EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation

J. Kautzner, P. Neuzil, H. Lambert, P. Peichl, J. Petru, R. Cihak, J. Skoda, D. Wichterle, E. Wissner, A. Yulzari, KH. Kuck,

. 2015 ; 17 (8) : 1229-35. [pub] 20150603

Language English Country England, Great Britain

Document type Controlled Clinical Trial, Journal Article, Multicenter Study, Research Support, Non-U.S. Gov't

AIMS: A challenge of pulmonary vein isolation (PVI) in catheter ablation for paroxysmal atrial fibrillation (PAF) is electrical reconnection of the PV. EFFICAS I showed correlation between contact force (CF) parameters and PV durable isolation but no prospective evaluation was made. EFFICAS II was a multicentre study to prospectively assess the impact of CF guidance for an effective reduction of PVI gaps. METHODS AND RESULTS: Pulmonary vein isolation using a radiofrequency (RF) ablation catheter with an integrated force sensor (TactiCathTM) was performed in patients with PAF. Operators were provided EFFICAS I-based CF guidelines [target 20 g, range 10-30 g, minimum 400 g s force-time integral (FTI)]. Conduction gaps were assessed by remapping of PVs after 3 months, and gap rate was compared with EFFICAS I outcome. At follow up, 24 patients had 85% of PVs remaining isolated, compared with 72% in EFFICAS I (P = 0.037) in which CF guidelines were not used. The remaining 15% of gaps correlated to the number of catheter moves at creating the PVI line, quantified as Continuity Index. For PV lines with contiguous lesions and low catheter moves, durable isolation was 81% in EFFICAS I and 98% in EFFICAS II (P = 0.005). At index procedure, the number of lesions was reduced by 15% in EFFICAS II vs. EFFICAS I. CONCLUSION: The use of CF with the above guidelines and contiguous deployment of RF lesions in EFFICAS II study resulted in more durable PVI in catheter ablation of PAF.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020709
003      
CZ-PrNML
005      
20220526090225.0
007      
ta
008      
160722s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/europace/euv057 $2 doi
024    7_
$a 10.1093/europace/euv057 $2 doi
035    __
$a (PubMed)26041872
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Kautzner, Josef $u Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, Prague 14201, Czech Republic josef.kautzner@ikem.cz.
245    10
$a EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation / $c J. Kautzner, P. Neuzil, H. Lambert, P. Peichl, J. Petru, R. Cihak, J. Skoda, D. Wichterle, E. Wissner, A. Yulzari, KH. Kuck,
520    9_
$a AIMS: A challenge of pulmonary vein isolation (PVI) in catheter ablation for paroxysmal atrial fibrillation (PAF) is electrical reconnection of the PV. EFFICAS I showed correlation between contact force (CF) parameters and PV durable isolation but no prospective evaluation was made. EFFICAS II was a multicentre study to prospectively assess the impact of CF guidance for an effective reduction of PVI gaps. METHODS AND RESULTS: Pulmonary vein isolation using a radiofrequency (RF) ablation catheter with an integrated force sensor (TactiCathTM) was performed in patients with PAF. Operators were provided EFFICAS I-based CF guidelines [target 20 g, range 10-30 g, minimum 400 g s force-time integral (FTI)]. Conduction gaps were assessed by remapping of PVs after 3 months, and gap rate was compared with EFFICAS I outcome. At follow up, 24 patients had 85% of PVs remaining isolated, compared with 72% in EFFICAS I (P = 0.037) in which CF guidelines were not used. The remaining 15% of gaps correlated to the number of catheter moves at creating the PVI line, quantified as Continuity Index. For PV lines with contiguous lesions and low catheter moves, durable isolation was 81% in EFFICAS I and 98% in EFFICAS II (P = 0.005). At index procedure, the number of lesions was reduced by 15% in EFFICAS II vs. EFFICAS I. CONCLUSION: The use of CF with the above guidelines and contiguous deployment of RF lesions in EFFICAS II study resulted in more durable PVI in catheter ablation of PAF.
650    _2
$a dospělí $7 D000328
650    _2
$a fibrilace síní $x diagnóza $x chirurgie $7 D001281
650    _2
$a mapování potenciálů tělesného povrchu $x přístrojové vybavení $x metody $7 D018780
650    _2
$a katetrizační ablace $x přístrojové vybavení $x metody $7 D017115
650    _2
$a design vybavení $7 D004867
650    _2
$a analýza selhání vybavení $7 D019544
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a převodní systém srdeční $x chirurgie $7 D006329
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a venae pulmonales $x chirurgie $7 D011667
650    _2
$a mechanický stres $7 D013314
650    _2
$a chirurgie s pomocí počítače $x přístrojové vybavení $x metody $7 D025321
650    _2
$a měniče tlakové $7 D014160
650    _2
$a výsledek terapie $7 D016896
651    _2
$a Evropa $7 D005060
655    _2
$a klinické zkoušky kontrolované $7 D018848
655    _2
$a časopisecké články $7 D016428
655    _2
$a multicentrická studie $7 D016448
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Neuzil, Petr $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic.
700    1_
$a Lambert, Hendrik $u St Jude Medical GVA, Geneva, Switzerland.
700    1_
$a Peichl, Petr, $u Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, Prague 14201, Czech Republic. $d 1976- $7 xx0092197
700    1_
$a Petru, Jan $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic.
700    1_
$a Cihak, Robert $u Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, Prague 14201, Czech Republic.
700    1_
$a Skoda, Jan $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic.
700    1_
$a Wichterle, Dan $u Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, Prague 14201, Czech Republic.
700    1_
$a Wissner, Erik $u Abt Kardiologie, Asklepios Klinik St. Georg, Hamburg, Germany.
700    1_
$a Yulzari, Aude $u St Jude Medical GVA, Geneva, Switzerland.
700    1_
$a Kuck, Karl-Heinz, $u Abt Kardiologie, Asklepios Klinik St. Georg, Hamburg, Germany. $d 1952- $7 xx0273250
773    0_
$w MED00149837 $t Europace European pacing, arrhythmias, and cardiac electrophysiology journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology $x 1532-2092 $g Roč. 17, č. 8 (2015), s. 1229-35
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26041872 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20220526090219 $b ABA008
999    __
$a ok $b bmc $g 1155379 $s 945237
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 17 $c 8 $d 1229-35 $e 20150603 $i 1532-2092 $m Europace $n Europace $x MED00149837
LZP    __
$a Pubmed-20160722

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...