmalogen (c-p-19:0/15:0). SIM ESI-MS method is useful for analyzing low concentrations of plasmalogens in biological samples contaminated with anaerobic bacteria, e.g. beer or juice.
- 650 _2
- $a pivo $x mikrobiologie $7 D001515
- 650 _2
- $a potravinářská mikrobiologie $x metody $7 D005516
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a Megasphaera $x klasifikace $x izolace a purifikace $x metabolismus $7 D045851
- 650 _2
- $a Pectinatus $x klasifikace $x izolace a purifikace $x metabolismus $7 D045852
- 650 _2
- $a plasmalogeny $x analýza $7 D010955
- 650 _2
- $a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
- 650 _2
- $a tandemová hmotnostní spektrometrie $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Matoulková, D $u Research Institute of Brewing and Malting, Prague, Czech Republic.
- 700 1_
- $a Benada, O $u Institute of Microbiology, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
- 700 1_
- $a Sigler, K $u Institute of Microbiology, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
- 773 0_
- $w MED00003137 $t Letters in applied microbiology $x 1472-765X $g Roč. 60, č. 6 (2015), s. 536-43
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25773514 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20160126110844 $b ABA008
- 999 __
- $a ok $b bmc $g 1102490 $s 924415
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 60 $c 6 $d 536-43 $e 20150408 $i 1472-765X $m Letters in applied microbiology $n Lett Appl Microbiol $x MED00003137
- LZP __
- $a Pubmed-20160108