Something wrong with this record ?
Structure-based constitutive model can accurately predict planar biaxial properties of aortic wall tissue
S. Polzer, TC. Gasser, K. Novak, V. Man, M. Tichy, P. Skacel, J. Bursa,
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Aorta, Thoracic anatomy & histology physiology MeSH
- Models, Biological * MeSH
- Biomechanical Phenomena MeSH
- Collagen metabolism MeSH
- Stress, Mechanical MeSH
- Reproducibility of Results MeSH
- Sus scrofa MeSH
- Animals MeSH
- Check Tag
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Structure-based constitutive models might help in exploring mechanisms by which arterial wall histology is linked to wall mechanics. This study aims to validate a recently proposed structure-based constitutive model. Specifically, the model's ability to predict mechanical biaxial response of porcine aortic tissue with predefined collagen structure was tested. Histological slices from porcine thoracic aorta wall (n=9) were automatically processed to quantify the collagen fiber organization, and mechanical testing identified the non-linear properties of the wall samples (n=18) over a wide range of biaxial stretches. Histological and mechanical experimental data were used to identify the model parameters of a recently proposed multi-scale constitutive description for arterial layers. The model predictive capability was tested with respect to interpolation and extrapolation. Collagen in the media was predominantly aligned in circumferential direction (planar von Mises distribution with concentration parameter bM=1.03 ± 0.23), and its coherence decreased gradually from the luminal to the abluminal tissue layers (inner media, b=1.54 ± 0.40; outer media, b=0.72 ± 0.20). In contrast, the collagen in the adventitia was aligned almost isotropically (bA=0.27 ± 0.11), and no features, such as families of coherent fibers, were identified. The applied constitutive model captured the aorta biaxial properties accurately (coefficient of determination R(2)=0.95 ± 0.03) over the entire range of biaxial deformations and with physically meaningful model parameters. Good predictive properties, well outside the parameter identification space, were observed (R(2)=0.92 ± 0.04). Multi-scale constitutive models equipped with realistic micro-histological data can predict macroscopic non-linear aorta wall properties. Collagen largely defines already low strain properties of media, which explains the origin of wall anisotropy seen at this strain level. The structure and mechanical properties of adventitia are well designed to protect the media from axial and circumferential overloads.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000499
- 003
- CZ-PrNML
- 005
- 20160121112936.0
- 007
- ta
- 008
- 160108s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.actbio.2014.11.043 $2 doi
- 035 __
- $a (PubMed)25458466
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Polzer, S $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Technicka 2896/2, 616 69, Brno University of Technology, Czech Republic. Electronic address: polzer@seznam.cz.
- 245 10
- $a Structure-based constitutive model can accurately predict planar biaxial properties of aortic wall tissue / $c S. Polzer, TC. Gasser, K. Novak, V. Man, M. Tichy, P. Skacel, J. Bursa,
- 520 9_
- $a Structure-based constitutive models might help in exploring mechanisms by which arterial wall histology is linked to wall mechanics. This study aims to validate a recently proposed structure-based constitutive model. Specifically, the model's ability to predict mechanical biaxial response of porcine aortic tissue with predefined collagen structure was tested. Histological slices from porcine thoracic aorta wall (n=9) were automatically processed to quantify the collagen fiber organization, and mechanical testing identified the non-linear properties of the wall samples (n=18) over a wide range of biaxial stretches. Histological and mechanical experimental data were used to identify the model parameters of a recently proposed multi-scale constitutive description for arterial layers. The model predictive capability was tested with respect to interpolation and extrapolation. Collagen in the media was predominantly aligned in circumferential direction (planar von Mises distribution with concentration parameter bM=1.03 ± 0.23), and its coherence decreased gradually from the luminal to the abluminal tissue layers (inner media, b=1.54 ± 0.40; outer media, b=0.72 ± 0.20). In contrast, the collagen in the adventitia was aligned almost isotropically (bA=0.27 ± 0.11), and no features, such as families of coherent fibers, were identified. The applied constitutive model captured the aorta biaxial properties accurately (coefficient of determination R(2)=0.95 ± 0.03) over the entire range of biaxial deformations and with physically meaningful model parameters. Good predictive properties, well outside the parameter identification space, were observed (R(2)=0.92 ± 0.04). Multi-scale constitutive models equipped with realistic micro-histological data can predict macroscopic non-linear aorta wall properties. Collagen largely defines already low strain properties of media, which explains the origin of wall anisotropy seen at this strain level. The structure and mechanical properties of adventitia are well designed to protect the media from axial and circumferential overloads.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a aorta thoracica $x anatomie a histologie $x fyziologie $7 D001013
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a kolagen $x metabolismus $7 D003094
- 650 12
- $a biologické modely $7 D008954
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a Sus scrofa $7 D034421
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Gasser, T C $u Department of Solid Mechanics, The Royal Institute of Technology, Stockholm, Sweden.
- 700 1_
- $a Novak, K $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Technicka 2896/2, 616 69, Brno University of Technology, Czech Republic.
- 700 1_
- $a Man, V $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Technicka 2896/2, 616 69, Brno University of Technology, Czech Republic.
- 700 1_
- $a Tichy, M $u 1st Department of Pathological Anatomy, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Skacel, P $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Technicka 2896/2, 616 69, Brno University of Technology, Czech Republic.
- 700 1_
- $a Bursa, J $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Technicka 2896/2, 616 69, Brno University of Technology, Czech Republic.
- 773 0_
- $w MED00008542 $t Acta biomaterialia $x 1878-7568 $g Roč. 14, č. - (2015), s. 133-45
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25458466 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20160121113055 $b ABA008
- 999 __
- $a ok $b bmc $g 1102780 $s 924705
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 14 $c - $d 133-45 $e 20141129 $i 1878-7568 $m Acta biomaterialia $n Acta Biomater $x MED00008542
- LZP __
- $a Pubmed-20160108