Je něco špatně v tomto záznamu ?
Leadless Cardiac Pacemakers: Pacing Paradigm Change
P. Neuzil, VY. Reddy,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, přehledy
- MeSH
- design vybavení MeSH
- implantované elektrody MeSH
- kardiostimulace umělá * metody MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- srdeční arytmie terapie MeSH
- studie proveditelnosti MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Traditional transvenous approach for permanent cardiac pacing can be associated with significant acute and chronic complications related partly to either the insertion of transvenous lead or subcutaneous placement of pacemaker device. We summarize the current status of a novel self-contained leadless cardiac pacemaker in the first-in-human and subsequent series of feasibility studies in patients indicated for ventricular rate-responsive pacing (VVI). Using a femoral venous approach, the device is implanted at the right ventricular apical septum region. We describe the technical and clinical characterization of this innovative technology. Two different systems of leadless pacemakers are currently implanted to the patients. Up to now, the electrical parameters, such as pacing thresholds, sensing parameters, and pacing impedances, either improved or remained stable within the accepted range. In this chapter, we also discuss the potential benefit for the future, but in summary, all available data demonstrate the feasibility of leadless cardiac pacing.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16020452
- 003
- CZ-PrNML
- 005
- 20160913112204.0
- 007
- ta
- 008
- 160722s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s11886-015-0619-3 $2 doi
- 024 7_
- $a 10.1007/s11886-015-0619-3 $2 doi
- 035 __
- $a (PubMed)26233700
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Neuzil, Petr $u Cardiology Department, Na Homolce Hospital, Prague, Czech Republic, pneuzil@seznam.cz.
- 245 10
- $a Leadless Cardiac Pacemakers: Pacing Paradigm Change / $c P. Neuzil, VY. Reddy,
- 520 9_
- $a Traditional transvenous approach for permanent cardiac pacing can be associated with significant acute and chronic complications related partly to either the insertion of transvenous lead or subcutaneous placement of pacemaker device. We summarize the current status of a novel self-contained leadless cardiac pacemaker in the first-in-human and subsequent series of feasibility studies in patients indicated for ventricular rate-responsive pacing (VVI). Using a femoral venous approach, the device is implanted at the right ventricular apical septum region. We describe the technical and clinical characterization of this innovative technology. Two different systems of leadless pacemakers are currently implanted to the patients. Up to now, the electrical parameters, such as pacing thresholds, sensing parameters, and pacing impedances, either improved or remained stable within the accepted range. In this chapter, we also discuss the potential benefit for the future, but in summary, all available data demonstrate the feasibility of leadless cardiac pacing.
- 650 _2
- $a srdeční arytmie $x terapie $7 D001145
- 650 12
- $a kardiostimulace umělá $x metody $7 D002304
- 650 _2
- $a implantované elektrody $7 D004567
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a studie proveditelnosti $7 D005240
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a kardiostimulátor $7 D010138
- 650 _2
- $a výsledek terapie $7 D016896
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Reddy, Vivek Y
- 773 0_
- $w MED00189517 $t Current cardiology reports $x 1534-3170 $g Roč. 17, č. 8 (2015), s. 68
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26233700 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160722 $b ABA008
- 991 __
- $a 20160913112522 $b ABA008
- 999 __
- $a ok $b bmc $g 1155122 $s 944980
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 17 $c 8 $d 68 $i 1534-3170 $m Current cardiology reports $n Curr Cardiol Rep $x MED00189517
- LZP __
- $a Pubmed-20160722