Monitoring of microscopic filamentous fungi in indoor air of transplant unit

O. Holý, I. Matoušková, A. Kubátová, P. Hamal, L. Svobodová, E. Jurásková, L. Raida

. 2015 ; 23 (4) : 331-334.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16013723

Digitální knihovna NLK
Zdroj

E-zdroje NLK Online Plný text

Free Medical Journals od 2004
ProQuest Central od 2009-03-01 do Před 6 měsíci
Medline Complete (EBSCOhost) od 2006-03-01 do Před 6 měsíci
Nursing & Allied Health Database (ProQuest) od 2009-03-01 do Před 6 měsíci
Health & Medicine (ProQuest) od 2009-03-01 do Před 6 měsíci
Public Health Database (ProQuest) od 2009-03-01 do Před 6 měsíci

AIM: The aim of the study was to control the microbial contamination of indoor air monitored monthly at the Transplant Unit of the University Hospital Olomouc from August 2010 to July 2011. METHODS: The unit is equipped with a three-stage air filtration system with HEPA filters. The MAS-100 air sampler (Merck, GER) was used. Twenty locations were singled out for the purposes of collecting a total of 720 samplings of the indoor air. Swabs of the HVAC diffusers at the sampling locations were always carried out after the sampling of the indoor air. RESULTS: In total, 480 samples of the indoor air were taken for Sabouraud chloramphenicol agar. In 11 cases (2.29%) the cultivation verified the presence of microscopic filamentous fungi. Only two cases involved the sanitary facilities of a patient isolation box; the other positive findings were from the facilities. The most frequent established genus was Aspergillus spp. (4x), followed by Trichoderma spp. (2x) and Penicillium spp. (2x), Paecilomyces spp., Eurotium spp., and Chrysonilia spp. (1x each). In 2 cases the cultivation established sterile aerial mycelium, unfortunately no further identification was possible. A total of 726 swabs of HVAC diffusers were collected (2 positive-0.28%). The study results demonstrated the efficacy of the HVAC equipment. CONCLUSIONS: With the continuing increase in the number of severely immunocompromised patients, hospitals are faced with the growing problem of invasive aspergillosis and other opportunistic infections. Preventive monitoring of microbial air contaminants is of major importance for the control of invasive aspergillosis.

000      
00000naa a2200000 a 4500
001      
bmc16013723
003      
CZ-PrNML
005      
20170918075820.0
007      
ta
008      
160506s2015 xr f 000 0|eng||
009      
AR
024    7_
$a 10.21101/cejph.a4062 $2 doi
035    __
$a (PubMed)26841147
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Holý, Ondřej $u Department of Preventive Medicine, Faculty of Medicine and Dentistry, Palacký University Olomouc, Olomouc, Czech Republic $7 xx0222173
245    10
$a Monitoring of microscopic filamentous fungi in indoor air of transplant unit / $c O. Holý, I. Matoušková, A. Kubátová, P. Hamal, L. Svobodová, E. Jurásková, L. Raida
520    9_
$a AIM: The aim of the study was to control the microbial contamination of indoor air monitored monthly at the Transplant Unit of the University Hospital Olomouc from August 2010 to July 2011. METHODS: The unit is equipped with a three-stage air filtration system with HEPA filters. The MAS-100 air sampler (Merck, GER) was used. Twenty locations were singled out for the purposes of collecting a total of 720 samplings of the indoor air. Swabs of the HVAC diffusers at the sampling locations were always carried out after the sampling of the indoor air. RESULTS: In total, 480 samples of the indoor air were taken for Sabouraud chloramphenicol agar. In 11 cases (2.29%) the cultivation verified the presence of microscopic filamentous fungi. Only two cases involved the sanitary facilities of a patient isolation box; the other positive findings were from the facilities. The most frequent established genus was Aspergillus spp. (4x), followed by Trichoderma spp. (2x) and Penicillium spp. (2x), Paecilomyces spp., Eurotium spp., and Chrysonilia spp. (1x each). In 2 cases the cultivation established sterile aerial mycelium, unfortunately no further identification was possible. A total of 726 swabs of HVAC diffusers were collected (2 positive-0.28%). The study results demonstrated the efficacy of the HVAC equipment. CONCLUSIONS: With the continuing increase in the number of severely immunocompromised patients, hospitals are faced with the growing problem of invasive aspergillosis and other opportunistic infections. Preventive monitoring of microbial air contaminants is of major importance for the control of invasive aspergillosis.
650    12
$a mikrobiologie vzduchu $7 D000391
650    _2
$a znečištění vzduchu ve vnitřním prostředí $x analýza $7 D016902
650    _2
$a infekce spojené se zdravotní péčí $x mikrobiologie $7 D003428
650    _2
$a monitorování životního prostředí $x metody $7 D004784
650    _2
$a houby $x izolace a purifikace $7 D005658
650    12
$a jednotky nemocniční $7 D006757
650    _2
$a nemocnice univerzitní $7 D006785
650    _2
$a imunosupresivní léčba $7 D007165
650    12
$a transplantace $7 D014180
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Matoušková, Ivanka $u Department of Preventive Medicine, Faculty of Medicine and Dentistry, Palacký University Olomouc, Olomouc, Czech Republic $7 mzk2005312998
700    1_
$a Kubátová, Alena, $u Department of Botany, Faculty of Science, Charles University, Prague, Czech Republic $d 1959- $7 uk2007351445
700    1_
$a Hamal, Petr $u Department of Microbiology, Faculty of Medicine, Palacký University Olomouc, Olomouc, Czech Republic $7 xx0060595
700    1_
$a Svobodová, Lucie $u Department of Microbiology, Faculty of Medicine, Palacký University Olomouc, Olomouc, Czech Republic $7 xx0145292
700    1_
$a Sedlatá Jurásková, Eva $7 xx0216171 $u Department of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University Olomouc, Olomouc, Czech Republic
700    1_
$a Raida, Luděk, $u Department of Haemato-Oncology, University Hospital Olomouc, Olomouc, Czech Republic $d 1968- $7 xx0034365
773    0_
$w MED00001083 $t Central European journal of public health $x 1210-7778 $g Roč. 23, č. 4 (2015), s. 331-334
856    41
$u http://apps.szu.cz/svi/cejph/ $y domovská stránka časopisu
910    __
$a ABA008 $b B 1829 $c 562 $y 4 $z 0
990    __
$a 20160506 $b ABA008
991    __
$a 20170918080434 $b ABA008
999    __
$a ok $b bmc $g 1126032 $s 938135
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 23 $c 4 $d 331-334 $i 1210-7778 $m Central European Journal of Public Health $n Cent. Eur. J. Public Health $x MED00001083
LZP    __
$b NLK118 $a Pubmed-20160506

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...