Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Leadless Cardiac Pacemakers: Pacing Paradigm Change

P. Neuzil, VY. Reddy,

. 2015 ; 17 (8) : 68.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc16020452

Traditional transvenous approach for permanent cardiac pacing can be associated with significant acute and chronic complications related partly to either the insertion of transvenous lead or subcutaneous placement of pacemaker device. We summarize the current status of a novel self-contained leadless cardiac pacemaker in the first-in-human and subsequent series of feasibility studies in patients indicated for ventricular rate-responsive pacing (VVI). Using a femoral venous approach, the device is implanted at the right ventricular apical septum region. We describe the technical and clinical characterization of this innovative technology. Two different systems of leadless pacemakers are currently implanted to the patients. Up to now, the electrical parameters, such as pacing thresholds, sensing parameters, and pacing impedances, either improved or remained stable within the accepted range. In this chapter, we also discuss the potential benefit for the future, but in summary, all available data demonstrate the feasibility of leadless cardiac pacing.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020452
003      
CZ-PrNML
005      
20160913112204.0
007      
ta
008      
160722s2015 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s11886-015-0619-3 $2 doi
024    7_
$a 10.1007/s11886-015-0619-3 $2 doi
035    __
$a (PubMed)26233700
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Neuzil, Petr $u Cardiology Department, Na Homolce Hospital, Prague, Czech Republic, pneuzil@seznam.cz.
245    10
$a Leadless Cardiac Pacemakers: Pacing Paradigm Change / $c P. Neuzil, VY. Reddy,
520    9_
$a Traditional transvenous approach for permanent cardiac pacing can be associated with significant acute and chronic complications related partly to either the insertion of transvenous lead or subcutaneous placement of pacemaker device. We summarize the current status of a novel self-contained leadless cardiac pacemaker in the first-in-human and subsequent series of feasibility studies in patients indicated for ventricular rate-responsive pacing (VVI). Using a femoral venous approach, the device is implanted at the right ventricular apical septum region. We describe the technical and clinical characterization of this innovative technology. Two different systems of leadless pacemakers are currently implanted to the patients. Up to now, the electrical parameters, such as pacing thresholds, sensing parameters, and pacing impedances, either improved or remained stable within the accepted range. In this chapter, we also discuss the potential benefit for the future, but in summary, all available data demonstrate the feasibility of leadless cardiac pacing.
650    _2
$a srdeční arytmie $x terapie $7 D001145
650    12
$a kardiostimulace umělá $x metody $7 D002304
650    _2
$a implantované elektrody $7 D004567
650    _2
$a design vybavení $7 D004867
650    _2
$a studie proveditelnosti $7 D005240
650    _2
$a lidé $7 D006801
650    12
$a kardiostimulátor $7 D010138
650    _2
$a výsledek terapie $7 D016896
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Reddy, Vivek Y
773    0_
$w MED00189517 $t Current cardiology reports $x 1534-3170 $g Roč. 17, č. 8 (2015), s. 68
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26233700 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20160913112522 $b ABA008
999    __
$a ok $b bmc $g 1155122 $s 944980
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 17 $c 8 $d 68 $i 1534-3170 $m Current cardiology reports $n Curr Cardiol Rep $x MED00189517
LZP    __
$a Pubmed-20160722

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...