-
Something wrong with this record ?
Stanovení nikotinové kyseliny a jejích metabolitů pomocí HPLC-MS/MS
[Analysis of nicotinic acid and its metabolites by HPLC-MS/MS]
K. Žantová, E. Tvrzická, M. Vecka, A. Žák
Language Czech Country Czech Republic
Document type Research Support, Non-U.S. Gov't
- MeSH
- Chemistry Techniques, Analytical * MeSH
- Plasma MeSH
- Nicotinic Acids * analysis pharmacokinetics metabolism adverse effects MeSH
- Humans MeSH
- Analytic Sample Preparation Methods MeSH
- Niacin analysis pharmacokinetics metabolism adverse effects MeSH
- Tandem Mass Spectrometry * methods instrumentation utilization MeSH
- Chromatography, High Pressure Liquid * methods instrumentation utilization MeSH
- Healthy Volunteers MeSH
- Check Tag
- Humans MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
Nicotinic acid is a hypolipidemic agent with pleiotropic effects. Its drug form with controlled release leads to pyridine metabolites associated with the risk of hepatotoxicity. The aim of the present study was to introduce a HPLC-MS method for the determination of nicotinic acid, nicotinamide, nicotinuric acid, N-methylnicotin¬amide, nicotinamide 1-oxide, 1-methyl-2-oxo-1,2-dihydro¬pyridine-5-carboxamide, and 1-methyl-4-oxo-1,4-dihydro¬pyridine-5-carboxamide in blood plasma or urine. The method is useful for the monitoring in hypolipidemic the¬rapy. We have compared calibration curves of individual metabolites using Hypercarb (graphite carbon) and Hypersil Silica (silicagel) columns. Both columns gave linear calibration curves for all the mentioned analytes (except for 1-methylnicotinamide) in the concentration range 102000 ng ml1. The calibration curve in blood plasma and urine measured with the Hypersil Silica column was linear in the range 204000 ng ml1 for all the tested analytes. The analysis time was 15 min with the column Hypercarb and 27 min with Hypersil Silica. Biological samples were extracted with sulfonated copolymer N-vinylpyrrolidone divinylbenzene. Reproducibility of the results for biological samples varied between 0.06 % and 19.97 %.
Analysis of nicotinic acid and its metabolites by HPLC-MS/MS
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16008260
- 003
- CZ-PrNML
- 005
- 20160412133058.0
- 007
- ta
- 008
- 160320s2015 xr d f 000 0|cze||
- 009
- AR
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Žantová, Kamila $7 xx0206726 $u Univerzita Karlova v Praze, 1. lékařská fakulta, 4. interní klinika, U Nemocnice 2, Praha 2
- 245 10
- $a Stanovení nikotinové kyseliny a jejích metabolitů pomocí HPLC-MS/MS / $c K. Žantová, E. Tvrzická, M. Vecka, A. Žák
- 246 31
- $a Analysis of nicotinic acid and its metabolites by HPLC-MS/MS
- 504 __
- $a Literatura
- 520 9_
- $a Nicotinic acid is a hypolipidemic agent with pleiotropic effects. Its drug form with controlled release leads to pyridine metabolites associated with the risk of hepatotoxicity. The aim of the present study was to introduce a HPLC-MS method for the determination of nicotinic acid, nicotinamide, nicotinuric acid, N-methylnicotin¬amide, nicotinamide 1-oxide, 1-methyl-2-oxo-1,2-dihydro¬pyridine-5-carboxamide, and 1-methyl-4-oxo-1,4-dihydro¬pyridine-5-carboxamide in blood plasma or urine. The method is useful for the monitoring in hypolipidemic the¬rapy. We have compared calibration curves of individual metabolites using Hypercarb (graphite carbon) and Hypersil Silica (silicagel) columns. Both columns gave linear calibration curves for all the mentioned analytes (except for 1-methylnicotinamide) in the concentration range 102000 ng ml1. The calibration curve in blood plasma and urine measured with the Hypersil Silica column was linear in the range 204000 ng ml1 for all the tested analytes. The analysis time was 15 min with the column Hypercarb and 27 min with Hypersil Silica. Biological samples were extracted with sulfonated copolymer N-vinylpyrrolidone divinylbenzene. Reproducibility of the results for biological samples varied between 0.06 % and 19.97 %.
- 650 12
- $a chemické techniky analytické $7 D002623
- 650 _2
- $a niacin $x analýza $x farmakokinetika $x metabolismus $x škodlivé účinky $7 D009525
- 650 _2
- $a metody pro přípravu analytických vzorků $7 D053000
- 650 12
- $a vysokoúčinná kapalinová chromatografie $x metody $x přístrojové vybavení $x využití $7 D002851
- 650 12
- $a tandemová hmotnostní spektrometrie $x metody $x přístrojové vybavení $x využití $7 D053719
- 650 12
- $a kyseliny nikotinové $x analýza $x farmakokinetika $x metabolismus $x škodlivé účinky $7 D009539
- 650 _2
- $a krevní plazma $7 D010949
- 650 _2
- $a zdraví dobrovolníci pro lékařské studie $7 D064368
- 650 _2
- $a lidé $7 D006801
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Tvrzická, Eva $7 xx0076496 $u Univerzita Karlova v Praze, 1. lékařská fakulta, 4. interní klinika, U Nemocnice 2, Praha 2
- 700 1_
- $a Vecka, Marek, $d 1976- $7 xx0076497 $u Univerzita Karlova v Praze, 1. lékařská fakulta, 4. interní klinika, U Nemocnice 2, Praha 2
- 700 1_
- $a Žák, Aleš, $d 1951- $7 mzk2007382175 $u Univerzita Karlova v Praze, 1. lékařská fakulta, 4. interní klinika, U Nemocnice 2, Praha 2
- 773 0_
- $t Chemické listy $x 0009-2770 $g Roč. 109, č. 12 (2015), s. 950-956 $w MED00011010
- 856 41
- $u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/279/279 $y domovská stránka časopisu
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 4 $z 0
- 990 __
- $a 20160320160514 $b ABA008
- 991 __
- $a 20160412133142 $b ABA008
- 999 __
- $a ok $b bmc $g 1111486 $s 932601
- BAS __
- $a 3
- BMC __
- $a 2015 $b 109 $c 12 $d 950-956 $i 0009-2770 $m Chemické listy $n Chem. Listy $x MED00011010
- LZP __
- $c NLK137 $d 20160412 $a NLK 2016-13/dk